Imaging linear accelerator output using a high-speed scintillation based electronic portal imaging device (Hi-EPID)

被引:0
作者
Ranade, Manisha [1 ,2 ]
Lynch, Bart [2 ]
Li, Jonathan [2 ]
Kim, Siyong [2 ]
Dempsey, James [2 ]
机构
[1] Univ Florida, Dept Radiat Oncol, 2000 SW Archer Rd, Gainesville, FL 32610 USA
[2] Univ Florida, Gainesville, FL 32611 USA
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6 | 2007年 / 14卷
关键词
Therapy verification; IMRT dose verification; Linear accelerator output measurement; EPID;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a high-speed scintillation based electronic portal imaging device (Hi-EPID) to image the fluence output of a linear accelerator as it exits the head. The Hi-EPID consists of a high speed digital camera coupled with a fast terbium-doped gadolinium-oxy-sulfide (Gd2O2S:Tb) scintillator. The camera can record every single radiation pulse out of the accelerator, at up to 500 frames per second. Since the Hi-EPID allows us to simultaneously obtain both the fluence and the field shape in a delivery, it serves as an independent means of verifying treatment delivery. In this study, we used the Hi-EPID to analyze the characteristics of the fluence delivered from a commercial clinical linear accelerator (Synergy (R) S, Elekta). Both open field and multileaf collimator (MLC) based intensity modulated radiation therapy (IMRT) fields were evaluated. Fluence delivery irregularities were observed with the Hi-EPID device. Fluence was not constant over the duration of a segment, resulting in a varying dose rate. For the open field delivery, the fluence increased with time until it reached a plateau (in approximately 100 ins), remaining constant over the remainder of the delivery. However, in the case of a six segment IMRT field delivery, the fluence variation differed between segments. For some segments, the fluence increased in the beginning and then reached a plateau. For others, the fluence rose and fell sharply, followed by a slower rise to the plateau. The rapid fluence variation before a plateau was as high as 50% of the maximum. Though the total fluence was correctly delivered, this result is intriguing and calls for further investigation. An analysis of field shapes showed no unplanned motion of MLC during step and shoot delivery, as has been reported for another clinical linear accelerator.
引用
收藏
页码:1811 / +
页数:2
相关论文
共 50 条
  • [41] The experience of a developing country using an electronic portal imaging device for the verification of patient positioning and dosimetry in radiotherapy for prostate cancer
    Farhat, Leila
    Fourati, N.
    Mnejja, W.
    Daoud, J.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (03) : 297 - 301
  • [42] Dose response characteristics of a novel CCD camera-based electronic portal imaging device comparison with OCTAVIUS detector
    Anvari, Akbar
    Aghamiri, Seyed Mahmoud Reza
    Mahdavi, Seyed Rabie
    Alaei, Parham
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (04) : 765 - 769
  • [43] Using multileaf collimator interleaf leakage to extract absolute spatial information from electronic portal imaging device images
    Gao, Zhanrong
    Szanto, Janos
    Gerig, Lee
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (01): : 1 - 9
  • [44] Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device
    Vieira, SC
    Kaatee, RSJP
    Dirkx, MLP
    Heijmen, BJM
    MEDICAL PHYSICS, 2003, 30 (11) : 2981 - 2987
  • [45] Assessment of Multi-leaf Collimator Positional Accuracy Using Radiochromic EBT3 Film and an Electronic Portal Imaging Device
    Forough Nikeghbali
    Abolfazl Nickfarjam
    Fateme Shirani
    Nouraddin Abdi Goushbolagh
    Nasim Namiranian
    Bagher Farhood
    Masoud Shabani
    Kazem Vakili
    Journal of the Korean Physical Society, 2020, 76 : 795 - 801
  • [46] Quality assurance of MLC leaf position accuracy and relative dose effect at the MLC abutment region using an electronic portal imaging device
    Sumida, Iori
    Yamaguchi, Hajime
    Kizaki, Hisao
    Koizumi, Masahiko
    Ogata, Toshiyuki
    Takahashi, Yutaka
    Yoshioka, Yasuo
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (05) : 798 - 806
  • [47] Assessment of Multi-leaf Collimator Positional Accuracy Using Radiochromic EBT3 Film and an Electronic Portal Imaging Device
    Nikeghbali, Forough
    Nickfarjam, Abolfazl
    Shirani, Fateme
    Goushbolagh, Nouraddin Abdi
    Namiranian, Nasim
    Farhood, Bagher
    Shabani, Masoud
    Vakili, Kazem
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (09) : 795 - 801
  • [48] Deep learning-based 3D in vivo dose reconstruction with an electronic portal imaging device for magnetic resonance-linear accelerators: a proof of concept study
    Li, Yongbao
    Xiao, Fan
    Liu, Biaoshui
    Qi, Mengke
    Lu, Xingyu
    Cai, Jiajun
    Zhou, Linghong
    Song, Ting
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (23)
  • [49] Validation of Three-dimensional Electronic Portal Imaging Device-based PerFRACTION™ Software for Patient-Specific Quality Assurance
    Sait, A. Aziz
    Figueredo, Jason
    Jones, Glenn W.
    Jones, Kai
    McGowan, Thomas
    Kapatoes, Jeff
    Ramaseshan, Ramani
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (01) : 16 - 20
  • [50] Daily organ tracking in intensity-modulated radiotherapy of prostate cancer using an electronic portal imaging device with a dose saving acquisition mode
    Vetterli, Daniel
    Thalmann, Sandrine
    Behrensmeier, Frank
    Kemmerling, Ludger
    Born, Ernst J.
    Mini, Roberto
    Greiner, Richard H.
    Aebersold, Daniel M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (01) : 101 - 108