Adaption of a conventional ELISA to a 96-well ELISA-Array for measuring the antibody responses to influenza virus proteins and vaccines

被引:8
作者
Waltari, Eric [1 ]
Carabajal, Esteban [1 ]
Sanyal, Mrinmoy [2 ,3 ]
Friedland, Natalia [2 ,3 ]
McCutcheon, Krista M. [1 ]
机构
[1] Chan Zuckerberg Biohub, San Francisco, CA 94158 USA
[2] Stanford Univ, Sch Med, Stanford ChEM H, Stanford, CA 94305 USA
[3] Stanford Univ, Sch Med, Dept Biochem, Stanford, CA 94305 USA
关键词
LINKED-IMMUNOSORBENT-ASSAY; IMMUNE-RESPONSES; IMMUNOGLOBULIN-G; MULTIPLEX ELISA; MICROARRAY; DISCOVERY;
D O I
10.1016/j.jim.2020.112789
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe an adaptation of conventional ELISA methods to an ELISA-Array format using non-contact Piezo printing of up to 30 spots of purified recombinant viral fusion proteins and vaccine on 96 well high-protein binding plates. Antigens were printed in 1 nanoliter volumes of protein stabilizing buffer using as little as 0.25 nanograms of protein, 2000-fold less than conventional ELISA. The performance of the ELISA-Array was demonstrated by serially diluting n = 9 human post-flu vaccination plasma samples starting at a 1/1000 dilution and measuring binding to the array of Influenza antigens. Plasma polyclonal antibody levels were detected using a cocktail of biotinylated anti-human kappa and lambda light chain antibodies, followed by a Streptavidin-horseradish peroxidase conjugate and the dose-dependent signal was developed with a precipitable TMB substrate. Intra- and inter-assay precision of absorbance units among the eight donor samples showed mean CVs of 4.8% and 10.8%, respectively. The plasma could be differentiated by donor and antigen with titer sensitivities ranging from 1 × 103 to 4 × 106, IC50 values from 1 × 104 to 9 × 106, and monoclonal antibody sensitivities in the ng/mL range. Equivalent sensitivities of ELISA versus ELISA-Array, compared using plasma and an H1N1 HA trimer, were achieved on the ELISA-Array printed at 0.25 ng per 200um spot and 1000 ng per ELISA 96-well. Vacuum-sealed array plates were shown to be stable when stored for at least 2 days at ambient temperature and up to 1 month at 4–8 °C. By the use of any set of printed antigens and analyte matrices the methods of this multiplexed ELISA-Array format can be broadly applied in translational research. © 2020 The Authors
引用
收藏
页数:11
相关论文
共 35 条
[11]  
ENGVALL E, 1972, J IMMUNOL, V109, P129
[12]   Investigating Colorimetric Protein Array Assay Schemes for Detection of Recurrence of Bladder Cancer [J].
Gogalic, Selma ;
Sauer, Ursula ;
Doppler, Sara ;
Preininger, Claudia .
BIOSENSORS-BASEL, 2018, 8 (01)
[13]   Integration of Antibody Array Technology into Drug Discovery and Development [J].
Huang, Wei ;
Whittaker, Kelly ;
Zhang, Huihua ;
Wu, Jian ;
Zhu, Si-Wei ;
Huang, Ruo-Pan .
ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2018, 16 (02) :74-95
[14]   Protein Array-based Approaches for Biomarker Discovery in Cancer [J].
Huang, Yi ;
Zhu, Heng .
GENOMICS PROTEOMICS & BIOINFORMATICS, 2017, 15 (02) :73-81
[15]   Structure and Function Analysis of an Antibody Recognizing All Influenza A Subtypes [J].
Kallewaard, Nicole L. ;
Corti, Davide ;
Collins, Patrick J. ;
Neu, Ursula ;
McAuliffe, Josephine M. ;
Benjamin, Ebony ;
Wachter-Rosati, Leslie ;
Palmer-Hill, Frances J. ;
Yuan, Andy Q. ;
Walker, Philip A. ;
Vorlaender, Matthias K. ;
Bianchi, Siro ;
Guarino, Barbara ;
De Marco, Anna ;
Vanzetta, Fabrizia ;
Agatic, Gloria ;
Foglierini, Mathilde ;
Pinna, Debora ;
Fernandez-Rodriguez, Blanca ;
Fruehwirth, Alexander ;
Silacci, Chiara ;
Ogrodowicz, Roksana W. ;
Martin, Stephen R. ;
Sallusto, Federica ;
Suzich, JoAnn A. ;
Lanzavecchia, Antonio ;
Zhu, Qing ;
Gamblin, Steven J. ;
Skehel, John J. .
CELL, 2016, 166 (03) :596-608
[16]   Development of an ELISA-array for simultaneous detection of five encephalitis viruses [J].
Kang, Xiaoping ;
Li, Yuchang ;
Fan, Li ;
Lin, Fang ;
Wei, Jingjing ;
Zhu, Xiaolei ;
Hu, Yi ;
Li, Jing ;
Chang, Guohui ;
Zhu, Qingyu ;
Liu, Hong ;
Yang, Yinhui .
VIROLOGY JOURNAL, 2012, 9
[17]   Antibody-dependent enhancement of severe dengue disease in humans [J].
Katzelnick, Leah C. ;
Gresh, Lionel ;
Halloran, M. Elizabeth ;
Carlos Mercado, Juan ;
Kuan, Guillermina ;
Gordon, Aubree ;
Balmaseda, Angel ;
Harris, Eva .
SCIENCE, 2017, 358 (6365) :929-932
[18]   A new point-of-care test for the diagnosis of infectious diseases based on multiplex lateral flow immunoassays [J].
Kim, Hanbi ;
Chung, Doo-Ryeon ;
Kang, Minhee .
ANALYST, 2019, 144 (08) :2460-2466
[19]   Multiplexed protein measurement: technologies and applications of protein and antibody arrays [J].
Kingsmore, SF .
NATURE REVIEWS DRUG DISCOVERY, 2006, 5 (04) :310-320
[20]   Profiling of humoral immune responses to influenza viruses by using protein microarray [J].
Koopmans, M. ;
de Bruin, E. ;
Godeke, G-J ;
Friesema, I. ;
van Gageldonk, R. ;
Schipper, M. ;
Meijer, A. ;
van Binnendijk, R. ;
Rimmelzwaan, G. F. ;
de Jong, M. D. ;
Buisman, A. ;
van Beek, J. ;
van de Vijver, D. ;
Reimerink, J. .
CLINICAL MICROBIOLOGY AND INFECTION, 2012, 18 (08) :797-807