Calibration of the CMS hadron calorimeter in Run 2

被引:1
|
作者
Chadeeva, M. [1 ,2 ]
Lychkovskaya, N. [3 ]
机构
[1] NRNU MEPhI, 31 Kashirskoe Shosse, Moscow, Russia
[2] PN Lebedev Phys Inst, 53 Leninsky Prospect, Moscow, Russia
[3] ITEP, 25 B Cheremushkinskaya, Moscow, Russia
来源
JOURNAL OF INSTRUMENTATION | 2018年 / 13卷
关键词
Calorimeters; Detector alignment and calibration methods (lasers; sources; particle-beams); Performance of High Energy Physics Detectors;
D O I
10.1088/1748-0221/13/03/C03025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Various calibration techniques for the CMS Hadron calorimeter in Run 2 and the results of calibration using 2016 collision data are presented. The radiation damage corrections, inter-calibration of different channels using the phi-symmetry technique for barrel, endcap and forward calorimeter regions are described, as well as the intercalibration with muons of the outer hadron calorimeter. The achieved intercalibration precision is within 3%. The in situ energy scale calibration is performed in the barrel and endcap regions using isolated charged hadrons and in the forward calorimeter using the Z -> ee process. The impact of pileup and the developed technique of correction for pileup is also discussed. The achieved uncertainty of the response to hadrons is 3.4% in the barrel and 2.6% in the endcap region (at the pseudorapidity range vertical bar eta vertical bar < 2) and is dominated by the systematic uncertainty due to pileup contributions.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Calibration of the CMS hadron calorimeters using proton-proton collision data at √s=13 TeV
    Sirunyan, A. M.
    Tumasyan, A.
    Adam, W.
    Ambrogi, F.
    Bergauer, T.
    Brandstetter, J.
    Dragicevic, M.
    Eroe, J.
    Del Valle, A. Escalante
    Flechl, M.
    Fruehwirth, R.
    Jeitler, M.
    Krammer, N.
    Kraetschmer, I
    Liko, D.
    Madlener, T.
    Mikulec, I
    Rad, N.
    Schieck, J.
    Schoefbeck, R.
    Spanring, M.
    Spitzbart, D.
    Waltenberger, W.
    Wulz, C-E
    Zarucki, M.
    Chekhovsky, V
    Mossolov, V
    Gonzalez, J. Suarez
    Darwish, M. R.
    De Wolf, E. A.
    Di Croce, D.
    Janssen, X.
    Lelek, A.
    Pieters, M.
    Sfar, H. Rejeb
    Van Haevermaet, H.
    Van Mechelen, P.
    Van Putte, S.
    Van Remortel, N.
    Blekman, F.
    Bols, E. S.
    Chhibra, S. S.
    D'Hondt, J.
    De Clercq, J.
    Lontkovskyi, D.
    Lowette, S.
    Marchesini, I
    Moortgat, S.
    Moreels, L.
    Python, Q.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (05)
  • [22] Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s=7 TeV
    Chatrchyan, S.
    Khachatryan, V.
    Sirunyan, A. M.
    Tumasyan, A.
    Adam, W.
    Bergauer, T.
    Dragicevic, M.
    Eroe, J.
    Fabjan, C.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Hoermann, N.
    Hrubec, J.
    Jeitler, M.
    Kiesenhofer, W.
    Knuenz, V.
    Krammer, M.
    Kraetschmer, I.
    Liko, D.
    Mikulec, I.
    Rabady, D.
    Rahbaran, B.
    Rohringer, C.
    Rohringer, H.
    Schoefbeck, R.
    Strauss, J.
    Taurok, A.
    Treberer-Treberspurg, W.
    Waltenberger, W.
    Wulz, C. -E.
    Mossolov, V.
    Shumeiko, N.
    Suarez Gonzalez, J.
    Alderweireldt, S.
    Bansal, M.
    Bansal, S.
    Cornelis, T.
    De Wolf, E. A.
    Janssen, X.
    Knutsson, A.
    Luyckx, S.
    Mucibello, L.
    Ochesanu, S.
    Roland, B.
    Rougny, R.
    Van Haevermaet, H.
    Van Mechelen, P.
    Van Remortel, N.
    Van Spilbeeck, A.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [23] Operational experience with the CMS pixel detector in LHC Run II
    Karancsi, J.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [24] High voltage calibration method for the CMS RPC detector
    Reyes-Almanza, R.
    Dimitrov, A.
    Fagot, A.
    Gul, M.
    Roskas, C.
    Tytgat, M.
    Zaganidis, N.
    Fonseca De Souza, S.
    Santoro, A.
    Da Silva De Araujo, F. Torres
    Aleksandrov, A.
    Hadjiiska, R.
    Iaydjiev, P.
    Rodozov, M.
    Shopova, M.
    Sultanov, G.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Petrov, A.
    Qian, S. J.
    Han, D.
    Yi, W.
    Avila, C.
    Cabrera, A.
    Carrillo, C.
    Segura, M.
    Aly, S.
    Assran, Y.
    Mahrous, A.
    Mohamed, A.
    Combaret, C.
    Gouzevitch, M.
    Grenier, G.
    Lagarde, F.
    Laktineh, I. B.
    Mathez, H.
    Mirabito, L.
    Shchablo, K.
    Bagaturia, I.
    Lomidze, D.
    Lomidze, I.
    Pant, L. M.
    Bhatnagar, V.
    Gupta, R.
    Kumari, R.
    Lohan, M.
    Singh, J. B.
    Amoozegar, V.
    Boghrati, B.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (09):
  • [25] Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data
    Chatrchyan, S.
    Khachatryan, V.
    Sirunyan, A. M.
    Adam, W.
    Arnold, B.
    Bergauer, H.
    Bergauer, T.
    Dragicevic, M.
    Eichberger, M.
    Eroe, J.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Hammer, J.
    Haensel, S.
    Hoch, M.
    Hoermann, N.
    Hrubec, J.
    Jeitler, M.
    Kasieczka, G.
    Kastner, K.
    Krammer, M.
    Liko, D.
    de Abril, I. Magrans
    Mikulec, I.
    Mittermayr, F.
    Neuherz, B.
    Oberegger, M.
    Padrta, M.
    Pernicka, M.
    Rohringer, H.
    Schmid, S.
    Schoefbeck, R.
    Schreiner, T.
    Stark, R.
    Steininger, H.
    Strauss, J.
    Taurok, A.
    Teischinger, F.
    Themel, T.
    Uhl, D.
    Wagner, P.
    Waltenberger, W.
    Walzel, G.
    Widl, E.
    Wulz, C-E
    Chekhovsky, V.
    Dvornikov, O.
    Emeliantchik, I.
    Litomin, A.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [26] Test beam measurements of the CMS High Granularity Calorimeter
    Choudhury, S.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (01):
  • [27] The CMS High Granularity Calorimeter for the High Luminosity LHC
    Sauvan, J. -B.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [28] ATLAS LAr calorimeter performance in LHC Run 2
    Mahon, D. J.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06):
  • [29] ATLAS LAr Calorimeter performance in LHC Run 2
    Spalla, M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (04)
  • [30] Energy calibration of the barrel calorimeter of the CMD-3 detector
    Anisenkov, A. V.
    Aulchenko, V. M.
    Bashtovoy, N. S.
    Bondar, A. E.
    Grebenuk, A. A.
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmin, A. S.
    Mikhailov, K. Yu.
    Logashenko, I. B.
    Razuvaev, G. P.
    Ruban, A. A.
    Shebalin, V. E.
    Shwartz, B. A.
    Talyshev, A. A.
    Titov, V. M.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2017, 12