Imaging linear accelerator output using a high-speed scintillation based electronic portal imaging device (Hi-EPID)

被引:0
|
作者
Ranade, Manisha [1 ,2 ]
Lynch, Bart [2 ]
Li, Jonathan [2 ]
Kim, Siyong [2 ]
Dempsey, James [2 ]
机构
[1] Univ Florida, Dept Radiat Oncol, 2000 SW Archer Rd, Gainesville, FL 32610 USA
[2] Univ Florida, Gainesville, FL 32611 USA
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6 | 2007年 / 14卷
关键词
Therapy verification; IMRT dose verification; Linear accelerator output measurement; EPID;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a high-speed scintillation based electronic portal imaging device (Hi-EPID) to image the fluence output of a linear accelerator as it exits the head. The Hi-EPID consists of a high speed digital camera coupled with a fast terbium-doped gadolinium-oxy-sulfide (Gd2O2S:Tb) scintillator. The camera can record every single radiation pulse out of the accelerator, at up to 500 frames per second. Since the Hi-EPID allows us to simultaneously obtain both the fluence and the field shape in a delivery, it serves as an independent means of verifying treatment delivery. In this study, we used the Hi-EPID to analyze the characteristics of the fluence delivered from a commercial clinical linear accelerator (Synergy (R) S, Elekta). Both open field and multileaf collimator (MLC) based intensity modulated radiation therapy (IMRT) fields were evaluated. Fluence delivery irregularities were observed with the Hi-EPID device. Fluence was not constant over the duration of a segment, resulting in a varying dose rate. For the open field delivery, the fluence increased with time until it reached a plateau (in approximately 100 ins), remaining constant over the remainder of the delivery. However, in the case of a six segment IMRT field delivery, the fluence variation differed between segments. For some segments, the fluence increased in the beginning and then reached a plateau. For others, the fluence rose and fell sharply, followed by a slower rise to the plateau. The rapid fluence variation before a plateau was as high as 50% of the maximum. Though the total fluence was correctly delivered, this result is intriguing and calls for further investigation. An analysis of field shapes showed no unplanned motion of MLC during step and shoot delivery, as has been reported for another clinical linear accelerator.
引用
收藏
页码:1811 / +
页数:2
相关论文
共 50 条
  • [21] Evaluation of set-up errors and determination of set-up margin in pelvic radiotherapy by electronic portal imaging device (EPID)
    Noghreiyan, Vajiheh Vejdani
    Nasseri, Shahrookh
    Anvari, Kazem
    Naji, Maryam
    Momennezhad, Mehdi
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 150 - 156
  • [22] A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device
    Zhang, Jun
    Li, Xiuqing
    Lu, Miaomiao
    Zhang, Qilin
    Zhang, Xile
    Yang, Ruijie
    Chan, Maria F.
    Wen, Junhai
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [23] A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device
    Jun Zhang
    Xiuqing Li
    Miaomiao Lu
    Qilin Zhang
    Xile Zhang
    Ruijie Yang
    Maria F. Chan
    Junhai Wen
    Radiation Oncology, 16
  • [24] Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurements
    Petrovic, Borislava
    Grzadziel, Aleksandra
    Rutonjski, Laza
    Slosarek, Krzysztof
    RADIOLOGY AND ONCOLOGY, 2010, 44 (03) : 199 - 206
  • [25] A regression-based approach to compute the pixels sensitivity map of linear accelerator portal imaging devices
    Ahmad, Mahmoud
    Nourzadeh, Hamidreza
    Siebers, Jeffrey
    MEDICAL PHYSICS, 2021, 48 (08) : 4598 - 4609
  • [26] Clinical Feasibility of Using an Electronic Portal Imaging Device for Position Verification during Conventional Radiotherapy
    Shen, Yuxiaotong
    Zhang, Jie
    Ge, Yun
    Chen, Ying
    Li, Haiwei
    Sun, Wei
    Ji, Mingxi
    Wei, Quanbo
    Cai, Jing
    Li, Bing
    2016 IEEE 10TH INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (NANOMED), 2016, : 99 - 103
  • [27] Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device
    King, Brian W.
    Morf, Daniel
    Greer, Peter B.
    MEDICAL PHYSICS, 2012, 39 (05) : 2839 - 2847
  • [28] Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine
    Zhu, Jinhan
    Chen, Lixin
    Chen, Along
    Luo, Guangwen
    Deng, Xiaowu
    Liu, Xiaowei
    RADIATION ONCOLOGY, 2015, 10
  • [29] Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device
    Zeidan, OA
    Li, JG
    Ranade, M
    Stell, AM
    Dempsey, JF
    MEDICAL PHYSICS, 2004, 31 (03) : 463 - 476
  • [30] Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine
    Jinhan Zhu
    Lixin Chen
    Along Chen
    Guangwen Luo
    Xiaowu Deng
    Xiaowei Liu
    Radiation Oncology, 10