Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation

被引:81
作者
Ho, WO
Krause, S
McNeil, CJ [1 ]
Pritchard, JA
Armstrong, RD
Athey, D
Rawson, K
机构
[1] Newcastle Univ, Sch Med, Dept Clin Biochem, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Newcastle Univ, Dept Chem, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[3] Univ Sheffield, Dept Chem, Sheffield S3 7HF, S Yorkshire, England
[4] Cambridge Life Sci Plc, Ely CB7 4DT, Cambs, England
关键词
D O I
10.1021/ac981367d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzyme-catalyzed polymer transformation with electrochemical ac impedance detection has been employed for the measurement of urea and creatinine in serum samples. A polymer, based on poly(methylvinyl ether)/maleic anhydride modified by esterification with n-octanol, which is stable at pH 7.4 and which is transformed rapidly in response to alkaline pH changes, was linked to enzymatic reactions between urease and urea or creatinine deiminase and creatinine to produce a disposable sensor system. The polymer was screen-printed onto interdigitated screen-printed carbon electrodes and the electrodes overlaid with absorbent pads containing the relevant enzyme. Application of serum samples, "spiked" with either urea or creatinine, resulted in rapid polymer transformation, and resultant changes in the capacitance of the polymer-coated electrodes were analyte-concentration dependent. Additional information on the mechanisms of polymer transformation was obtained from dynamic quartz crystal microbalance measurements.
引用
收藏
页码:1940 / 1946
页数:7
相关论文
共 19 条
  • [1] ACCIARDO SR, 1992, ASAIO J, pM282
  • [2] Viscoelastic characterization of electroactive polymer films at the electrode/solution interface
    Bandey, HL
    Hillman, AR
    Brown, MJ
    Martin, SJ
    [J]. FARADAY DISCUSSIONS, 1997, 107 : 105 - 121
  • [3] DIRECT DETECTION OF IMMUNOSPECIES BY CAPACITANCE MEASUREMENTS
    BATAILLARD, P
    GARDIES, F
    JAFFREZICRENAULT, N
    MARTELET, C
    COLIN, B
    MANDRAND, B
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (21) : 2374 - 2379
  • [4] A CRITICAL-EVALUATION OF DIRECT ELECTRICAL PROTEIN-DETECTION METHODS
    BERGVELD, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) : 55 - 72
  • [5] A biosensor that uses ion-channel switches
    Cornell, BA
    BraachMaksvytis, VLB
    King, LG
    Osman, PDJ
    Raguse, B
    Wieczorek, L
    Pace, RJ
    [J]. NATURE, 1997, 387 (6633) : 580 - 583
  • [6] GRANATA RD, 1993, AM SOC TEST MATER, V1188, P450, DOI 10.1520/STP18085S
  • [7] MORTALITY AND DURATION OF HEMODIALYSIS-TREATMENT
    HELD, PJ
    LEVIN, NW
    BOVBJERG, RR
    PAULY, MV
    DIAMOND, LH
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (07): : 871 - 875
  • [8] CONTROLLED DRUG RELEASE BY POLYMER DISSOLUTION .1. PARTIAL ESTERS OF MALEIC-ANHYDRIDE COPOLYMERS-PROPERTIES AND THEORY
    HELLER, J
    BAKER, RW
    GALE, RM
    RODIN, JO
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 1978, 22 (07) : 1991 - 2009
  • [9] NADH-DEPENDENT COUPLED ENZYME ASSAY FOR UREASE AND OTHER AMMONIA-PRODUCING SYSTEMS
    KALTWASS.H
    SCHLEGEL, HG
    [J]. ANALYTICAL BIOCHEMISTRY, 1966, 16 (01) : 132 - &
  • [10] Behaviour of pH sensitive polymers on metal electrodes
    Krause, S
    McNeil, CJ
    Armstrong, RD
    Ho, WO
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 1997, 27 (03) : 291 - 298