Conventional pulse transit times as markers of blood pressure changes in humans

被引:64
作者
Block, Robert C. [1 ]
Yavarimanesh, Mohammad [2 ]
Natarajan, Keerthana [2 ]
Carek, Andrew [3 ]
Mousavi, Azin [4 ]
Chandrasekhar, Anand [2 ]
Kim, Chang-Sei [5 ]
Zhu, Junxi [4 ]
Schifitto, Giovanni [6 ,7 ]
Mestha, Lalit K. [8 ]
Inan, Omer T. [3 ]
Hahn, Jin-Oh [4 ]
Mukkamala, Ramakrishna [2 ,9 ]
机构
[1] Univ Rochester, Sch Med & Dent, Dept Publ Hlth Sci, Rochester, NY USA
[2] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[3] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[4] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[5] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[6] Univ Rochester, Sch Med & Dent, Dept Neurol, Rochester, MN USA
[7] Univ Rochester, Sch Med & Dent, Dept Imaging, Rochester, MN USA
[8] Univ Texas Arlington, Dept Elect Engn, Arlington, TX 76019 USA
[9] Univ Pittsburgh, Dept Bioengn & Anesthesiol & Perioperat Med, 302 Benedum Hall,3700 OHara St, Pittsburgh, PA 15261 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1038/s41598-020-73143-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Pulse transit time (PTT) represents a potential approach for cuff-less blood pressure (BP) monitoring. Conventionally, PTT is determined by (1) measuring (a) ECG and ear, finger, or toe PPG waveforms or (b) two of these PPG waveforms and (2) detecting the time delay between the waveforms. The conventional PTTs (cPTTs) were compared in terms of correlation with BP in humans. Thirty-two volunteers [50% female; 52 (17) (mean (SD)) years; 25% hypertensive] were studied. The four waveforms and manual cuff BP were recorded before and after slow breathing, mental arithmetic, cold pressor, and sublingual nitroglycerin. Six cPTTs were detected as the time delays between the ECG R-wave and ear PPG foot, R-wave and finger PPG foot [finger pulse arrival time (PAT)], R-wave and toe PPG foot (toe PAT), ear and finger PPG feet, ear and toe PPG feet, and finger and toe PPG feet. These time delays were also detected via PPG peaks. The best correlation by a substantial extent was between toe PAT via the PPG foot and systolic BP [- 0.63 +/- 0.05 (mean +/- SE); p<0.001 via one-way ANOVA]. Toe PAT is superior to other cPTTs including the popular finger PAT as a marker of changes in BP and systolic BP in particular.
引用
收藏
页数:9
相关论文
共 23 条
[1]   Cardiovascular and neuroendocrine adjustment to public speaking and mental arithmetic stressors [J].
AlAbsi, M ;
Bongard, S ;
Buchanan, T ;
Pincomb, GA ;
Licinio, J ;
Lovallo, WR .
PSYCHOPHYSIOLOGY, 1997, 34 (03) :266-275
[2]   Blood Pressure Estimation Using Pulse Transit Time From Bioimpedance and Continuous Wave Radar [J].
Buxi, Dilpreet ;
Redout, Jean-Michel ;
Yuce, Mehmet Rasit .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (04) :917-927
[3]   PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement [J].
Chandrasekhar, Anand ;
Yavarimanesh, Mohammad ;
Natarajan, Keerthana ;
Hahn, Jin-Oh ;
Mukkamala, Ramakrishna .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (11) :3134-3140
[4]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[5]   Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity [J].
Chen, Yan ;
Wen, Changyun ;
Tao, Guocai ;
Bi, Min ;
Li, Guoqi .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (11) :2222-2233
[6]  
Di Rienzo M, 2015, IEEE ENG MED BIO, P7184, DOI 10.1109/EMBC.2015.7320049
[7]   Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations [J].
Escobar-Restrepo, Braiam ;
Torres-Villa, Robinson ;
Kyriacou, Panayiotis A. .
FRONTIERS IN PHYSIOLOGY, 2018, 9
[8]   Estimation of Pulse Transit Time as a Function of Blood Pressure Using a Nonlinear Arterial Tube-Load Model [J].
Gao, Mingwu ;
Cheng, Hao-Min ;
Sung, Shih-Hsien ;
Chen, Chen-Huan ;
Olivier, Nicholas Bari ;
Mukkamala, Ramakrishna .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (07) :1524-1534
[9]   Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference [J].
Gao, Mingwu ;
Olivier, N. Bari ;
Mukkamala, Ramakrishna .
PHYSIOLOGICAL REPORTS, 2016, 4 (10)
[10]   Estimation of Cardiovascular Risk Predictors from Non-Invasively Measured Diametric Pulse Volume Waveforms via Multiple Measurement Information Fusion [J].
Ghasemi, Zahra ;
Lee, Jong Chan ;
Kim, Chang-Sei ;
Cheng, Hao-Min ;
Sung, Shih-Hsien ;
Chen, Chen-Huan ;
Mukkamala, Ramakrishna ;
Hahn, Jin-Oh .
SCIENTIFIC REPORTS, 2018, 8