Comparison of Primary Stability of Straight-Walled and Tapered Implants Using an Insertion Torque Device

被引:0
作者
Menicucci, Giulio [1 ]
Pachie, Emanuela
Lorenzetti, Massimo
Migliaretti, Giuseppe [2 ]
Carossa, Stefano
机构
[1] Univ Turin, Dipartimento Sci Biomed & Oncol Umana, Sez Riabilitaz Orale & Protesi Maxillofaciale, Sch Dent, I-10126 Turin, Italy
[2] Univ Turin, Dept Publ Hlth & Microbiol, Stat Unit, I-10126 Turin, Italy
关键词
RESONANCE FREQUENCY; TITANIUM IMPLANTS; BONE-DENSITY; IN-VITRO; INTEGRATION; PLACEMENT; BRANEMARK; DIAMETER; MOBILITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Implant geometry has a major impact on insertion torque values and primary stability, and bone engagement during implant insertion differs according to implant morphology. Primary stability of straight-walled and tapered implants was compared using insertion torque monitoring. Materials and Methods: A total of 57 implants (36 straight-walled OSSEOTITE and 21 tapered OSSEOTITE NT) were inserted in 20 patients. Implant torque values and insertion times were recorded, and the data were processed and interpolated to determine torque as a function of time. Results: Tapered implants required less insertion time and a higher insertion torque than straight-walled implants; this provided better primary stability, although the success rate was 86% for tapered and 100% for straight-walled implants. Conclusions: Tapered implants showed better primary stability than straight-walled implants but had a lower success rate. The authors suggest that in low-density bone, in which only a thin dense cortical layer can contribute to primary stability, a higher insertion torque can lead to the destruction of pen-implant bone, compromising osseointegration. Int J Prosthodont 2012;25:465-471.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
[31]   Evaluation of primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement: An In vitro study [J].
Sugiura, Tsutomu ;
Yamamoto, Kazuhiko ;
Horita, Satoshi ;
Murakami, Kazuhiro ;
Kirita, Tadaaki .
CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (03) :471-476
[32]   Primary stability and bone deformation induced by tapered implants in different bone densities: a microtomography and resonance frequency analysis [J].
P. Faria ;
A. Vieta ;
F. A. Oliveira ;
V. F. Carvalho ;
S. L. S. Souza ;
Mario Taba .
Periodontal and Implant Research, 9 (1)
[33]   Immediate loading of fixed partial prostheses reconstructed using either tapered or straight implants in the posterior area: A randomized clinical trial [J].
Kim, Yoo-Yeon ;
Song, Young Woo ;
Kim, Myong Ji ;
Cha, Jae-Kook ;
Park, Ji-Man ;
Kim, Jee-Hwan ;
Jung, Ui-Won .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (05) :703-715
[34]   The Influence of the Implant Macrogeometry on Insertion Torque, Removal Torque, and Periotest Implant Primary Stability: A Mechanical Simulation on High-Density Artificial Bone [J].
Tumedei, Margherita ;
Petrini, Morena ;
Pietropaoli, Davide ;
Cipollina, Alessandro ;
La Torre, Castrenze ;
Di Carmine, Maria Stella ;
Piattelli, Adriano ;
Iezzi, Giovanna .
SYMMETRY-BASEL, 2021, 13 (05)
[35]   Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study [J].
Trisi, Paolo ;
De Benedittis, Simona ;
Perfetti, Giorgio ;
Berardi, Davide .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) :567-570
[36]   Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study [J].
Romero, Marta ;
Herrero-Climent, Mariano ;
Rios-Carrasco, Blanca ;
Brizuela, Aritza ;
Romero, Manuel Maria ;
Gil, Javier .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
[37]   Machine-Driven Versus Manual Insertion Mode: Influence on Primary Stability of Orthodontic Mini-Implants [J].
Novsak, Domen ;
Zrinski, Magda Trinajstic ;
Spalj, Stjepan .
IMPLANT DENTISTRY, 2015, 24 (01) :31-36
[38]   The effects of implant design, bone quality, and insertion process on primary stability of dental implants: an in-vitro study [J].
Rismanchian, Mansour ;
Afshari, Mojtaba .
INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (04) :319-333
[39]   Comparison of Primary Stability of Two Different Implants Designs-A Prospective Clinical Study [J].
Sravanthi, A. Veena ;
Manne, Prakash ;
Surapaneni, Haragopal .
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (01) :ZC16-ZC19
[40]   Insertion and removal torque of dental implants placed using different drilling protocols: An experimental study on artificial bone substitutes [J].
Romeo, Davide ;
Chochlidakis, Konstantinos ;
Barmak, Abdul Basir ;
Agliardi, Enrico ;
Lo Russo, Lucio ;
Ercoli, Carlo .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07) :633-638