A low tilt waveform in the transthoracic defibrillation of ventricular arrhythmias during cardiac arrest

被引:3
作者
Darragh, K. M. [1 ,2 ]
Manoharan, G. [1 ,2 ,3 ]
Di Maio, R. [3 ]
Stevenson, M. [2 ]
Bennett, J. R. [1 ,2 ]
Walsh, S. J. [1 ,2 ]
Allen, J. D. [2 ]
Anderson, J. Mc. C. [3 ]
Adgey, A. A. J. [1 ,2 ,3 ]
机构
[1] Royal Victoria Hosp, Ctr Heart, Belfast BT12 6BA, Antrim, North Ireland
[2] Queens Univ Belfast, Belfast, Antrim, North Ireland
[3] Univ Ulster, No Ireland Bioengn Ctr, Jordanstown, North Ireland
关键词
Ventricular fibrillation; Defibrillation; Low tilt; Waveform; IMPLANTABLE ATRIAL DEFIBRILLATOR; TRANSVENOUS CARDIOVERSION; STRENGTH-DURATION; FIBRILLATION; EFFICACY; RESUSCITATION; MULTICENTER; WAVEFORMS; SUCCESS; CURVES;
D O I
10.1016/j.resuscitation.2012.04.018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim: Most commercially available defibrillators utilise a high tilt waveform. Work in atrial fibrillation has shown improved defibrillation success using low tilt waveforms. We hypothesise that a novel low tilt biphasic waveform will be non-inferior to a standard tilt waveform whilst delivering lower energy for the defibrillation of ventricular arrhythmias. Methods: Patients in cardiac arrest who experienced ventricular arrhythmias received shocks from a novel low tilt waveform defibrillator at 120J or a standard tilt waveform defibrillator at 150J. Resuscitation guidelines were followed as per Resuscitation Council UK, 2005. A shock was successful when the ventricular arrhythmia was terminated for >= 5 s following shock delivery. Results: A total of 113 cardiac arrest cases were included. The low tilt device was used for 56 cases and the standard tilt device for 57 cases. The presenting rhythm was ventricular fibrillation (VF) in 71.7% (81/113), pulseless electrical activity (PEA) in 15.9% (18/113), ventricular tachycardia (VT) in 9.7% (11/113), asystole in 1.8% (2/113) and narrow complex rhythm in 0.9% (1/113). The low tilt device resulted in first shock success in 86% (48/56 cases) vs. the standard tilt device first shock success of 77% (44/57 cases). There was no significant difference in first shock success between the two devices (p = 0.36). Conclusion: The low tilt waveform used in this study demonstrated first shock success rates in keeping with a commercially available high tilt defibrillator which could result in less myocardial damage due to reduced energy requirements. Crown Copyright (C) 2012 Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1438 / 1443
页数:6
相关论文
共 24 条
[1]   STRENGTH-DURATION CURVES OF FIXED PULSE WIDTH VARIABLE TILT TRUNCATED EXPONENTIAL WAVEFORMS FOR NONTHORACOMY INTERNAL DEFIBRILLATION IN DOGS [J].
CHAPMAN, PD ;
WETHERBEE, JN ;
VETTER, JW ;
TROUP, P ;
SOUZA, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (07) :1045-1050
[2]  
Darragh KM, 2007, EUROPACE, V9, pii4
[3]   European Resuscitation Council Guidelines for Resuscitation 2010 Section 3 Electrical therapies Automated external defibrillators, defibrillation, cardioversion and pacing [J].
Deakin, Charles D. ;
Nolan, Jerry P. ;
Sunde, Kjetil ;
Koster, Rudolph W. .
RESUSCITATION, 2010, 81 (10) :1293-1304
[4]  
Department of health policy and guidance, TAK HEALTHC PAT TRAN
[5]   STRENGTH DURATION AND PROBABILITY OF SUCCESS CURVES FOR DEFIBRILLATION WITH BIPHASIC WAVE-FORMS [J].
FEESER, SA ;
TANG, ASL ;
KAVANAGH, KM ;
ROLLINS, DL ;
SMITH, WM ;
WOLF, PD ;
IDEKER, RE .
CIRCULATION, 1990, 82 (06) :2128-2141
[6]  
Gliner Bradford E., 1998, Biomedical Instrumentation and Technology, V32, P631
[7]   A pilot study of a low-tilt biphasic waveform for transvenous cardioversion of atrial fibrillation: Improved efficacy compared with conventional capacitor-based waveforms in patients [J].
Glover, Benedict M. ;
McCann, Conor J. ;
Manoharan, Ganesh ;
Walsh, Simon J. ;
Moore, Michael J. ;
Allen, James D. ;
Escalona, Omar ;
Anderson, John Mcc. ;
Trouton, Tom G. ;
Stevenson, Mike ;
Roberts, Michael J. ;
Adgey, Jennifer AA. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (08) :1020-1024
[8]   Rounded biphasic waveform reduces energy requirements for transvenous catheter cardioversion of atrial fibrillation and flutter [J].
Harbinson, MT ;
Allen, JD ;
Imam, Z ;
Dempsey, G ;
Anderson, JM ;
Ayers, GM ;
Adgey, AAJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :226-229
[9]   Performance of a rectilinear biphasic waveform in defibrillation of presenting and recurrent ventricular fibrillation: A prospective multicenter study [J].
Hess, Erik P. ;
Agarwal, Dipti ;
Myers, Lucas A. ;
Atkinson, Elizabeth J. ;
White, Roger D. .
RESUSCITATION, 2011, 82 (06) :685-689
[10]   OPTIMAL TRUNCATION OF DEFIBRILLATION PULSES [J].
IRNICH, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (04) :673-688