Effect of geometrical parameters on high frequency performance of Rogowski coil for partial discharge measurements

被引:54
|
作者
Shafiq, Muhammad [1 ]
Hussain, G. Amjad [1 ]
Kutt, Lauri [1 ]
Lehtonen, Matti [1 ]
机构
[1] Aalto Univ, Sch Elect Engn, Dept Elect Engn, FI-00076 Aalto, Finland
关键词
Partial discharge; Rogowski coil; High frequency measurements; Online condition monitoring; Sensitivity; Resonant frequency;
D O I
10.1016/j.measurement.2013.11.048
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Partial discharges (PD) in a power system component is a sever threat, indicating a high likelihood of the imminent and complete failure of the insulation. The reliability of partial discharge diagnostics depends upon the design and accuracy of the measuring sensors. In this paper the Rogowski coil is employed as a PD measuring sensor. The selection of suitable geometrical parameters has been identified as an important aspect regarding the proper operation and installation of the coil around the under test power component. These parameters significantly affect the measuring performance of the coil in terms of its sensitivity and bandwidth. The measurement performance of different geometrical designs for the high frequency Rogowski coils is evaluated. The variation in parameters such as core and coil diameter, diameter of the copper wire used for winding and number of turns, has been experimentally investigated. In addition the return winding, as a non-conventional method of creating a return loop for the Rogowski coil, is compared with a return wire (loop) to analyze sensor performance. The comparative study of variation in mechanical design features provides a brief guideline to select the optimal design of the coil. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:126 / 137
页数:12
相关论文
共 50 条
  • [21] Some considerations of designing a high performance Rogowski coil for pulsed current measurement
    College of Electrical and Electronic Engineering, HuaZhong University of Science and Technology, Wuhan, 430074, China
    Istanb. Univ. J. Electr. Electron. Eng., 2006, 1 (7-12):
  • [22] A Sensitivity Comparison of Low-cost Rogowski Coil Sensors for Partial Discharge Measurement of Molded Power Transformers
    Kim, Sung-Wook
    Kim, Nam-Hoon
    Lee, Gyeong-Yeol
    Kil, Gyung-Suk
    2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2022, : 541 - 544
  • [23] SOME CONSIDERATIONS OF DESIGNING A HIGH PERFORMANCE ROGOWSKI COIL FOR PULSED CURRENT MEASUREMENT
    Li Weibo
    Mao Chengxiong
    Lu Jiming
    ISTANBUL UNIVERSITY-JOURNAL OF ELECTRICAL AND ELECTRONICS ENGINEERING, 2006, 6 (01): : 7 - 12
  • [24] Self-integrated Rogowski coil for low-frequency high current measurement
    Wei B.
    Qing Y.
    Guan Y.
    Qiu X.
    Fu J.
    Song S.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (09): : 2227 - 2231
  • [25] Correlation between geometrical parameters of electrical tree and corresponding partial discharge parameters in XLPE
    Wang, Hong-Xin
    Cheng, Shu-Kang
    Wen, Xi-Shan
    Sun, Xiong-Fei
    Chen, Yun-Ping
    Wuhan University Journal of Natural Sciences, 2004, 9 (03) : 332 - 338
  • [26] Correlation Between Geometrical Parameters of Electrical Tree and Corresponding Partial Discharge Parameters in XLPE
    Wang Hong-xin 1
    2. College of Electrical Engineering
    WuhanUniversityJournalofNaturalSciences, 2004, (03) : 332 - 338
  • [27] Sigma-Delta ADC Topology Implementation Based on Partial Discharge Detection using Rogowski Coil Sensor
    Rohani, M. N. K. H.
    Isa, M.
    Syahril, M.
    Yii, C. C.
    Rosmi, A. S.
    Ismail, B.
    1ST INTERNATIONAL CONFERENCE ON GREEN AND SUSTAINABLE COMPUTING (ICOGES) 2017, 2018, 1019
  • [28] EFFECT OF A MAGNETIC FIELD ON PARAMETERS OF A HIGH-FREQUENCY DISCHARGE
    VAGNER, SD
    KRYLOV, NA
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1966, 10 (08): : 1105 - &
  • [29] PROBE MEASUREMENTS FOR HIGH FREQUENCY DISCHARGE
    KOJIMA, S
    TAKAYAMA, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1949, 4 (4-6) : 349 - 350
  • [30] Influence of High Frequency Current Transformers Bandwidth on Charge Evaluation in Partial Discharge Measurements
    Rodrigo, A.
    Llovera, P.
    Fuster, V.
    Quijano, A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1798 - 1802