The results of MR angiography at 1.0 T with digital intraarterial angiography in the screening of patients with suspected renal hypertension were compared. In the first phase of the study, 10 volunteers underwent examination with both two-dimensional (2D) with traveling saturation time-of-flight (TOF) magnetic resonance angiography (MRA) with various parameters to develop a protocol for evaluation of the renal arteries, In the second phase, 36 patients with suspected renovascular hypertension underwent both 2D TOF MRA and intraarterial digital angiography to evaluate the clinical value of MRA. The degree of stenosis was graded with a two-point scale, In volunteers, using 2D acquisitions, C/N ratios indicated the best flip angle as being 55 degrees (p = .02), MRA showed 100% (70/70) of all main arteries and 86% (6/7) of all accessory renal arteries seen on angiography, MRA had a sensitivity of 94% (15/16) and a specificity of 98% (60/61) for detection of stenoses of greater than 50% present in 14 patients. 2D-TOF MRA at 1.0 T shows promise in the noninvasive diagnosis of patients with suspected renovascular hypertension. Copyright (C) 1996 Elsevier Science Inc.
引用
收藏
页码:1033 / 1041
页数:9
相关论文
共 50 条
  • [21] Gadolinium-enhanced 3D MR angiography of renal artery stenosis: A pilot comparison of maximum intensity projection, multiplanar reformatting, and 3D volume-rendering postprocessing algorithms
    Baskaran, V
    Pereles, FS
    Nemcek, AA
    Carr, JC
    Miller, FH
    Ly, J
    Krupinski, E
    Finn, JP
    ACADEMIC RADIOLOGY, 2002, 9 (01) : 50 - 59
  • [22] Renal artery stenosis: CT angiography - Comparison of real-time volume-rendering and maximum intensity projection algorithms
    Johnson, PT
    Halpern, EJ
    Kuszyk, BS
    Heath, DG
    Wechsler, RJ
    Nazarian, LN
    Gardiner, GA
    Levin, DC
    Fishman, EK
    RADIOLOGY, 1999, 211 (02) : 337 - 343
  • [23] Magnetic resonance angiography of the carotid artery: artifacts, anatomy, diseases
    Bousson, V
    Levy, C
    Brunereau, L
    Marsot-Dupuch, K
    Pradel, C
    Tubiana, JM
    JOURNAL DE RADIOLOGIE, 1998, 79 (08): : 723 - 741
  • [24] ASSESSMENT OF VASCULAR INVOLVEMENT WITH MAGNETIC-RESONANCE ANGIOGRAPHY (MRA) IN PANCOAST SYNDROME
    LAISSY, JP
    SOYER, P
    SEKKAL, SR
    TEBBOUNE, D
    SERVOIS, V
    SIBERT, A
    MENU, Y
    MAGNETIC RESONANCE IMAGING, 1995, 13 (04) : 523 - 530
  • [25] MR-guided PTA in experimental bilateral rabbit renal artery stenosis and MR angiography follow-up versus histomorphometry
    Le Blanche, AF
    Rossert, J
    Wassef, M
    Lévy, B
    Bigot, JM
    Boudghene, F
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (05) : 368 - 374
  • [26] STENOSIS OF THE RENAL-ARTERY - ASSESSMENT OF SLOWED SYSTOLE IN THE DOWNSTREAM CIRCULATION WITH DOPPLER SONOGRAPHY
    PATRIQUIN, HB
    LAFORTUNE, M
    JEQUIER, JC
    OREGAN, S
    GAREL, L
    LANDRIAULT, J
    FONTAINE, A
    FILIATRAULT, D
    RADIOLOGY, 1992, 184 (02) : 479 - 485
  • [27] Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Mellone, R
    Angeli, E
    Venturini, M
    Garancini, MP
    Quartagno, R
    Bianchi, G
    DelMaschio, A
    RADIOLOGY, 1997, 205 (03) : 689 - 695
  • [28] RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS
    BERLAND, LL
    KOSLIN, DB
    ROUTH, WD
    KELLER, FS
    RADIOLOGY, 1990, 174 (02) : 421 - 423
  • [29] Detection of renal artery stenosis: Potentials and limits of Doppler waveform analysis in intrarenal vessels in comparison with angiography.
    Stuhrmann, M
    Roefke, C
    Jahnke, T
    Cramer, BM
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (03): : 258 - 263
  • [30] Multidetector-row CT angiography of renal artery stenosis in 50 consecutive patients: prospective interobserver comparison with DSA
    Fraioli, F
    Catalano, C
    Bertoletti, L
    Danti, M
    Fanelli, F
    Napoli, A
    Cavacece, M
    Passariello, R
    RADIOLOGIA MEDICA, 2006, 111 (03): : 459 - 468