The amount of keratinized mucosa may not influence peri-implant health in compliant patients: A retrospective 5-year analysis

被引:47
|
作者
Lim, Hyun-Chang [1 ,2 ]
Wiedemeier, Daniel B. [3 ]
Hammerle, Christoph H. F. [1 ]
Thoma, Daniel S. [1 ]
机构
[1] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
[2] Kyung Hee Univ, Sch Dent, Periodontal Implant Clin Res Inst, Dept Periodontol, Seoul, South Korea
[3] Univ Zurich, Ctr Dent Med, Stat Serv, Zurich, Switzerland
关键词
dental implant; keratinized mucosa; peri-implant diseases; XENOGENEIC COLLAGEN MATRIX; SOFT-TISSUE AUGMENTATION; DENTAL IMPLANTS; ATTACHED GINGIVA; RISK INDICATORS; FOLLOW-UP; WIDTH; PROSTHESES; DISEASE; ASSOCIATION;
D O I
10.1111/jcpe.13078
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim (a) To investigate the influence of the keratinized mucosa (KM) on peri-implant health or disease and (b) to identify a threshold value for the width of KM for peri-implant health. Materials and Methods The total dataset was subsampled, that is one implant was randomly chosen per patient. In 87 patients, data were extracted at baseline (prosthesis insertion) and 5 years including the width of mid-buccal KM, bleeding on probing, probing depth, plaque index and marginal bone level (MB). Spearman correlations with Holm adjustment for multiple testing were used for potential associations. Results Depending on the definition of peri-implant diseases, the prevalence of peri-implantitis ranged from 9.2% (bleeding on probing threshold: <50% or >= 50%) to 24.1% (threshold: absence or the presence). The prevalence of peri-implant mucositis was similar, irrespective of the definition (54%-55.2%). The width of KM and parameters for peri-implant diseases demonstrated negligible (Spearman correlation coefficients: -0.2 rho < 0.2). No threshold value was detected for the width of mid-buccal KM in relation to peri-implant health. Conclusion The width of KM around dental implants correlated to a negligible extent with parameters for peri-implant diseases. No threshold value for the width of KM to maintain peri-implant health could be identified.
引用
收藏
页码:354 / 362
页数:9
相关论文
共 50 条
  • [41] Volumetric changes and peri-implant health at implant sites with or without soft tissue grafting in the esthetic zone, a retrospective case-control study with a 5-year follow-up
    Bienz, Stefan P.
    Jung, Ronald E.
    Sapata, Vitor M.
    Hammerle, Christoph H. F.
    Husler, Jurg
    Thoma, Daniel S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) : 1459 - 1465
  • [42] Implant health and factors affecting peri-implant marginal bone alteration for implants placed in staged maxillary sinus augmentation: A 5-year prospective study
    Krennmair, Stefan
    Hunger, Stefan
    Forstner, Thomas
    Malek, Michael
    Krennmair, Gerald
    Stimmelmayr, Michael
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (01) : 32 - 41
  • [43] Influence of vertical mucosal thickness and keratinized mucosal width on peri-implant health and marginal bone loss: a prospective study with a 2-year follow-up
    Babayigit, Osman
    Ucan-Yarkac, Fatma
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2024, 29 (03): : e318 - e325
  • [44] Supportive peri-implant therapy following anti-infective surgical peri-implantitis treatment: 5-year survival and success
    Heitz-Mayfield, Lisa J. A.
    Salvi, Giovanni E.
    Mombelli, Andrea
    Loup, Pierre-Jean
    Heitz, Fritz
    Kruger, Estie
    Lang, Niklaus P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (01) : 1 - 6
  • [45] Peri-implant bone loss clinical and radiographic evaluation around rough neck and microthread implants: a 5-year study
    Luis Calvo-Guirado, Jose
    Lopez-Lopez, Patricia J.
    Perez-Albacete Martinez, Carlos
    Javed, Fawad
    Manuel Granero-Marin, Jose
    Mate Sanchez de Val, Jose Eduardo
    Ramirez Fernandez, Maria Piedad
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (06) : 635 - 643
  • [46] Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results
    Park, Han
    Moon, Ik-Sang
    Chung, Chooryung
    Shin, Su-Jung
    Huh, Jong-Ki
    Yun, Jeong-Ho
    Lee, Dong-Won
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2021, 51 (06) : 422 - 432
  • [47] Effect of two designs of implant-supported overdentures on peri-implant and posterior mandibular bone resorptions: a 5-year prospective radiographic study
    Elsyad, Moustafa A.
    Alokda, Mohammed Mahmoud
    Gebreel, Ashraf Anwer
    Hammouda, Nelly Ibrahim
    Habib, Ahmed Ali
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (10) : E184 - E192
  • [48] Occlusal change in posterior implant-supported single crowns and its association with peri-implant bone level: a 5-year prospective study
    Qian Ding
    Qiang Luo
    Yajing Tian
    Lei Zhang
    Qiufei Xie
    Yongsheng Zhou
    Clinical Oral Investigations, 2022, 26 : 4217 - 4227
  • [49] Peri-Implant Marginal Bone Changes around Dental Implants with Platform-Switched and Platform-Matched Abutments: A Retrospective 5-Year Radiographic Evaluation
    Lin, Hsi-Kuei
    Lin, Jerry Chin-Yi
    Pan, Yu-Hwa
    Salamanca, Eisner
    Chang, Yi-Ting
    Hsu, Yung-Szu
    Wu, Yi-Fan
    Lin, Chin-Kai
    Dorj, Odontuya
    Chang, Wei-Jen
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (08):
  • [50] Long-Term Effect of Keratinized Tissue Width on Peri-implant Health Status Indices: An Updated Systematic Review and Meta-analysis
    Heydari, Morteza
    Ataei, Atefe
    Riahi, Seyed Mohammad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (06) : E181 - +