Assessment of rapid diagnostic tests and fourth-generation Enzyme-Linked Immunosorbent Assays in the screening of Human Immunodeficiency and Hepatitis B virus infections among first-time blood donors in Libreville (Gabon)

被引:7
|
作者
Mba, Jean Marie Eko [1 ,2 ]
Bisseye, Cyrille [2 ]
Mombo, Landry Erik [2 ]
Ndong, Jophrette Mireille Ntsame [1 ]
Ekayeng, Schella Carlaye Mbina [1 ,2 ]
Bengone, Calixte [1 ]
M'batchi, Bertrand [2 ]
Nagalo, Bolni Marius [2 ,3 ]
机构
[1] CNTS, Libreville, Gabon
[2] Univ Sci & Tech Masuku, Lab Biol Mol & Cellulaire, Franceville, Gabon
[3] Mayo Clin Scottsdale, Dept Hematol Oncol, Scottsdale, AZ USA
关键词
hepatitis B surface antigen; human immunodeficiency virus; Libreville; rapid detection test; sensitivity; TRANSMITTED VIRAL-INFECTIONS; TRANSFUSION SAFETY; HIV-INFECTION; RISK; PERFORMANCE;
D O I
10.1002/jcla.22824
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Blood transfusion is a pathway for the transmission of blood-borne pathogens such as human immunodeficiency virus (HIV) and hepatitis B virus (HBV) from donors to recipients in most countries in sub-Saharan Africa, including Gabon. The study aimed to compare the performance of four rapid diagnostic tests (RDTs: Alere DETERMINE, BIOSYNEX Exacto Pro HIV, MEDIFF HIV 1&2, and BIOSYNEX IMMUNOQUICK HBsAg) with results of 4th-generation immunoenzymatic assays COBAS 6000 e601 and EVOLIS BioRad for the detection of HIV and hepatitis B surface antigen (HBsAg) in blood donors in Libreville, Gabon. Methods Reactive and nonreactive blood samples for HIV and HBsAg were selected using fourth-generation ELISA COBAS 6000 e601 and EVOLIS BioRad. The sensitivities of RDTs were calculated using Epi Info version 6.04dfr (CDC, Atlanta, USA). Results Sensitivities for the detection of HIV in blood donors were 90.9% for Alere DETERMINE, 81.8% for BIOSYNEX Exacto Pro HIV, and 81.8% for MEDIFF HIV 1&2 Serum/sang Total Cassette compared with COBAS 6000 e601. The sensitivity of Alere DETERMINE compared to the semi-automated ELISA Bio-Rad for HIV detection was 65.6%. The sensitivity of BIOSYNEX IMMUNOQUICK HBsAg compared to ELISA tests for the detection of HBsAg was 78.0%. The specificity of all RDTs for the detection of HIV and HBsAg was 100%. Conclusion Alere DETERMINE HIV-1/2, MEDIFF HIV 1&2 Serum/sang Total Cassette, BIOSYNEX Exacto Pro HIV, and BIOSYNEX IMMUNOQUICK HBsAg are not recommended for determining whether donors qualify to donate blood because of their low sensitivity for the detection of HIV antibodies and HBsAg in blood donors in Gabon.
引用
收藏
页数:6
相关论文
共 3 条
  • [1] Seroprevalence of Hepatitis B, Hepatitis C, and human immunodeficiency virus among healthy voluntary first-time blood donors in Kolkata
    Das, B. K.
    Gayen, B. K.
    Aditya, Subhra
    Chakrovorty, Sumit Kumar
    Datta, P. K.
    Joseph, Ajay
    ANNALS OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2011, 4 (02) : 86 - 90
  • [2] EFFECT OF SWITCHING FROM 1ST-GENERATION TO 2ND-GENERATION ENZYME-LINKED IMMUNOSORBENT ASSAYS ON SCREENING FOR HUMAN-IMMUNODEFICIENCY-VIRUS ANTIBODY
    MORRIS, DJ
    CORBITT, G
    CROSDALE, E
    SERODIAGNOSIS AND IMMUNOTHERAPY IN INFECTIOUS DISEASE, 1990, 4 (03) : 217 - 220
  • [3] Combining rapid diagnostic tests and dried blood spot assays for point-of-care testing of human immunodeficiency virus, hepatitis B and hepatitis C infections in Burkina Faso, West Africa
    Kania, D.
    Bekale, A. M.
    Nagot, N.
    Mondain, A. -M.
    Ottomani, L.
    Meda, N.
    Traore, M.
    Ouedraogo, J. B.
    Ducos, J.
    Van de Perre, P.
    Tuaillon, E.
    CLINICAL MICROBIOLOGY AND INFECTION, 2013, 19 (12) : E533 - E541