Adhesion mechanisms of silica layers on plasma-treated polymers .1. Polycarbonate

被引:43
作者
Vallon, S
Hofrichter, A
Guyot, L
Drevillon, B
KlembergSapieha, JE
Martinu, L
PoncinEpaillard, F
机构
[1] ECOLE POLYTECH,PHYS INTERFACES & COUCHES MINCES LAB,UPR 258 CNRS,F-91128 PALAISEAU,FRANCE
[2] ECOLE POLYTECH,DEPT ENGN PHYS,STN CTR VILLE,MONTREAL,PQ H3C 3A7,CANADA
[3] UNIV MAINE,LAB CHIM & PHYSICOCHIM MACROMOL,URA 509 CNRS,F-72017 LE MANS,FRANCE
基金
加拿大自然科学与工程研究理事会;
关键词
adhesion; plasma treatment; polycarbonate; silica; ellipsometry;
D O I
10.1163/156856196X00256
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
We have studied the influence of plasma treatment in various gases (Ar, NH3, N-2) on the surface modification of polycarbonate (PC) and on the adhesion of plasma-deposited silica layers to PC. Surface modification was investigated using in situ IR ellipsometry, X-ray photoelectron spectroscopy, and contact angle measurements interpreted in terms of electron-acceptor/donor groups. In addition, in situ UV-visible ellipsometry enabled crosslinking analysis. Due to UV photon emission, Ar plasma treatment induced crosslinking as well as photo-Fries rearrangements and related reactions, thus creating phenolic groups. These groups are acidic sites and are likely to react with the electronegative oxygen atoms of silica. Adhesion of silica to PC, as measured by the micro-scratch test, was enhanced by Ar plasma treatment. The improvement is attributed to the crosslinking of PC, on the one hand, and to acid-base interactions and/or covalent bonding between PC and silica, on the other hand. A further improvement in adhesion was achieved using N-2 plasma treatments (pure or Ar-diluted). These treatments also induced crosslinking and phenolic group formation and, in addition, nitrogen grafting at the surface. Adhesion enhancement from Ar to N-2 treatments is thus attributed to nitrogen-containing groups, which are likely to promote covalent bonding between silica and the treated polymer surface. In contrast, Ar-diluted NH3 plasma treatment following Ar treatment resulted in decreased adhesion, which is attributed to reduced acidity and low nitrogen grafting.
引用
收藏
页码:1287 / 1311
页数:25
相关论文
共 33 条
[1]   OPTICAL-PROPERTIES OF THIN-FILMS [J].
ASPNES, DE .
THIN SOLID FILMS, 1982, 89 (03) :249-262
[2]   Amperometric glucose sensor based on glucose oxidase immobilized in electrochemically generated poly(ethacridine) [J].
Xu, JJ ;
Chen, HY .
ANALYTICA CHIMICA ACTA, 2000, 423 (01) :101-106
[3]  
BALYO N, 1991, J NONCRYST SOLIDS, V137, P771
[4]  
Beamson G., 1993, Adv. Mater., V5, P778, DOI [DOI 10.1002/ADMA.19930051035, 10.1002/adma.19930051035]
[5]   SURFACE MODIFICATION OF POLYETHYLENE BY REMOTE DC DISCHARGE PLASMA TREATMENT [J].
BEHNISCH, J ;
HOLLANDER, A ;
ZIMMERMANN, H .
JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 49 (01) :117-124
[6]   INSITU STUDY OF THE GROWTH OF HYDROGENATED AMORPHOUS-SILICON BY INFRARED ELLIPSOMETRY [J].
BLAYO, N ;
DREVILLON, B .
APPLIED PHYSICS LETTERS, 1991, 59 (08) :950-952
[7]   NEW DEVELOPMENTS IN THE MODELING OF THE HARDNESS AND SCRATCH ADHESION OF THIN-FILMS [J].
BULL, SJ ;
RICKERBY, DS .
SURFACE & COATINGS TECHNOLOGY, 1990, 42 (02) :149-164
[8]   THE SCRATCH ADHESION TEST - AN ELASTIC-PLASTIC INDENTATION ANALYSIS [J].
BURNETT, PJ ;
RICKERBY, DS .
THIN SOLID FILMS, 1988, 157 (02) :233-254
[9]   PHASE-MODULATED ELLIPSOMETER USING A FOURIER-TRANSFORM INFRARED SPECTROMETER FOR REAL-TIME APPLICATIONS [J].
CANILLAS, A ;
PASCUAL, E ;
DREVILLON, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (08) :2153-2159