Influence of asynchronous demand behavior on overcooling in multiple zone AC systems

被引:13
作者
Zhou, Xin [1 ]
Yan, Da [2 ]
Jiang, Yi [2 ]
Shi, Xing [1 ]
机构
[1] Southeast Univ, Sch Architecture, Nanjing 210096, Jiangsu, Peoples R China
[2] Tsinghua Univ, Sch Architecture, Beijing 100084, Peoples R China
关键词
Asynchronous demand behavior; Overcooling; Gini index; Multiple zone AC systems; AIR-CONDITIONING SYSTEM; THERMAL COMFORT; OFFICE ENVIRONMENT; ENERGY-CONSUMPTION; HVAC SYSTEMS; SIMULATION; BUILDINGS; THERMOSTATS; WORKERS; DESIGN;
D O I
10.1016/j.buildenv.2016.10.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The cooling demands of different zones in an air conditioning (AC) system are different (with large discrepancies) even at the same moment, and the degree of variance changes with time. This asynchronous behavior of demand greatly influences the overcooling degree in multiple zone AC systems. This paper describes the asynchronous demand quantitatively and reveals its relationship with the overcooling degree in a multiple zone AC system. The Lorenz curve and Gini index are introduced in this study and used to describe the demand characteristics. Two typical multiple zone AC systems, namely, constant air volume (CAV) and variable air volume (VAV) systems, are considered as examples, and their overcooling degree under different demand profiles are analyzed. Under different asynchronous demands, the overcooling degree in the CAV system changes from 1 to 3.5, while that in the VAV system changes from 1 to 1.5. In this paper, the influence of the regulation ability of the AC system on energy consumption is also discussed. This paper presents a new perspective to study the demand pattern and explores the method to reduce the overcooling phenomenon in multiple zone AC systems. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 52 条
  • [1] Theory and applications of HVAC control systems - A review of model predictive control (MPC)
    Afram, Abdul
    Janabi-Sharifi, Farrokh
    [J]. BUILDING AND ENVIRONMENT, 2014, 72 : 343 - 355
  • [2] [Anonymous], 2012, ANN EN OUTL 2012 EAR
  • [3] [Anonymous], 2012, WORLD EN BAL 2012
  • [4] [Anonymous], 2002, QUANTIFYING EFFECTS
  • [5] Effects of diffuser airflow minima on occupant comfort, air mixing, and building energy use (RP-1515)
    Arens, Edward
    Zhang, Hui
    Hoyt, Tyler
    Kaam, Soazig
    Bauman, Fred
    Zhai, Yongchao
    Paliaga, Gwelen
    Stein, Jeff
    Seidl, Reinhard
    Tully, Brad
    Rimmer, Julian
    Toftum, Jorn
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (08) : 1075 - 1090
  • [6] Achieving informed decision-making for net zero energy buildings design using building performance simulation tools
    Attia, Shady
    De Herde, Andre
    Gratia, Elisabeth
    Hensen, Jan L. M.
    [J]. BUILDING SIMULATION, 2013, 6 (01) : 3 - 21
  • [7] Simulation comparison of VAV and VRF air conditioning systems in an existing building for the cooling season
    Aynur, Tolga N.
    Hwang, Yunho
    Radermacher, Reinhard
    [J]. ENERGY AND BUILDINGS, 2009, 41 (11) : 1143 - 1150
  • [8] Bannister P., 2008, 2008 ACEEE SUMMER ST
  • [9] Experimental evaluation of occupancy-based energy-efficient climate control of VAV terminal units
    Brooks, Jonathan
    Goyal, Siddharth
    Subramany, Rahul
    Lin, Yashen
    Liao, Chenda
    Middelkoop, Timothy
    Ingley, Herbert
    Arpan, Laura
    Barooah, Prabir
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (04) : 469 - 480
  • [10] Individual and district heating: A comparison of residential heating modes with an analysis of adaptive thermal comfort
    Cao, Bin
    Zhu, Yingxin
    Li, Min
    Ouyang, Qin
    [J]. ENERGY AND BUILDINGS, 2014, 78 : 17 - 24