Measurements of the photon detection inefficiency of calorimeters between 185 and 505 MeV

被引:7
作者
Ajimura, S
Endo, T
Inagaki, T
Itoh, S
Kuno, Y
Maeda, K
Maruyama, K
Nakano, T
Okuno, H
Sato, T
Shinkawa, T
Suda, T
Sugiyama, K
Terasawa, T
Toyofuku, A
机构
[1] High Energy Accelerator Res Org KEK, Tsukuba, Ibaraki 305, Japan
[2] Osaka Univ, Dept Phys, Toyonaka, Osaka 560, Japan
[3] Tohoku Univ, Dept Phys, Sendai, Miyagi 980, Japan
[4] Inst Phys & Chem Res, Wako, Saitama 35101, Japan
[5] Univ Tokyo, Ctr Nucl Study, Tanashi, Tokyo 188, Japan
[6] KEK, Tanashi Branch, Tanashi, Tokyo 188, Japan
[7] Tohoku Univ, Nucl Sci Lab, Sendai, Miyagi 982, Japan
关键词
calorimeter inefficiency; tagged photon beam; first-nucleon-resonance region;
D O I
10.1016/S0168-9002(99)00571-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The detection inefficiencies for photons of total-absorption-type electromagnetic calorimeters, an undoped CsI crystal counter and a lead-scintillator sandwich counter, have been measured at photon energies (E gamma) between 185 and 505 MeV with the ragged photon beam from the INS-ES. The effect of punch-through is estimated by an EGS calculation. The other source of inefficiency, the photonuclear interaction effect, is examined after the interaction is identified by neutron signals observed with liquid scintillation counters surrounding the sample calorimeter. The inefficiency due to the photonuclear interaction in the case of the CsI calorimeter at 1-MeV threshold is found to be 10(-5)-10(-6) and shows a monotonic decrease with E gamma. The detection inefficiency of the sandwich calorimeter is found to be dominated by the sampling effect after photonuclear interactions. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:408 / 422
页数:15
相关论文
共 8 条
  • [1] TOTAL NUCLEAR PHOTON ABSORPTION CROSS-SECTIONS FOR SOME LIGHT ELEMENTS
    AHRENS, J
    BORCHERT, H
    CZOCK, KH
    EPPLER, HB
    GIMM, H
    GUNDRUM, H
    KRONING, M
    RIEHN, P
    RAM, GS
    ZIEGER, A
    ZIEGLER, B
    [J]. NUCLEAR PHYSICS A, 1975, 251 (03) : 479 - 492
  • [2] PHOTON TAGGING SYSTEM AT INS ELECTRON SYNCHROTRON
    ARAI, S
    HOMMA, S
    ITANO, A
    INAGAKI, T
    KASUYA, M
    MARUYAMA, K
    MIYACHI, T
    OKUNO, H
    SASAKI, A
    SATO, I
    UKAI, K
    YAMAKAWA, T
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 1975, 14 (01) : 95 - 100
  • [3] TOTAL PHOTONUCLEAR ABSORPTION CROSS-SECTION FOR PB AND FOR HEAVY-NUCLEI IN THE DELTA-RESONANCE REGION
    CARLOS, P
    BEIL, H
    BERGERE, R
    FAGOT, J
    LEPRETRE, A
    DEMINIAC, A
    VEYSSIERE, A
    [J]. NUCLEAR PHYSICS A, 1984, 431 (04) : 573 - 592
  • [4] DETECTION INEFFICIENCY OF A 10 MM THICK PLASTIC SCINTILLATION-COUNTER FOR 1 GEV/C E(+/-), PI(+/-) AND PROTONS
    INAGAKI, T
    HIRAYAMA, H
    SATO, T
    SHINKAWA, T
    YOSHIMURA, Y
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (03) : 478 - 484
  • [5] INAGAKI T, 1996, 9613 KEK
  • [6] MEASUREMENTS OF THE TOTAL PHOTO-NUCLEAR CROSS-SECTIONS FROM 30MEV TO 140MEV FOR SN, CE, TA, PB AND U NUCLEI
    LEPRETRE, A
    BEIL, H
    BERGERE, R
    CARLOS, P
    FAGOT, J
    DEMINIAC, A
    VEYSSIERE, A
    [J]. NUCLEAR PHYSICS A, 1981, 367 (02) : 237 - 268
  • [7] Mutoh M., 1987, Journal of Science of the Hiroshima University, Series A (Physics and Chemistry), V51, P187
  • [8] Nelson W.R., 1985, EGS4 CODE SYSTEM