Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling

被引:72
|
作者
Lipczynska, Aleksandra [1 ,2 ]
Kaczmarczyk, Jan [1 ]
Melikov, Arsen K. [2 ]
机构
[1] Silesian Tech Univ, Dept Heating Ventilat & Dust Removal Technol, PL-44100 Gliwice, Poland
[2] Tech Univ Denmark, Dept Civil Engn, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
Personalized ventilation; Radiant cooling; Thermal comfort; Contaminant distribution; Personal exposure; DISPLACEMENT VENTILATION; EVAPORATIVE COOLER; HUMAN RESPONSE; PERFORMANCE; COMFORT; CONJUNCTION; TEMPERATURE; DESIGN; SYSTEM; HEALTH;
D O I
10.1016/j.buildenv.2015.05.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thermal environment and air quality conditions provided with combined system of chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for two occupants. The proposed system was compared with total volume HVAC solutions used today, namely mixing ventilation and chilled ceiling combined with mixing ventilation. The objective of the study was to evaluate whether PV can be the only ventilation system in the rooms equipped with chilled ceiling. The room air temperature was 26 degrees C in cases with traditional systems and 28 degrees C when PV was used. PV supplied air with the temperature of 25 degrees C. PV improved thermal conditions and was up to nearly 10 times more efficient in delivering clean air at workstations than mixing ventilation systems, which resulted in strong protection of occupants from the cross-infection. In the room space outside workstations no substantial differences in thermal environment were found between studied systems. The room air mixing with PV working alone was at the same level as with mixing ventilation. No substantial differences in contaminants' concentration distribution and air-change effectiveness were found between the studied systems in the occupied zone outside workstations. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:603 / 614
页数:12
相关论文
共 50 条
  • [21] Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality
    Melikov, A.
    Ivanova, T.
    Stefanova, G.
    BUILDING AND ENVIRONMENT, 2012, 47 : 100 - 108
  • [22] Effectiveness of contaminant confinement in office spaces equipped with ceiling personalized ventilation system
    Alotaibi, Sorour
    Chakroun, Walid
    Habchi, Carine
    Ghali, Kamel
    Ghaddar, Nesreen
    BUILDING SIMULATION, 2018, 11 (04) : 773 - 786
  • [23] IMPACT OF VENTILATION SYSTEM TYPE ON INDOOR THERMAL ENVIRONMENT AND HUMAN THERMAL COMFORT IN A CEILING COOLING ROOM
    Wu, Xiaozhou
    Liu, Genglin
    Gao, Jie
    Wu, Shuang
    THERMAL SCIENCE, 2022, 26 (4B): : 3271 - 3284
  • [24] Assessment age of air and thermal comfort in a classroom by adopting displacement ventilation with chilled ceiling system
    Shbeeb, Ali Aedan
    Mahdi, Ala'a Abbas
    Hussein, Ahmed Kadhim
    JOURNAL OF ENGINEERING RESEARCH, 2021, 9
  • [25] Evaluation of Integral Effect of Thermal Comfort, Air Quality and Draught Risk for Desks Equipped with Personalized Ventilation Systems
    Conceicao, Eusebio
    Awbi, Hazim
    ENERGIES, 2021, 14 (11)
  • [26] Optimization and operation control for the combined impinging jet ventilation and chilled ceiling system with different cooling loads
    Ye, Xiao
    Xi, Wentao
    Qi, Hechuang
    Zhou, Tianjun
    Gao, Yanfeng
    Kang, Yanming
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2023, 242
  • [27] Assessment of Thermal Comfort and Air Quality of Room Conditions by Impinging Jet Ventilation Integrated with Ductless Personalized Ventilation
    Yang, Bin
    Liu, Pengju
    Liu, Yihang
    Jin, Dacheng
    Wang, Faming
    SUSTAINABILITY, 2022, 14 (19)
  • [28] Performance evaluation of the displacement ventilation combined with evaporative cooled ceiling for a typical office in Beirut
    Younis, Manar
    Ghali, Kamel
    Ghaddar, Nesreen
    ENERGY CONVERSION AND MANAGEMENT, 2015, 105 : 655 - 664
  • [29] Investigation of Thermal Comfort in a Space Conditioned by Liquid Desiccant Membrane Chilled Ceiling/Displacement Ventilation System
    Seblany, Racha
    Ghaddar, Nesreen
    Ghali, Kamel
    Ismail, Nagham
    Simonetti, Marco
    Vincenzo, Fracastoro Giovanni
    Virgone, Joseph
    Zoughaib, Assaad
    THIRD INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN - MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2018, : 85 - 94
  • [30] Optimized selection and operation of the combined chilled ceiling system and displacement ventilation
    Ghaddar, N.
    Ghali, K.
    Saadeh, R.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (15) : 1328 - 1340