Diffusion-tensor MRI reveals the complex muscle architecture of the human forearm

被引:102
作者
Froeling, Martijn [1 ,2 ]
Nederveen, Aart J. [1 ]
Heijtel, Dennis F. R. [1 ,2 ]
Lataster, Arno [3 ]
Bos, Clemens [4 ]
Nicolay, Klaas [2 ]
Maas, Mario [1 ]
Drost, Maarten R. [5 ]
Strijkers, Gustav J. [2 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[2] Eindhoven Univ Technol, Biomed NMR, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[3] Maastricht Univ, Dept Anat & Embryol, Maastricht, Netherlands
[4] Philips Med Syst, Best, Netherlands
[5] Maastricht Univ, Dept Human Movement Sci, Sch Nutr Toxicol & Metab, Maastricht, Netherlands
关键词
diffusion tensor imaging; skeletal muscle architecture; forearm; segmentation; HUMAN SKELETAL-MUSCLE; FIBER TRACKING; MAGNETIC-RESONANCE; IN-VIVO; CALF MUSCLE; IMAGES; NOISE; REPRODUCIBILITY; CONTRACTION; RELAXATION;
D O I
10.1002/jmri.23608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design a time-efficient patient-friendly clinical diffusion tensor MRI protocol and postprocessing tool to study the complex muscle architecture of the human forearm. Materials and Methods: The 15-minute examination was done using a 3 T system and consisted of: T1-weighted imaging, dual echo gradient echo imaging, single-shot spin-echo echo-planar imaging (EPI) diffusion tensor MRI. Postprocessing comprised of signal-to-noise improvement by a Rician noise suppression algorithm, image registration to correct for motion and eddy currents, and correction of susceptibility-induced deformations using magnetic field inhomogeneity maps. Per muscle one to five regions of interest were used for fiber tractography seeding. To validate our approach, the reconstructions of individual muscles from the in vivo scans were compared to photographs of those dissected from a human cadaver forearm. Results: Postprocessing proved essential to allow muscle segmentation based on combined T1-weighted and diffusion tensor data. The protocol can be applied more generally to study human muscle architecture in other parts of the body. Conclusion: The proposed protocol was able to visualize the muscle architecture of the human forearm in great detail and showed excellent agreement with the dissected cadaver muscles. J. Magn. Reson. Imaging 2012;36:237248. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:237 / 248
页数:12
相关论文
共 51 条
  • [1] Aja-Fernández S, 2008, IEEE T MED IMAGING, V27, P1389, DOI 10.1109/TMI.2008.920609
  • [2] Spatial transformations of diffusion tensor magnetic resonance images
    Alexander, DC
    Pierpaoli, C
    Basser, PJ
    Gee, JC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (11) : 1131 - 1139
  • [3] A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii
    Blemker, SS
    Pinsky, PM
    Delp, SL
    [J]. JOURNAL OF BIOMECHANICS, 2005, 38 (04) : 657 - 665
  • [4] In vivo MR tractography of thigh muscles using diffusion imaging: initial results
    Budzik, J. F.
    Le Thuc, V.
    Demondion, X.
    Morel, M.
    Chechin, D.
    Cotten, A.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (12) : 3079 - 3085
  • [5] RELATIONSHIP BETWEEN MUSCLE-FIBER TYPES AND SIZES AND MUSCLE ARCHITECTURAL PROPERTIES IN THE MOUSE HINDLIMB
    BURKHOLDER, TJ
    FINGADO, B
    BARON, S
    LIEBER, RL
    [J]. JOURNAL OF MORPHOLOGY, 1994, 221 (02) : 177 - 190
  • [6] Chen NK, 1999, MAGNET RESON MED, V41, P1206, DOI 10.1002/(SICI)1522-2594(199906)41:6<1206::AID-MRM17>3.0.CO
  • [7] 2-L
  • [8] Validation of diffusion tensor MRI-based muscle fiber tracking
    Damon, BM
    Ding, ZH
    Anderson, AW
    Freyer, AS
    Gore, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 97 - 104
  • [9] Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations
    Damon, Bruce M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) : 934 - 944
  • [10] Assessment of calf muscle contraction by diffusion tensor imaging
    Deux, J. F.
    Malzy, P.
    Paragios, N.
    Bassez, G.
    Luciani, A.
    Zerbib, P.
    Roudot-Thoraval, F.
    Vignaud, A.
    Kobeiter, H.
    Rahmouni, A.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (10) : 2303 - 2310