Comparison of Primary Stability of Straight-Walled and Tapered Implants Using an Insertion Torque Device

被引:0
作者
Menicucci, Giulio [1 ]
Pachie, Emanuela
Lorenzetti, Massimo
Migliaretti, Giuseppe [2 ]
Carossa, Stefano
机构
[1] Univ Turin, Dipartimento Sci Biomed & Oncol Umana, Sez Riabilitaz Orale & Protesi Maxillofaciale, Sch Dent, I-10126 Turin, Italy
[2] Univ Turin, Dept Publ Hlth & Microbiol, Stat Unit, I-10126 Turin, Italy
关键词
RESONANCE FREQUENCY; TITANIUM IMPLANTS; BONE-DENSITY; IN-VITRO; INTEGRATION; PLACEMENT; BRANEMARK; DIAMETER; MOBILITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Implant geometry has a major impact on insertion torque values and primary stability, and bone engagement during implant insertion differs according to implant morphology. Primary stability of straight-walled and tapered implants was compared using insertion torque monitoring. Materials and Methods: A total of 57 implants (36 straight-walled OSSEOTITE and 21 tapered OSSEOTITE NT) were inserted in 20 patients. Implant torque values and insertion times were recorded, and the data were processed and interpolated to determine torque as a function of time. Results: Tapered implants required less insertion time and a higher insertion torque than straight-walled implants; this provided better primary stability, although the success rate was 86% for tapered and 100% for straight-walled implants. Conclusions: Tapered implants showed better primary stability than straight-walled implants but had a lower success rate. The authors suggest that in low-density bone, in which only a thin dense cortical layer can contribute to primary stability, a higher insertion torque can lead to the destruction of pen-implant bone, compromising osseointegration. Int J Prosthodont 2012;25:465-471.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
  • [21] Primary Stability of Conventionally Tapered Versus Reverse Tapered Body Shift Implants Under Varying Bone Support Conditions-An In-Vitro Study
    Pitman, Jeremy
    Christiaens, Veronique
    Cosyn, Jan
    Glibert, Maarten
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (04) : 429 - 435
  • [22] Primary Stability of Cylindrical and Conical Dental Implants in Relation to Insertion TorqueA Comparative Ex Vivo Evaluation
    Staedt, Henning
    Palarie, Victor
    Staedt, Arne
    Wolf, Jens M.
    Lehmann, Karl Martin
    Ottl, Peter
    Kaemmerer, Peer W.
    [J]. IMPLANT DENTISTRY, 2017, 26 (02) : 250 - 255
  • [23] An In Vitro Analysis on Polyurethane Foam Blocks of the Insertion Torque (IT) Values, Removal Torque Values (RTVs), and Resonance Frequency Analysis (RFA) Values in Tapered and Cylindrical Implants
    Comuzzi, Luca
    Tumedei, Margherita
    D'Arcangelo, Camillo
    Piattelli, Adriano
    Iezzi, Giovanna
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (17)
  • [24] Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks
    Makary, Christian
    Rebaudi, Alberto
    Sammartino, Gilberto
    Naaman, Nada
    [J]. IMPLANT DENTISTRY, 2012, 21 (06) : 474 - 480
  • [25] Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    Kahraman, S.
    Bal, B. T.
    Asar, N. V.
    Turkyilmaz, I.
    Tozum, T. F.
    [J]. JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) : 755 - 761
  • [26] A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single tooth implants under immediate loading
    da Cunha, HA
    Francischone, CE
    Nary, H
    de Oliveira, RCG
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (04) : 578 - 585
  • [27] Evaluation of primary and secondary stability of titanium implants using different surgical techniques
    Tabassum, Afsheen
    Meijer, Gert J.
    Walboomers, X. Frank
    Jansen, John A.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (04) : 487 - 492
  • [28] Investigation to Predict Primary Implant Stability Using Frictional Resistance Torque of Tap Drilling
    Wakamatsu, Kaien
    Doi, Kazuya
    Kobatake, Reiko
    Makihara, Yusuke
    Oki, Yoshifumi
    Tsuga, Kazuhiro
    [J]. JOMR-JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, 2022, 13 (04):
  • [29] Evaluation of primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement: An In vitro study
    Sugiura, Tsutomu
    Yamamoto, Kazuhiko
    Horita, Satoshi
    Murakami, Kazuhiro
    Kirita, Tadaaki
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (03) : 471 - 476
  • [30] Primary stability and bone deformation induced by tapered implants in different bone densities: a microtomography and resonance frequency analysis
    P. Faria
    A. Vieta
    F. A. Oliveira
    V. F. Carvalho
    S. L. S. Souza
    Mario Taba
    [J]. Periodontal and Implant Research, 9 (1)