Assessing Errors and Accuracy in Dew-Point Potentiometer and Pressure Plate Extractor Measurements

被引:54
|
作者
Gubiani, Paulo Ivonir [1 ]
Reichert, Jose Miguel [1 ]
Campbell, Colin [2 ]
Reinert, Dalvan Jose [1 ]
Gelain, Neiva Somavilla [1 ]
机构
[1] Univ Fed Santa Maria, Soils Dep, BR-97105900 Santa Maria, RS, Brazil
[2] Decagon Devices Inc, Res & Dev, Pullman, WA 99163 USA
关键词
WATER CHARACTERISTIC CURVES; SOIL; RETENTION;
D O I
10.2136/sssaj2012.0024
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Soil water potential can be determined quickly with a WP4 device, which uses a chilled mirror dew point technique. The instrument can be used to check the soil water potential of samples drained in a porous plate extractor (PPE). However, soil water potential measured in both devices on the same soil sample may not be in agreement, mainly in the wet-end of the water retention curve. This work investigates this problem, and further evaluates how equilibrating soil samples in a PPE with different permeable material at the sample bottom (filter paper [FP], polyester fabric [PE], and synthetic knitwear [SK]) affects the final water potential. Soil samples (soil fraction <2 mm) of an Ultisol and an Oxisol were drained at 0.5 and 1.5 MPa pressure in a PPE and the water potential of these samples was measured in a WP4. Another fraction of the same soil was used to obtain a WP4 water retention curve. The permeable materials caused large differences in water retention at 0.5 MPa pressure (0.006 g g(-1) in the Oxisol and 0.021 g g(-1) in the Ultisol), and the FP allowed more water drainage than PE and SK, indicating the latter two should be avoided when using a PPE to determine water extraction. In both soils, the water potential measured in the WP4 was lower than -0.5 MPa for samples under 0.5 MPa pressure and greater than -1.5 MPa for samples under 1.5 MPa pressure. The increase of residual (fitted minus measured) in the WP4 water retention curve indicated that above -0.7 MPa the precision of WP4 measurements decreased drastically.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [11] Use of a chilled-mirror dew-point potentiometer to determine suction in a railway formation material
    Rorke, L.
    Tripathy, S.
    Otter, L.
    Clayton, C. R. I.
    Powrie, W.
    PROCEEDINGS OF THE FIRST SOUTHERN AFRICAN GEOTECHNICAL CONFERENCE, 2016, : 229 - 235
  • [12] DEW-POINT MEASUREMENTS FOR NITROGEN PROPANE AND NITROGEN BUTANE MIXTURES
    HUDZIAK, JA
    KAHVAND, H
    YASSAIE, M
    LEIPZIGER, S
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1984, 29 (03): : 296 - 301
  • [13] ERRORS ASSOCIATED WITH THE MEASUREMENT OF DEW-POINT LOCI FOR WIDE BOILING MIXTURES
    VEERANNA, D
    HUSAIN, A
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1984, 62 (03): : 434 - 436
  • [14] A NOVEL PHOTONIC DEW-POINT HYGROMETER WITH ULTRA-HIGH ACCURACY
    Tao, Jifang
    Wang, Li
    Cai, Hong
    Sun, Tao
    Song, Junfeng
    Gu, Yuandong
    2016 IEEE 29TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2016, : 893 - 896
  • [15] Gas condensate reservoirs: Characterization and calculation of dew-point pressure
    Alarouj, Mutlaq
    Alomair, Osamah
    Elsharkawy, Adel
    PETROLEUM EXPLORATION AND DEVELOPMENT, 2020, 47 (05) : 1091 - 1102
  • [16] Gas condensate reservoirs: Characterization and calculation of dew-point pressure
    ALAROUJ Mutlaq
    ALOMAIR Osamah
    ELSHARKAWY Adel
    Petroleum Exploration and Development, 2020, 47 (05) : 1091 - 1102
  • [17] A calculation method of dew-point pressure of gas condensate reservoir
    Alarouj M.
    Alomair O.
    Elsharkawy A.
    Shiyou Kantan Yu Kaifa/Petroleum Exploration and Development, 2020, 47 (05): : 1016 - 1026
  • [18] EVALUATION OF WATER ACTIVITY MEASUREMENTS WITH A DEW-POINT ELECTRONIC HUMIDITY METER
    ROA, V
    DEDAZA, MST
    FOOD SCIENCE AND TECHNOLOGY-LEBENSMITTEL-WISSENSCHAFT & TECHNOLOGIE, 1991, 24 (03): : 208 - 213
  • [19] Comparative measurements with sand box, pressure membrane extractor and pressure plate extractor
    Imre, E
    Rajkai, K
    Czap, Z
    Firgi, T
    Telekes, G
    Aradi, L
    UNSATURATED SOILS FOR ASIA, 2000, : 287 - 291
  • [20] Measurement Uncertainty of Dew-Point Temperature in a Two-Pressure Humidity Generator
    L. Lages Martins
    A. Silva Ribeiro
    J. Alves e Sousa
    Alistair B. Forbes
    International Journal of Thermophysics, 2012, 33 : 1568 - 1582