Blood screening for human immunodeficiency virus: a new algorithm to reduce the false-positive results

被引:1
|
作者
Zhang, R. [1 ]
Sun, Y. [1 ]
Wang, L. [1 ]
Zhang, K. [1 ]
Xie, J. [1 ]
Li, J. [1 ]
机构
[1] Beijing Hosp, Minist Hlth, Natl Ctr Clin Labs, Beijing 100730, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
anti-HIV; cut-off ratio; enzyme-linked immunosorbent assay; false-positive results; HIV; IMMUNOASSAYS; RATIOS; RNA; HBV; HCV;
D O I
10.1111/tme.12042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesThe objectives to this study were to evaluate the performance of an anti-human immunodeficiency virus (HIV) blood screening test and propose a new screening algorithm for blood banks routinely using nucleic acid amplification testing (NAT) to reduce false-positive results. BackgroundMost anti-HIV enzyme-linked immunosorbent assay (ELISA) results are false-positive because of the low prevalence of HIV infection and high sensitivity of the ELISAs. Methods/MaterialsA total of 281 588 voluntary donations were collected and sera reactive on one or both anti-HIV ELISAs were confirmed by Western blot (WB) testing. All samples with nonreactive results for the two ELISAs underwent NAT. A confirmed HIV-1-positive result was defined by a reactive result on NAT or WB testing. Correlations between signal-to-cutoff ratios and the confirmed HIV-1 infection rate were analysed for each enzyme immunoassay and two-enzyme immunoassay combination. The positive predictive values (PPVs) of the current and proposed algorithms were calculated. ResultsSeventy-nine donations (13<bold>9</bold>%) were positive on WB analysis and one donation negative for anti-HIV antibody was reactive on NAT and confirmed to be a window period donation on additional follow-up testing. The PPV of the 567 donations reactive on one or two ELISAs was 13<bold>9</bold>%. However, using the new screening algorithm, 457 donations underwent NAT immediately instead of WB testing. Only 110 donations were tested with WB and the PPV was 71<bold>8</bold>%. ConclusionScreening for HIV is sensitive, specific and time saving for donors with this algorithm, which is suitable for HIV screening in low prevalence settings.
引用
收藏
页码:260 / 264
页数:5
相关论文
共 50 条
  • [1] A Human Immunodeficiency Virus Screening Algorithm to Address the High Rate of False-Positive Results in Pregnant Women in Japan
    Shima-Sano, Takako
    Yamada, Rika
    Sekita, Kazuyo
    Hankins, Raleigh W.
    Hori, Hiromasa
    Seto, Hiroshi
    Sudo, Koji
    Kondo, Makiko
    Kawahara, Kazuo
    Tsukahara, Yuki
    Inaba, Noriyuki
    Kato, Shingo
    Imai, Mitsunobu
    PLOS ONE, 2010, 5 (02):
  • [2] High rate of hepatitis C virus and human immunodeficiency virus false-positive results in serologic screening in sub-Saharan Africa: adverse impact on the blood supply
    Candotti, Daniel
    Sauvage, Virginie
    Cappy, Pierre
    Boullahi, Mohamed Abdallahi
    Bizimana, Pascal
    Mbensa, Guy Olivier
    Coulibaly, Sekou Oumar
    Alson, Aimee Olivat Rakoto
    Soumana, Hadiza
    Tagny-Tayou, Claude
    Murphy, Edward L.
    Laperche, Syria
    TRANSFUSION, 2020, 60 (01) : 106 - 116
  • [3] A retrospective analysis of false-positive infectious screening results in blood donors
    Vo, Michelle T.
    Bruhn, Roberta
    Kaidarova, Zhanna
    Custer, Brian S.
    Murphy, Edward L.
    Bloch, Evan M.
    TRANSFUSION, 2016, 56 (02) : 457 - 465
  • [4] False-Positive Human Immunodeficiency Virus-1 Test Results With Rapid Seroreversion After Third-Trimester Tdap Booster Vaccination
    Yu, Karl O. A.
    Glassman, Seth R.
    Link, Heather M.
    OBSTETRICS AND GYNECOLOGY, 2024, 144 (06) : e125 - e128
  • [5] False-Positive Results for Human Immunodeficiency Virus Type 1 Nucleic Acid Amplification Testing in Chimeric Antigen Receptor T Cell Therapy
    Hauser, Jocelyn R.
    Hong, Hong
    Babady, N. Esther
    Papanicolaou, Genovefa A.
    Tang, Yi-Wei
    JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (01)
  • [6] The Cumulative Risk of False-Positive Results in the Norwegian Breast Cancer Screening Program: Updated Results
    Roman, Marta
    Hubbard, Rebecca A.
    Sebuodegard, Sofie
    Miglioretti, Diana L.
    Castells, Xavier
    Hofvind, Solveig
    CANCER, 2013, 119 (22) : 3952 - 3958
  • [7] Impact of false-positive newborn metabolic screening results on early health care utilization
    Lipstein, Ellen A.
    Perrin, James M.
    Waisbren, Susan E.
    Prosser, Lisa A.
    GENETICS IN MEDICINE, 2009, 11 (10) : 716 - 721
  • [8] The Psychological Impact of a False-Positive Screening Mammogram in Barcelona
    Espasa, Rebecca
    Murta-Nascimento, Cristiane
    Bayes, Ramon
    Sala, Maria
    Casamitjana, Montserrat
    Macia, Francesc
    Castells, Xavier
    JOURNAL OF CANCER EDUCATION, 2012, 27 (04) : 780 - 785
  • [9] The Psychological Impact of a False-Positive Screening Mammogram in Barcelona
    Rebecca Espasa
    Cristiane Murta-Nascimento
    Ramón Bayés
    Maria Sala
    Montserrat Casamitjana
    Francesc Macià
    Xavier Castells
    Journal of Cancer Education, 2012, 27 : 780 - 785
  • [10] Follow-up program for blood donors with unconfirmed screening results reveals a high false-positive rate in Dalian, China
    Deng, Xuelian
    Zang, Liang
    Wang, Xinmei
    Chen, Hui
    Liu, Jiangdi
    Gao, Yong
    Xu, Shuang
    Wang, Li
    Fan, Yaxin
    Candotti, Daniel
    Liang, Xiaohua
    TRANSFUSION, 2020, 60 (02) : 334 - 342