Transfer of porcine endogenous retrovirus across hollow fiber membranes - Significance to a bioartificial liver

被引:62
|
作者
Nyberg, SL
Hibbs, JR
Hardin, JA
Germer, JJ
Persing, DH
机构
[1] Mayo Clin & Mayo Fdn, Dept Surg, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Pathol & Lab Med, Rochester, MN 55905 USA
关键词
D O I
10.1097/00007890-199905150-00009
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. A porcine endogenous retrovirus (PERV*) capable of infecting human cells has been identified. This study was designed to determine whether hollow fiber membranes, such as those used in a bioartificial liver, block the transfer of PERV. Methods. Three hollow fiber cartridges (HFCs) were studied in duplicate: cellulose fibers with 70 kD nominal molecular weight cut-off (MWCO), polysulfone fibers with 400 kD MWCO, and mixed cellulose fibers with 200 nm porosity. PK15 cells (porcine kidney cell line), known to produce PERV, were grown in the intraluminal compartment of HFCs fiber cartridges. Samples of medium were collected from both intraluminal and extraluminal compartments of the HFCs fiber cartridge during 14 days of culture. Samples were screened for PERV using reverse transcription polymerase chain reaction. All positive samples were tested for PERV infectivity in human 293 cells. Results. PERV was detected in all samples from the intraluminal space and all intraluminal samples seemed to infect 293 cells. All extraluminal samples from the fibers of 200 nm porosity tested positive for PERV, Detection of PERV in the extraluminal space was delayed by fibers of 400 MD MWCO and 70 kD MWCO until at least day 3 and day 7, respectively, after inoculation of PK15 cells. Positive extraluminal samples from fibers of 400 kD MWCO and 70 kD MWCO did not infect 293 cells, Conclusion. Pore size, membrane composition, and duration of exposure influenced the transfer of PERV across HFCs, Some HFCs decrease the risk of viral exposure to patients during bioartificial liver therapy.
引用
收藏
页码:1251 / 1255
页数:5
相关论文
共 50 条
  • [41] A gel-entrapment hollow fiber bioartificial liver employing xenogeneic hepatocytes
    Hu, WS
    Friend, JR
    Wu, FJ
    Remmel, RP
    Cerra, FB
    TISSUE ENGINEERING FOR THERAPEUTIC USE 1, 1998, 1169 : 119 - 126
  • [42] EVALUATION OF A HEPATOCYTE-ENTRAPMENT HOLLOW FIBER BIOREACTOR - A POTENTIAL BIOARTIFICIAL LIVER
    NYBERG, SL
    SHATFORD, RA
    PESHWA, MV
    WHITE, JG
    CERRA, FB
    HU, WS
    BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (02) : 194 - 203
  • [43] Bifunctional Polysulfone-Chitosan Composite Hollow Fiber Membrane for Bioartificial Liver
    Teotia, Rohit S.
    Kalila, Dhrubajyoti
    Singh, Atul K.
    Verma, Surendra K.
    Kadam, Sachin S.
    Bellare, Jayesh R.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2015, 1 (06): : 372 - 381
  • [44] Distributions of pressure and flow rate in a hollow-fiber membrane bioartificial liver
    Yoshikawa, S
    Ogihara, S
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2005, 38 (09) : 684 - 687
  • [45] Analysis of mass transfer in hollow-fiber membranes
    Nagy, E
    Hadik, P
    DESALINATION, 2002, 145 (1-3) : 147 - 152
  • [46] Twisted hollow fiber membranes for enhanced mass transfer
    Motevalian, Seyed Pouria
    Borhan, Ali
    Zhou, Hongyi
    Zydney, Andrew
    JOURNAL OF MEMBRANE SCIENCE, 2016, 514 : 586 - 594
  • [47] Mass transfer in forward osmosis with hollow fiber membranes
    Lin, Shihong
    JOURNAL OF MEMBRANE SCIENCE, 2016, 514 : 176 - 185
  • [48] DEVELOPMENT OF A BIOARTIFICIAL LIVER - PROPERTIES AND FUNCTION OF A HOLLOW-FIBER MODULE INOCULATED WITH LIVER-CELLS
    ROZGA, J
    WILLIAMS, F
    RO, MS
    NEUZIL, DF
    GIORGIO, TD
    BACKFISCH, G
    MOSCIONI, AD
    HAKIM, R
    DEMETRIOU, AA
    HEPATOLOGY, 1993, 17 (02) : 258 - 265
  • [49] Hollow fiber bioartificial liver: Physical and biological characterization with C3A cells
    Gautier, Aude
    Ould-Dris, Aissa
    Dufresne, Murielle
    Paullier, Patrick
    Von Harten, Bodo
    Lernke, Horst-Dieter
    Legallais, Cecile
    JOURNAL OF MEMBRANE SCIENCE, 2009, 341 (1-2) : 203 - 213
  • [50] Evaluation of the mass transfer rate using computer simulation in a three-dimensional interwoven hollow fiber-type bioartificial liver
    Sakiyama, Ryoichi
    Hamada, Hiroyuki
    Blau, Brandon
    Freyer, Nora
    Zeilinger, Katrin
    Schubert, Frank
    Miki, Toshio
    BIOTECHNOLOGY LETTERS, 2018, 40 (11-12) : 1567 - 1578