Investigation of the potential induced degradation of on-site aged polycrystalline PV modules operating in Malaysia

被引:25
作者
Islam, M. A. [1 ,2 ]
Hasanuzzaman, M. [1 ]
Abd Rahim, Nasrudin [1 ,3 ]
机构
[1] Univ Malaya, UM Power Energy Dedicated Adv Ctr, Wisma R&D, Level 4, Kuala Lumpur 59990, Malaysia
[2] Univ Malaya, Inst Grad Studies, Kuala Lumpur 50603, Malaysia
[3] King Abdulaziz Univ, Renewable Energy Res Grp, Jeddah, Saudi Arabia
关键词
On-site PID; EL imaging; Aging effect; Shunt resistance; Leakage current; PHOTOVOLTAIC MODULES; POWER;
D O I
10.1016/j.measurement.2018.01.061
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
On-site investigation of PID behavior of PV module has been carried out under typical Malaysian climate. A quantitative degradation measurement process of PV module through EL imaging has been introduced. PID has been observed only for the negative voltage stress in this p-type polycrystalline Si PV module. The negative end PV module degrades 42% due to 9 years field aging under a negative voltage stress from the 240 V string size. While positive end PV module is degraded near about 17% over the same period due to normal field aging. Shunt resistance of negative-end module has been found 75% lower than that of the positive-end module. Module crack propagation is found to be accelerated due to onsite cyclic high voltage stress. PID at higher string size has been estimated from the leakage current of brand new same PV module. The estimated PID of PV module under 600 V stress is 72.84%.
引用
收藏
页码:283 / 294
页数:12
相关论文
共 41 条
  • [41] Long-term experiment on p-type crystalline PV module with potential induced degradation: Impact on power performance and evaluation of recovery mode
    Bouaichi, Abdellatif
    Merrouni, Ahmed Alami
    El Amrani, Aumeur
    Jaeckel, Bengt
    Hajjaj, Charaf
    Naimi, Zakaria
    Messaoudi, Choukri