Imaging linear accelerator output using a high-speed scintillation based electronic portal imaging device (Hi-EPID)

被引:0
作者
Ranade, Manisha [1 ,2 ]
Lynch, Bart [2 ]
Li, Jonathan [2 ]
Kim, Siyong [2 ]
Dempsey, James [2 ]
机构
[1] Univ Florida, Dept Radiat Oncol, 2000 SW Archer Rd, Gainesville, FL 32610 USA
[2] Univ Florida, Gainesville, FL 32611 USA
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6 | 2007年 / 14卷
关键词
Therapy verification; IMRT dose verification; Linear accelerator output measurement; EPID;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a high-speed scintillation based electronic portal imaging device (Hi-EPID) to image the fluence output of a linear accelerator as it exits the head. The Hi-EPID consists of a high speed digital camera coupled with a fast terbium-doped gadolinium-oxy-sulfide (Gd2O2S:Tb) scintillator. The camera can record every single radiation pulse out of the accelerator, at up to 500 frames per second. Since the Hi-EPID allows us to simultaneously obtain both the fluence and the field shape in a delivery, it serves as an independent means of verifying treatment delivery. In this study, we used the Hi-EPID to analyze the characteristics of the fluence delivered from a commercial clinical linear accelerator (Synergy (R) S, Elekta). Both open field and multileaf collimator (MLC) based intensity modulated radiation therapy (IMRT) fields were evaluated. Fluence delivery irregularities were observed with the Hi-EPID device. Fluence was not constant over the duration of a segment, resulting in a varying dose rate. For the open field delivery, the fluence increased with time until it reached a plateau (in approximately 100 ins), remaining constant over the remainder of the delivery. However, in the case of a six segment IMRT field delivery, the fluence variation differed between segments. For some segments, the fluence increased in the beginning and then reached a plateau. For others, the fluence rose and fell sharply, followed by a slower rise to the plateau. The rapid fluence variation before a plateau was as high as 50% of the maximum. Though the total fluence was correctly delivered, this result is intriguing and calls for further investigation. An analysis of field shapes showed no unplanned motion of MLC during step and shoot delivery, as has been reported for another clinical linear accelerator.
引用
收藏
页码:1811 / +
页数:2
相关论文
共 50 条
  • [31] Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software
    Held, Mareike
    Cheung, Joey
    Andujar, Angelica Perez
    Husson, Francois
    Morin, Olivier
    CUREUS, 2018, 10 (02):
  • [32] A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device
    Dunscombe, P
    Humphreys, S
    Leszczynski, K
    MEDICAL PHYSICS, 1999, 26 (02) : 239 - 243
  • [33] Three year experience of electronic portal imaging device based daily QA for photon radiation beams
    Cai, Bin
    He, Yu
    Bollinger, Douglas
    Li, Hua
    Goddu, Sreekrishna M.
    Mutic, Sasa
    Sun, Baozhou
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (01):
  • [34] Evaluation of set-up errors and estimation of set-up margin during external beam radiation therapy of prostate cancer using electronic portal imaging device (EPID)
    Khoramian, Daryoush
    Sistani, Soroush
    Farhood, Bagher
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (04) : 493 - 500
  • [35] Study of X-ray field junction dose using an a-Si electronic portal imaging device
    Madebo, Mebratu
    Perkins, A.
    Fox, C.
    Johnston, P.
    Kron, T.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2010, 33 (01) : 45 - 50
  • [36] Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal imaging device and radiopaque markers
    Kaatee, RSJP
    Olofsen, MJJ
    Verstraate, MBJ
    Quint, S
    Heijmen, BJM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (02): : 576 - 583
  • [37] Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device
    Pasma, KL
    Dirkx, MLP
    Kroonwijk, M
    Visser, AG
    Heijmen, BJM
    MEDICAL PHYSICS, 1999, 26 (11) : 2373 - 2378
  • [38] SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device
    Vieira, SC
    Dirkx, MLP
    Heijmen, BJM
    de Boer, HCJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 981 - 993
  • [39] Evaluation of AutoCAL for electronic portal imaging device-based multi-leaf collimator quality assurance
    Shameem T.J.
    Radiological Physics and Technology, 2016, 9 (1) : 95 - 98
  • [40] Study of X-ray field junction dose using an a-Si electronic portal imaging device
    Mebratu Madebo
    A. Perkins
    C. Fox
    P. Johnston
    T. Kron
    Australasian Physical & Engineering Sciences in Medicine, 2010, 33 : 45 - 50