Noninvasive Control of the Power Transferred to an Implanted Device by an Ultrasonic Transcutaneous Energy Transfer Link

被引:27
作者
Shmilovitz, Doron [1 ]
Ozeri, Shaul [1 ]
Wang, Chua-Chin [2 ]
Spivak, Boaz [1 ]
机构
[1] Tel Aviv Univ, Sch Elect Engn, IL-69978 Tel Aviv, Israel
[2] Natl Sun Yat Sen Univ, Kaohsiung 80424, Taiwan
关键词
Contactless power transfer; hysteresis control; implanted medical device; ultrasonic transcutaneous energy transfer; voltage regulation; TISSUE; AIR;
D O I
10.1109/TBME.2013.2280460
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasonic transcutaneous energy transfer is an effective method for powering implanted devices noninvasively. Nevertheless, the amount of power harvested by the implanted receiver is sensitive to the distance and orientation of the external transmitting transducer attached to the skin with respect to the implanted receiving transducer. This paper describes an ultrasonic power transfer link whose harvested power is controlled by an inductive link. A small (5 mu F) storage capacitor voltage, which is part of the implanted unit, is allowed to swing between 3.8 and 3.5 V using hysteretic control. The two control states are indicated by excitation (while the implanted storage capacitor voltage decreases) or the absence of excitation of an implanted coil that is magnetically coupled to an external coil attached to the skin surface. A 35 mW Ultrasonic Transcutaneous Energy Transfer link was fabricated using two piezoelectric transducers of equal size (Fuji Ceramics C-2 PZT disc 15 mm x 3 mm) operated at a vibration frequency of 720 kHz. By applying the proposed hysteretic control, the captured power was effectively regulated for implantation depths of up to 85 mm.
引用
收藏
页码:995 / 1004
页数:10
相关论文
共 21 条
  • [1] Energy Efficiency and Reliability in Wireless Biomedical Implant Systems
    Abouei, Jamshid
    Brown, J. David
    Plataniotis, Konstantinos N.
    Pasupathy, Subbarayan
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (03): : 456 - 466
  • [2] Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
    Baker, Michael W.
    Sarpeshkar, Rahul
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2007, 1 (01) : 28 - 38
  • [3] The sensitivity of biological tissue to ultrasound
    Barnett, SB
    Rott, HD
    terHaar, GR
    Ziskin, MC
    Maeda, K
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) : 805 - 812
  • [4] Blackstock D.T., 2000, PHYS ACOUSTICS
  • [5] Transcutaneous powering of implantable micro-stimulators for functional restoration of impaired gastrointestinal motility
    Doherty, JA
    Jullien, GA
    Mintchev, MP
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1575 - 1578
  • [6] Duck FA, 1998, ULTRASOUND MED, P73
  • [7] Frequency-dependent skin-effect formulation for resistance and internal inductance of a solid cylindrical conductor
    Gatous, OM
    Pissolato, J
    [J]. IEE PROCEEDINGS-MICROWAVES ANTENNAS AND PROPAGATION, 2004, 151 (03) : 212 - 216
  • [8] Modeling and Optimization of Printed Spiral Coils in Air, Saline, and Muscle Tissue Environments
    Jow, Uei-Ming
    Ghovanloo, Maysam
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2009, 3 (05) : 339 - 347
  • [9] NEW EQUIVALENT CIRCUITS FOR ELEMENTARY PIEZOELECTRIC TRANSDUCERS
    KRIMHOLTZ, R
    LEEDOM, DA
    MATTHAEI, GL
    [J]. ELECTRONICS LETTERS, 1970, 6 (13) : 398 - +
  • [10] Ozeri S., 2012, P IEEE INT S IND EL, P1153