The amount of keratinized mucosa may not influence peri-implant health in compliant patients: A retrospective 5-year analysis

被引:47
|
作者
Lim, Hyun-Chang [1 ,2 ]
Wiedemeier, Daniel B. [3 ]
Hammerle, Christoph H. F. [1 ]
Thoma, Daniel S. [1 ]
机构
[1] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
[2] Kyung Hee Univ, Sch Dent, Periodontal Implant Clin Res Inst, Dept Periodontol, Seoul, South Korea
[3] Univ Zurich, Ctr Dent Med, Stat Serv, Zurich, Switzerland
关键词
dental implant; keratinized mucosa; peri-implant diseases; XENOGENEIC COLLAGEN MATRIX; SOFT-TISSUE AUGMENTATION; DENTAL IMPLANTS; ATTACHED GINGIVA; RISK INDICATORS; FOLLOW-UP; WIDTH; PROSTHESES; DISEASE; ASSOCIATION;
D O I
10.1111/jcpe.13078
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim (a) To investigate the influence of the keratinized mucosa (KM) on peri-implant health or disease and (b) to identify a threshold value for the width of KM for peri-implant health. Materials and Methods The total dataset was subsampled, that is one implant was randomly chosen per patient. In 87 patients, data were extracted at baseline (prosthesis insertion) and 5 years including the width of mid-buccal KM, bleeding on probing, probing depth, plaque index and marginal bone level (MB). Spearman correlations with Holm adjustment for multiple testing were used for potential associations. Results Depending on the definition of peri-implant diseases, the prevalence of peri-implantitis ranged from 9.2% (bleeding on probing threshold: <50% or >= 50%) to 24.1% (threshold: absence or the presence). The prevalence of peri-implant mucositis was similar, irrespective of the definition (54%-55.2%). The width of KM and parameters for peri-implant diseases demonstrated negligible (Spearman correlation coefficients: -0.2 rho < 0.2). No threshold value was detected for the width of mid-buccal KM in relation to peri-implant health. Conclusion The width of KM around dental implants correlated to a negligible extent with parameters for peri-implant diseases. No threshold value for the width of KM to maintain peri-implant health could be identified.
引用
收藏
页码:354 / 362
页数:9
相关论文
共 50 条
  • [21] Long-term evaluation of peri-implant keratinized mucosa stability after free epithelialized graft and keratinized mucosa shifting procedures: A retrospective study up to 13 years
    Chen, Ya-Chi
    Lai, Yu-Lin
    Yen, Jui-Ying
    Lin, Yi-Chun
    Chen, Hsuan-Hung
    Lee, Shyh-Yuan
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1083 - 1093
  • [22] Comparison of clinical and radiographic peri-implant parameters among obese and non-obese patients: A 5-year study
    Alkhudhairy, Fahad
    Vohra, Fahim
    Al-Kheraif, Abdulaziz A.
    Akram, Zohaib
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 756 - 762
  • [23] Retrospective analysis of keratinized tissue augmentation using a xenogeneic collagen matrix for resolving peri-implant mucositis and peri-implantitis
    Park, Jung Soo
    Herr, Yeek
    Chung, Jong-Hyuk
    Shin, Seung-Il
    Lim, Hyun-Chang
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2023, 53 (02) : 145 - 156
  • [24] Xenogeneic Collagen Matrix Versus Free Gingival Graft for Augmenting Peri-Implant Keratinized Mucosa Around Dental Implants: A Systematic Review and Meta-Analysis
    Atieh, Momen A.
    Shah, Maanas
    Hakam, Abeer
    Alshaali, Suhailah
    Kasouha, Reem
    Tawse-Smith, Andrew
    Alsabeeha, Nabeel H. M.
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (04):
  • [25] The effect of brushing discomfort on peri-implant health in sites exhibiting inadequate keratinized mucosa width: A cross-sectional study
    Perussolo, Jeniffer
    Matarazzo, Flavia
    Dias, Debora R.
    Oliveira, Ricardo P.
    Araujo, Mauricio G.
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (12) : 1212 - 1223
  • [26] Influence of the Crown-Implant Connection on the Preservation of Peri-Implant Bone: A Retrospective Multifactorial Analysis
    Galindo-Moreno, Pablo
    Fernandez-Jimenez, Andres
    O'Valle, Francisco
    Monje, Alberto
    Silvestre, Francisco J.
    Juodzbalys, Gintaras
    Sanchez-Fernandez, Elena
    Catena, Andres
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (02) : 384 - 390
  • [27] Impact of keratinized mucosa on implant-health related parameters: A 10-year prospective re-analysis study
    Mancini, Leonardo
    Strauss, Franz J.
    Lim, Hyun-Chang
    Tavelli, Lorenzo
    Jung, Ronald E.
    Naenni, Nadja
    Thoma, Daniel S.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (03) : 554 - 563
  • [28] Incidence of Peri-implant Diseases on Implants With and Without Laser-Microgrooved Collar: A 5-Year Retrospective Study Carried Out in Private Practice Patients
    Guarnieri, Renzo
    Grande, Maurizio
    Zuffetti, Francesco
    Testori, Tiziano
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 457 - 465
  • [29] MicroRNAs in Peri-implant Crevicular Fluid Can Predict Peri-implant Bone Resorption: Clinical Trial with a 5-Year Follow-up
    Menini, Maria
    Pesce, Paolo
    Pera, Francesco
    Baldi, Domenico
    Pulliero, Alessandra
    Izzotti, Alberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (06) : 1148 - 1157
  • [30] Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Leles, Claudio Rodrigues
    de Resende, Gabriela Pereira
    Martins, Nilva de Oliveira
    Nascimento, Lays Noleto
    Costa, Nadia Lago
    Srinivasan, Murali
    Schimmel, Martin