CFD and exergy analysis of subcritical/supercritical CO2 based naturally circulated solar thermal collector

被引:5
作者
Biradar, Madagonda K. [1 ]
Parmar, Dipal N. [1 ]
Yadav, Ajay Kumar [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Mangalore 575025, India
关键词
Solar thermal collector; Natural circulation loop; CFD; Supercritical carbon dioxide; Heat transfer; Exergy; SUPERCRITICAL CO2; HEATING-SYSTEMS; BALANCE;
D O I
10.1016/j.renene.2022.03.056
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar water heating system is inefficient during winter due to the chances of water freezing and higher viscosity at low temperatures. Several investigations are being done to increase the efficiency of the solar water heater using various secondary fluids for different climatic conditions. This paper emphasises on the study of heat transfer and fluid flow behavior of CO2 based naturally circulated indirect solar water heating system. Subcritical (liquid and vapour) and supercritical CO2 are considered as loop fluid, and the results are compared with water based system. Three-dimensional computational fluid dynamics simulations are carried out for two different weather conditions i.e., winter (278 K) and summer (305 K). Results are obtained for 33 & DEG; collector inclination angle from horizontal at various operating pressures 50-70 bar for subcritical and 80-100 bar for supercritical CO2. The CO2 based system yields very high Reynolds number (subcritical liquid:-160 times; subcritical vapour:-204 times; supercritical vapour: -260 times) and very high Nusselt number (subcritical liquid:-14 times; subcritical vapour:-19.5 times; supercritical vapour: -48 times) compared to water based system. Supercritical CO2 based system exhibits 12% higher energy efficiency compared to water. Whereas, subcritical vapour based system exhibits 140% higher exergy efficiency relative to water based system. (C) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:865 / 880
页数:16
相关论文
共 26 条
[1]   Parametric Quantification of Low GWP Refrigerant for Thermosyphon Driven Solar Water Heating System [J].
Abas, Naeem ;
Nawaz, Rab ;
Khan, Nasrullah .
6TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT-2015), THE 5TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2015), 2015, 52 :804-811
[2]   CALCULATION OF THE TOP LOSS COEFFICIENT OF A FLAT-PLATE COLLECTOR [J].
AGARWAL, VK ;
LARSON, DC .
SOLAR ENERGY, 1981, 27 (01) :69-71
[3]   Numerical modeling of supercritical CO2 natural circulation loop [J].
Archana, V. ;
Vaidya, A. M. ;
Vijayan, P. K. .
NUCLEAR ENGINEERING AND DESIGN, 2015, 293 :330-345
[4]  
Bejan A., 1988, ADV ENG THERMODYNAMI
[5]  
Boyle G., 2004, RENEWABLE ENERGY POW, V2nd
[6]   Exergetic optimization of flat plate solar collectors [J].
Farahat, S. ;
Sarhaddi, F. ;
Ajam, H. .
RENEWABLE ENERGY, 2009, 34 (04) :1169-1174
[7]  
Gupta K.K. Dutta, 1990, Renew. Energy Environ, V33, P283
[8]  
Hottel H.C., 1954, Radiant heat transmission, V3rd
[9]   Feasibility study of the application of solar heating systems in Iran [J].
Keyanpour-Rad, M ;
Haghgou, HR ;
Bahar, F ;
Afshari, E .
RENEWABLE ENERGY, 2000, 20 (03) :333-345
[10]   CALCULATION OF FLAT-PLATE COLLECTOR LOSS COEFFICIENTS [J].
KLEIN, SA .
SOLAR ENERGY, 1975, 17 (01) :79-80