Validation of Pattern-Recognition Monitors in Children Using Doubly Labeled Water

被引:46
|
作者
Calabro, Miguel Andres [1 ]
Stewart, Jeanne M. [2 ]
Welk, Gregory J. [1 ,2 ]
机构
[1] Iowa State Univ, Dept Kinesiol, Ames, IA USA
[2] Iowa State Univ, Nutr & Wellness Res Ctr, Ames, IA USA
来源
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE | 2013年 / 45卷 / 07期
关键词
ENERGY EXPENDITURE; PHYSICAL ACTIVITY; ACTIVITY MONITOR; FREE-LIVING CONDITIONS; DAILY ENERGY-EXPENDITURE; MULTISENSOR ACTIVITY MONITORS; REGRESSION SPLINES MODELS; PHYSICAL-ACTIVITY; ADOLESCENTS; ARMBAND; ACCELEROMETER; PREDICTION; AGREEMENT; ADULTS;
D O I
10.1249/MSS.0b013e31828579c3
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: Accurate assessments of physical activity and energy expenditure (EE) are needed to advance research on childhood obesity prevention. The objective of this study is to evaluate the validity of two SenseWear Armband monitors (the Pro3 (SWA) and the recently released Mini) (BodyMedia Inc., Pittsburgh, PA) under free-living conditions in a youth population. Methods: Twenty-eight healthy children age 10-16 yr wore both monitors for 14 consecutive days, including sleeping time. Estimates of total EE from the monitors were computed using two different algorithms (version 2.2, available in the SenseWear software 6.1 and 7.0, and the newly developed 5.0 algorithms). The EE estimates were compared with estimates derived from doubly labeled water (DLW) methodology using a three-way mixed model ANOVA (sex x monitor x algorithm), correlation analyses, and Bland-Altman plots. Results: The mixed-model ANOVA revealed nonsignificant gender and monitor main effects but a significant main effect for algorithm (P < 0.001). The mean absolute percentage error values were considerably lower with the 5.0 (SWA: 10.9%; Mini: 11.7%) than for the 2.2 algorithm (SWA: 20.7%; Mini: 18.3%). Correlations were high for all comparisons (> 0.90), but the Bland-Altman plots revealed consistent bias (greater overestimation at higher EE values). The variance in the differences between methods that was attributable to the mean level of EE ranged from R-2 = 0.17 to R-2 = 0.44. The magnitude of random error (estimated as the SD of the residuals) ranged from 227 to 299 kcal, but values tended to be lower with the 2.2 algorithm and with the Mini monitor. Conclusions: The newly developed SenseWear Armband 5.0 algorithms outperformed the version 2.2 algorithms for group comparisons, but additional work is needed to understand factors contributing to large individual variability.
引用
收藏
页码:1313 / 1322
页数:10
相关论文
共 50 条
  • [41] Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants
    Johansson, Ulrica
    Venables, Michelle
    Ohlund, Inger
    Lind, Torbjoern
    NUTRIENTS, 2018, 10 (12):
  • [42] Energy Expenditure in Free-Living Japanese People with Obesity and Type 2 Diabetes, Measured Using the Doubly-Labeled Water Method
    Ishikawa-Takata, Kazuko
    Tanaka, Shigeho
    Park, Jonghoon
    Miyachi, Motohiko
    Morita, Akemi
    Aiba, Naomi
    Watanabe, Shaw
    JOURNAL OF NUTRITIONAL SCIENCE AND VITAMINOLOGY, 2020, 66 (04) : 319 - 324
  • [43] Validation of the doubly labeled water method using off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry
    Melanson, Edward L.
    Swibas, Tracy
    Kohrt, Wendy M.
    Catenacci, Vicki A.
    Creasy, Seth A.
    Plasqui, Guy
    Wouters, Loek
    Speakman, John R.
    Berman, Elena S. F.
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2018, 314 (02): : E124 - E130
  • [44] Total energy expenditure measured using doubly labeled water in adults with major chronic diseases: a systematic review
    Purcell, Sarah A.
    Craven, Sarah A.
    Limon-Miro, Ana Teresa
    Elliott, Sarah A.
    Melanson, Edward L.
    Tandon, Puneeta
    Prado, Carla M.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2024, 120 (05): : 1071 - 1084
  • [45] Total energy expenditure measured by doubly labeled water method in children and adolescents: a systematic review
    Kim, Nahyun
    Park, Jonghoon
    CLINICAL AND EXPERIMENTAL PEDIATRICS, 2023, 66 (02) : 54 - 65
  • [46] Energy intake and expenditure: Validation of a diet history by heart rate monitoring, activity diary and doubly labeled water
    E Rothenberg
    I Bosaeus
    B Lernfelt
    S Landahl
    B Steen
    European Journal of Clinical Nutrition, 1998, 52 : 832 - 838
  • [47] Energy intake and expenditure: Validation of a diet history by heart rate monitoring, activity diary and doubly labeled water
    Rothenberg, E
    Bosaeus, I
    Lernfelt, B
    Landahl, S
    Steen, B
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1998, 52 (11) : 832 - 838
  • [48] Comparison of energy requirement estimation using activity record or accelerometer with doubly labeled water method in collegiate male sprinters
    Shimamura, Yuki
    Takemura, Ryusei
    Iwanami, Kensuke
    Yamamoto, Daisuke
    Sagayama, Hiroyuki
    Iwayama, Kaito
    CLINICAL NUTRITION ESPEN, 2024, 61 : 295 - 301
  • [49] Comparative study of total energy expenditure in Japanese men using doubly labeled water method against activity record, heart rate monitoring, and accelerometer methods
    Ebine, N
    Shimada, M
    Tanaka, H
    Nishimuta, M
    Yoshitake, Y
    Saitoh, S
    Jones, PJH
    JAPANESE JOURNAL OF PHYSICAL FITNESS AND SPORTS MEDICINE, 2002, 51 (01) : 151 - 163
  • [50] Energy Requirement Assessment in Japanese Table Tennis Players Using the Doubly Labeled Water Method
    Sagayama, Hiroyuki
    Hamaguchi, Genki
    Toguchi, Makiko
    Ichikawa, Mamiko
    Yamada, Yosuke
    Ebine, Naoyuki
    Higaki, Yasuki
    Tanaka, Hiroaki
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2017, 27 (05) : 421 - 428