A low-cost particulate matter (PM2.5) monitor for wildland fire smoke

被引:35
作者
Kelleher, Scott [1 ]
Quinn, Casey [2 ]
Miller-Lionberg, Daniel [1 ]
Volckens, John [1 ]
机构
[1] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Dept Environm & Radiol Hlth Sci, Ft Collins, CO 80523 USA
关键词
OBSTRUCTIVE PULMONARY-DISEASE; LONG-TERM EXPOSURE; AIR-POLLUTION; ORGANIC-COMPOUNDS; PERFORMANCE; POPULATION; ADSORPTION; SENSORS;
D O I
10.5194/amt-11-1087-2018
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Wildfires and prescribed fires produce emissions that degrade visibility and are harmful to human health. Smoke emissions and exposure monitoring is critical for public and environmental health protection; however, ground-level measurements of smoke from wildfires and prescribed fires has proven difficult, as existing (validated) monitoring technologies are expensive, cumbersome, and generally require line power. Few ground-based measurements are made during fire events, which limits our ability to assess the environmental and human health impacts of wildland fire smoke. & para;& para;The objective of this work was to develop and validate an Outdoor Aerosol Sampler (OAS) - a filter-based air sampler that has been miniaturized, solar powered, and weatherproofed. This sampler was designed to overcome several of the technical challenges of wildland fire monitoring by being relatively inexpensive and solar powered. The sampler design objectives were achieved by leveraging low-cost electronic components, open-source programming platforms, and in house fabrication methods. A direct-reading PM2.5 sensor was selected and integrated with the OAS to provide time-resolved concentration data. Cellular communications established via short message service (SMS) technology were utilized in transmitting online sensor readings and controlling the sampling device remotely. A Monte Carlo simulation aided in the selection of battery and solar power necessary to independently power the OAS, while keeping cost and size to a minimum.& para;& para;Thirteen OAS were deployed to monitor smoke concentrations downwind from a large prescribed fire. Aerosol mass concentrations were interpolated across the monitoring network to depict smoke concentration gradients in the vicinity of the fire. Strong concentration gradients were observed (spatially and temporally) and likely present due to a combination of changing fire location and intensity, topographical features (e.g., mountain ridges), and diurnal weather patterns. Gravimetric filter measurements made by the OAS (when corrected for filter collection efficiency) showed relatively good agreement with measurements from an EPA federal equivalent monitor. However, the real-time optical sensor (Sharp GP2Y1023AU0F, Sharp Electronic Co.) within the OAS suffered from temperature dependence, drift, and imprecision.
引用
收藏
页码:1087 / 1097
页数:11
相关论文
共 34 条
  • [1] Particulate size distributed organic: Compounds in a forest atmosphere
    Alves, CA
    Pio, CA
    Duarte, AC
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (20) : 4287 - 4293
  • [2] Long-term exposure to outdoor air pollution and the incidence of chronic obstructive pulmonary disease in a national English cohort
    Atkinson, R. W.
    Carey, I. M.
    Kent, A. J.
    van Staa, T. P.
    Anderson, H. R.
    Cook, D. G.
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2015, 72 (01) : 42 - 48
  • [3] Air pollution and cardiovascular disease - A statement for healthcare professionals from the expert panel on population and prevention science of the American Heart Association
    Brook, RD
    Franklin, B
    Cascio, W
    Hong, YL
    Howard, G
    Lipsett, M
    Luepker, R
    Mittleman, M
    Samet, J
    Smith, SC
    Tager, I
    [J]. CIRCULATION, 2004, 109 (21) : 2655 - 2671
  • [4] Technical note: Performance of a personal electrostatic precipitator particle sampler
    Cardello, N
    Volckens, J
    Tolocka, MP
    Wiener, R
    Buckley, TJ
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2002, 36 (02) : 162 - 165
  • [5] Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements
    Chakrabarti, B
    Fine, PM
    Delfino, R
    Sioutas, C
    [J]. ATMOSPHERIC ENVIRONMENT, 2004, 38 (20) : 3329 - 3340
  • [6] Impact of a cleaner-burning cookstove intervention on blood pressure in Nicaraguan women
    Clark, M. L.
    Bachand, A. M.
    Heiderscheidt, J. M.
    Yoder, S. A.
    Luna, B.
    Volckens, J.
    Koehler, K. A.
    Conway, S.
    Reynolds, S. J.
    Peel, J. L.
    [J]. INDOOR AIR, 2013, 23 (02) : 105 - 114
  • [7] The global burden of disease due to outdoor air pollution
    Cohen, AJ
    Anderson, HR
    Ostro, B
    Pandey, KD
    Krzyzanowski, M
    Künzli, N
    Gutschmidt, K
    Pope, A
    Romieu, I
    Samet, JM
    Smith, K
    [J]. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2005, 68 (13-14): : 1301 - 1307
  • [8] Crilley L. R., 2017, ATMOS MEAS IN PRESS
  • [9] CSU, 2016, CHRIST FIELD WEATH S
  • [10] ENVIRONMENTAL PROTECTION AGENCY, 1998, INT AIR QUAL POL WIL