Hemolysis test of disposable type vibrating flow pump

被引:3
|
作者
Kobayashi, S [1 ]
Nitta, S [1 ]
Yambe, T [1 ]
Sonobe, T [1 ]
Naganuma, S [1 ]
Hashimoto, H [1 ]
机构
[1] TOHOKU UNIV,INST FLUID SCI,SENDAI,MIYAGI 980,JAPAN
关键词
vibrating flow pump; oscillated blood flow; hemolysis test; electromagnetic actuator;
D O I
10.1111/j.1525-1594.1997.tb03724.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The vibrating flow pump (VFP) can generate high frequency oscillated blood flow. Because of the high frequency driving with short stroke volume, the pump system can be small. The disposable type VFP (D-VFP) was developed for use for extracorporeal circulation. The electromagnetic actuator was detached from the vibrating tube, which was newly designed to be a disposable tube with a jellyfish valve. Hemolysis tests of the D-VFP, VFP, centrifugal pump, and roller pump were performed in a mock circulation study using goat blood. Plasma free hemoglobin was measured every 15 min under the same conditions. The plasma free hemoglobin of the D-VFP was 16 mg/dl although that of the VFP was 160 mg/dl at 30 min. The plasma free hemoglobin of the centrifugal pump and roller pump at 30 min were 3 mg/dl and 9 mg/dl, respectively. The hemolysis performance of the D-VFP may be studied further as a result of this study. Two important factors affecting hemolysis development may be the materials of which the vibrating tube is made and heat transmission from the actuator. The D-VFP has a smooth acrylic surface for blood contact compared with the metal surface of old type VFP. The electromagnetic actuator of the VFP surrounded the vibrating tube, so heat from the actuator could be easily transmitted to the blood. Because the D-VFP has a disposable vibrating tube that is detached from the actuator, heat is not readily transmitted to the blood. A mock circulation study of heat transmission was performed using the D-VFP and VFP. Results of the heat transmission study showed that the fluid temperature of the D-VFP was not increased and stayed at room temperature although that of the VFP increased approximately 1 degrees C above room temperature. The D-VFP may be a good style for the development of the VFP for use for extracorporeal circulation.
引用
收藏
页码:691 / 693
页数:3
相关论文
共 50 条
  • [1] Computational flow visualization in vibrating flow pump type artificial heart by unstructured grid
    Kato, T
    Kawano, S
    Nakahashi, K
    Yambe, T
    Nitta, S
    Hashimoto, H
    ARTIFICIAL ORGANS, 2003, 27 (01) : 41 - 48
  • [2] Relationship between pump speed design and hemolysis in an axial flow blood pump
    Texas Heart Institute, Houston, TX, United States
    不详
    不详
    不详
    ARTIF. ORGANS, 5 (564-567):
  • [3] Relationship between pump speed design and hemolysis in an axial flow blood pump
    Anai, H
    Wakisaka, Y
    Nakatani, T
    Taenaka, Y
    Takano, H
    Hadama, T
    ARTIFICIAL ORGANS, 1996, 20 (06) : 564 - 567
  • [4] The hemolysis test of pulsatile blood pump, T-PLS™
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 947 - 947
  • [5] Comparison of centrifugal and roller pump hemolysis rates at low flow
    Moon, YS
    Ohtsubo, S
    Gomez, MR
    Moon, JK
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (06) : 579 - 581
  • [6] Assessment of Hemolysis in a Ventricular Assist Axial Flow Blood Pump
    Gouskov A.M.
    Lomakin V.O.
    Banin E.P.
    Kuleshova M.S.
    Biomedical Engineering, 2016, 50 (4) : 233 - 236
  • [7] FLOW VISUALIZATION AROUND ACTUATING VALVE OF MICRO-VIBRATING FLOW PUMP
    Osman, Osman Omran
    Shintaku, Hirofumi
    Kawano, Satoyuki
    FLUID MEASUREMENTS AND INSTRUMENTATION CAVITATION AND MULTIPHASE FLOW ADVANCES IN FLUIDS ENGINEERING EDUCATION MICROFLUIDICS, VOL 2, 2012, : 339 - 341
  • [8] Chaotic dynamics in circulation with Tohoku University vibrating flow pump
    Nitta, S
    Yambe, T
    Kobayashi, SI
    Hashimoto, H
    Yoshizawa, M
    Mastuki, H
    Tabayashi, K
    Takeda, H
    ARTIFICIAL ORGANS, 1999, 23 (01) : 119 - 123
  • [9] FRACTAL DIMENSION ANALYSIS OF THE OSCILLATED BLOOD-FLOW WITH A VIBRATING FLOW PUMP
    YAMBE, T
    SONOBE, T
    NAGANUMA, S
    KOBAYASHI, S
    NANKA, S
    AKIHO, H
    KAKINUMA, Y
    MITSUOKA, M
    CHIBA, S
    OHSAWA, N
    HAGA, Y
    IDUTSU, K
    NITTA, S
    FUKUJU, T
    MIURA, M
    UCHIDA, N
    SATO, N
    TABAYASHI, K
    TANAKA, A
    YOSHIZUMI, N
    ABE, K
    TAKAYASU, M
    TAKAYASU, H
    YOSHIZAWA, M
    MAEKAWA, T
    HASHIMOTO, H
    ARTIFICIAL ORGANS, 1995, 19 (07) : 729 - 733
  • [10] Development of vibrating flow pump for left ventricular assist circulation
    Kobayashi, S
    Nitta, S
    Yambe, T
    Sonobe, T
    Nannka, S
    Shizuka, K
    Fkuju, T
    Hashimoto, H
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (04): : 225 - 228