Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling

被引:72
|
作者
Lipczynska, Aleksandra [1 ,2 ]
Kaczmarczyk, Jan [1 ]
Melikov, Arsen K. [2 ]
机构
[1] Silesian Tech Univ, Dept Heating Ventilat & Dust Removal Technol, PL-44100 Gliwice, Poland
[2] Tech Univ Denmark, Dept Civil Engn, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
Personalized ventilation; Radiant cooling; Thermal comfort; Contaminant distribution; Personal exposure; DISPLACEMENT VENTILATION; EVAPORATIVE COOLER; HUMAN RESPONSE; PERFORMANCE; COMFORT; CONJUNCTION; TEMPERATURE; DESIGN; SYSTEM; HEALTH;
D O I
10.1016/j.buildenv.2015.05.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thermal environment and air quality conditions provided with combined system of chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for two occupants. The proposed system was compared with total volume HVAC solutions used today, namely mixing ventilation and chilled ceiling combined with mixing ventilation. The objective of the study was to evaluate whether PV can be the only ventilation system in the rooms equipped with chilled ceiling. The room air temperature was 26 degrees C in cases with traditional systems and 28 degrees C when PV was used. PV supplied air with the temperature of 25 degrees C. PV improved thermal conditions and was up to nearly 10 times more efficient in delivering clean air at workstations than mixing ventilation systems, which resulted in strong protection of occupants from the cross-infection. In the room space outside workstations no substantial differences in thermal environment were found between studied systems. The room air mixing with PV working alone was at the same level as with mixing ventilation. No substantial differences in contaminants' concentration distribution and air-change effectiveness were found between the studied systems in the occupied zone outside workstations. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:603 / 614
页数:12
相关论文
共 50 条
  • [41] PERFORMANCE OF COAXIAL CEILING-MOUNTED PERSONALIZED VENTILATOR FOR COMFORT AND GOOD AIR QUALITY
    Ghaddar, Nesreen
    Ghali, Kamel
    Makhoul, Alain
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 4, 2014,
  • [42] Study of an integrated personalized ventilation and local fan-induced active chilled beam air conditioning system in hot and humid climate
    Sekhar, Chandra
    Zheng, Long
    BUILDING SIMULATION, 2018, 11 (04) : 787 - 801
  • [43] Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system
    Che, Wen Wei
    Tso, Chi Yan
    Sun, Li
    Ip, Danny Y. K.
    Lee, Harry
    Chao, Christopher Y. H.
    Lau, Alexis K. H.
    ENERGY AND BUILDINGS, 2019, 201 : 202 - 215
  • [44] Comparative Study of Numerical Simulation of Indoor Thermal Environment in the Pattern of Personalized Ventilation and Stratum Ventilation
    Liu, Taishun
    Liu, Zeqin
    Li, Ge
    Zuo, Zhenjun
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 785 - 791
  • [45] Energy saving, indoor thermal comfort and indoor air quality evaluation of an office environment using corner impinging jet ventilation
    Ameen, Arman
    Cehlin, Mathias
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Karimipanah, Taghi
    DEVELOPMENTS IN THE BUILT ENVIRONMENT, 2023, 15
  • [46] Comparison of indoor thermal environment of an office with three operational modes of chilled panel and displacement ventilation system
    Zhao, Lei
    Yuan, Feng
    2006 XI'AN INTERNATIONAL CONFERENCE OF ARCHITECTURE AND TECHNOLOGY, PROCEEDINGS: ARCHITECTURE IN HARMONY, 2006, : 713 - 719
  • [47] Mixing ventilation coupled with personalized sinusoidal ventilation: Optimal frequency and flow rate for acceptable air quality
    Al Assaad, Douaa
    Ghali, Kamel
    Ghaddar, Nesreen
    Habchi, Carine
    ENERGY AND BUILDINGS, 2017, 154 : 569 - 580
  • [48] SUBJECTIVE ASSESSMENTS OF THERMAL SENSATION FOR CEILING MOUNTED PERSONALIZED VENTILATION SYSTEM
    Yang, Bin
    Sekhar, Chandra S.
    Melikov, Arsen K.
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 401 - 408
  • [49] Interaction of dynamic indoor environment with moving person and performance of ceiling mounted personalized ventilation system
    Yang, Bin
    Sekhar, Chandra
    INDOOR AND BUILT ENVIRONMENT, 2014, 23 (07) : 920 - 932
  • [50] Optimization of operating parameters for combined impinging jet ventilation and chilled ceiling system using machine learning algorithms
    Qi, Hechuang
    Ye, Xiao
    Du, Peng
    Kang, Yanming
    Zhong, Ke
    JOURNAL OF BUILDING ENGINEERING, 2025, 100