The Effects of Tenascin C Knockdown on Trabecular Meshwork Outflow Resistance

被引:24
作者
Keller, Kate E. [1 ]
Vranka, Janice A. [1 ]
Haddadin, Ramez I. [2 ]
Kang, Min-Hyung [2 ]
Oh, Dong-Jin [2 ]
Rhee, Douglas J. [2 ]
Yang, Yong-feng [1 ]
Sun, Ying Ying [1 ]
Kelley, Mary J. [1 ]
Acott, Ted S. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
[2] Harvard Univ, Massachusetts Eye & Ear Infirm, Sch Med, Boston, MA USA
关键词
tenascin C; trabecular meshwork; outflow resistance; extracellular matrix; EXTRACELLULAR-MATRIX TURNOVER; LOWER INTRAOCULAR-PRESSURES; OPEN-ANGLE GLAUCOMA; HEPARIN-II DOMAIN; JUXTACANALICULAR TISSUE; MATRICELLULAR PROTEINS; ANTERIOR SEGMENTS; AQUEOUS OUTFLOW; ORGAN-CULTURE; CELL-FUNCTION;
D O I
10.1167/iovs.13-11620
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Tenascin C (TNC) is a matricellular glycoprotein whose expression in adult tissue is indicative of tissue remodeling. The purpose of the current study was to determine the localization of TNC in trabecular meshwork (TM) tissue and to analyze the effects of TNC on intraocular pressure (IOP). METHODS. Human TM frontal sections were immunostained with anti-TNC and imaged by confocal microscopy. TNC mRNA and protein levels were quantitated in anterior segments perfused at physiological and elevated pressure. Short, hairpin RNA (shRNA) silencing lentivirus targeting full-length TNC (shTNC) was applied to anterior segment perfusion organ cultures. The IOPs and central corneal thickness (CCT) of wild-type, TNC-/-, and tenascin X (TNX-/-) knockout mice were measured. RESULTS. TNC was distributed in the juxtacanalicular (JCT) region of adult human TM, predominantly in the basement membrane underlying the inner wall of Schlemm's canal. Application of shTNC lentivirus to human and porcine anterior segments in perfusion culture did not significantly affect outflow rate. Although TNC was upregulated in response to pressure, there was no difference in outflow rate when shTNC-silenced anterior segments were subjected to elevated pressure. Furthermore, IOPs and CCTs were not significantly different between TNC-/- or TNX-/- and wild-type mice. CONCLUSIONS. TNC does not appear to contribute directly to outflow resistance. However, TNC immunolocalization in the JCT of adult human eyes suggests that certain areas of the TM are being continuously remodeled with or without an IOP increase.
引用
收藏
页码:5613 / 5623
页数:11
相关论文
共 59 条
[1]   Extracellular matrix in the trabecular meshwork [J].
Acott, Ted S. ;
Kelley, Mary J. .
EXPERIMENTAL EYE RESEARCH, 2008, 86 (04) :543-561
[2]  
ACOTT TS, 1988, INVEST OPHTH VIS SCI, V29, P90
[3]  
Acott TS, 2010, ENCY EYE, P170
[4]   Specialized Podosome- or Invadopodia-like Structures (PILS) for Focal Trabecular Meshwork Extracellular Matrix Turnover [J].
Aga, Mini ;
Bradley, John M. ;
Keller, Kate E. ;
Kelley, Mary J. ;
Acott, Ted S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (12) :5353-5365
[5]   Twenty-four-hour pattern of mouse intraocular pressure [J].
Aihara, M ;
Lindsey, JD ;
Weinreb, RN .
EXPERIMENTAL EYE RESEARCH, 2003, 77 (06) :681-686
[6]   Matricellular proteins: extracellular modulators of cell function [J].
Bornstein, P ;
Sage, EH .
CURRENT OPINION IN CELL BIOLOGY, 2002, 14 (05) :608-616
[7]  
Bradley JMB, 1998, INVEST OPHTH VIS SCI, V39, P2649
[8]  
Bradley JMB, 2001, INVEST OPHTH VIS SCI, V42, P1505
[9]   The role of SPARC in extracellular matrix assembly [J].
Bradshaw, Amy D. .
JOURNAL OF CELL COMMUNICATION AND SIGNALING, 2009, 3 (3-4) :239-246
[10]  
Brandt James D, 2004, Curr Opin Ophthalmol, V15, P85, DOI 10.1097/00055735-200404000-00004