Continuous monitoring of a challenging heritage tower in Monza, Italy

被引:60
作者
Saisi, Antonella [1 ,2 ]
Gentile, Carmelo [1 ,2 ]
Ruccolo, Antonello [1 ,2 ]
机构
[1] Politecn Milan, Milan, Italy
[2] ABC, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
关键词
Architectural heritage; Automated modal identification; Closely spaced modes; Environmental effects; Frequency crossing/veering; Masonry towers; HISTORIC BELL-TOWER; DAMAGE DETECTION; IDENTIFICATION; SYSTEMS;
D O I
10.1007/s13349-017-0260-5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A recent survey of the historic complex of "Santa Maria del Carrobiolo" in Monza (Italy) highlighted that two sides of the bell-tower are directly supported by the load-bearing walls of the apse and South aisle of the neighbouring church. After the discovery of the weak structural arrangement of the building, a network of 10 displacement transducers, integrated by five temperature sensors, was installed in the tower to check the opening variation of the main cracks. Subsequently, ambient vibration tests were performed and closely spaced modes with similar mode shapes were clearly identified: since the dynamic characteristics of the tower are quite different from those obtained in past experimental studies of similar structures and conceivably related to the construction sequence, a simple dynamic monitoring system was installed in the tower to complete the health monitoring aimed at the preservation of the historic structure. The paper-after a brief description of the tower and a summary of selected evidences provided by on-site survey, historic research and static monitoring-focuses on the dynamic characteristics identified in the preliminary ambient vibration tests and the main results of 1-year dynamic monitoring. In order to assess the effects of changing temperature on the natural frequencies of the investigated tower, especially in view of the removal of those effects needed for an effective performance assessment, simple correlation studies between modal frequencies and temperature are presented and discussed.
引用
收藏
页码:77 / 90
页数:14
相关论文
共 26 条
  • [1] Allemang R.J., 1982, PROC 1 INT MODAL ANA
  • [2] Semiempirical Formulations for Estimating the Main Frequency of Slender Masonry Towers
    Bartoli, Gianni
    Betti, Michele
    Marra, Antonino Maria
    Monchetti, Silvia
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2017, 31 (04)
  • [3] Benedettini F., 2009, P 27 INT MOD AN C IM
  • [4] Modal identification of output-only systems using frequency domain decomposition
    Brincker, R
    Zhang, LM
    Andersen, P
    [J]. SMART MATERIALS & STRUCTURES, 2001, 10 (03) : 441 - 445
  • [5] Cabboi A., 2013, THESIS
  • [6] From continuous vibration monitoring to FEM-based damage assessment: Application on a stone-masonry tower
    Cabboi, Alessandro
    Gentile, Carmelo
    Saisi, Antonella
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 156 : 252 - 265
  • [7] Automated modal identification and tracking: Application to an iron arch bridge
    Cabboi, Alessandro
    Magalhaes, Filipe
    Gentile, Carmelo
    Cunha, Alvaro
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (01)
  • [8] Cantieni R, 2014, EURODYN, P1493
  • [9] A robust methodology for modal parameters estimation applied to SHM
    Cardoso, Rhara
    Cury, Alexandre
    Barbosa, Flavio
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2017, 95 : 24 - 41
  • [10] Draper NR, 1998, Applied Regression Analysis, V326