Volume self-calibration for 3D particle image velocimetry

被引:469
作者
Wieneke, B. [1 ]
机构
[1] LaVis GmbH, D-37081 Gottingen, Germany
关键词
D O I
10.1007/s00348-008-0521-5
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Planar self-calibration methods have become standard for stereo PIV to correct misalignments between laser light sheet and calibration plane. Computing cross-correlation between images from camera 1 and 2 taken at the same time, non-zero disparity vectors indicate rotational and translational misalignments relative to the coordinate system defined by a calibration plate. This approach works well for thin light sheets but fails for extended volumes recorded in 3D-PTV or tomographic PIV experiments. Here it is primarily necessary to correct calibration errors leading to triangulation errors in 3D-PTV or in degraded tomographic volume reconstruction. Tomographic PIV requires calibration accuracies of a fraction of a pixel throughout the complete volume, which is difficult to achieve experimentally. A new volumetric self-calibration technique has been developed based on the computation of the 3D position of matching particles by triangulation as in 3D-PTV. The residual triangulation error ('disparity') is then used to correct the mapping functions for all cameras. A statistical clustering method suitable for dense particle images has been implemented to find correct disparity map peaks from true particle matches. Disparity maps from multiple recordings are summed for better statistics. This self-calibration scheme has been validated using several tomographic PIV experiments improving the vector quality significantly. The relevance for other 3D velocimetry methods is discussed.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
[41]   3D particle streak velocimetry by defocused imaging [J].
Dong, Xiangrui ;
Wang, Xiaoxiao ;
Zhou, Wu ;
Wang, Fangting ;
Tang, Xinran ;
Cai, Xiaoshu .
PARTICUOLOGY, 2023, 72 :1-9
[42]   A simple calibration technique for stereoscopic particle image velocimetry [J].
Andreas Fouras ;
Jonathan Dusting ;
Kerry Hourigan .
Experiments in Fluids, 2007, 42 :799-810
[43]   A simple calibration technique for stereoscopic particle image velocimetry [J].
Fouras, Andreas ;
Dusting, Jonathan ;
Hourigan, Kerry .
EXPERIMENTS IN FLUIDS, 2007, 42 (05) :799-810
[44]   Real-time 3D thermoacoustic imaging and thermometry using a self-calibration technique [J].
Tamimi, Ehab A. ;
Xin, Hao ;
Witte, Russell S. .
APPLIED OPTICS, 2020, 59 (22) :G255-G261
[45]   3D Head Pose Estimation in Monocular Video Sequences by Sequential Camera Self-Calibration [J].
Marras, Ioannis ;
Nikolaidis, Nikos ;
Pitas, Ioannis .
2009 IEEE INTERNATIONAL WORKSHOP ON MULTIMEDIA SIGNAL PROCESSING (MMSP 2009), 2009, :68-73
[46]   Accurate Self-calibration of Camera with Variable Intrinsic Parameters from Unknown 3D Scene [J].
El Batteoui, I. ;
Saaidi, A. ;
Satori, K. .
3D RESEARCH, 2015, 6 (03)
[47]   Online Self-Calibration of 3D Measurement Sensors Using a Voxel-Based Network [J].
Song, Jingyu ;
Lee, Joonwoong .
SENSORS, 2022, 22 (17)
[48]   A genetic algorithm particle pairing technique for 3D velocity field extraction in holographic particle image velocimetry [J].
J. Sheng ;
H. Meng .
Experiments in Fluids, 1998, 25 :461-473
[49]   Automatic Extrinsic Self-Calibration of Mobile Mapping Systems Based on Geometric 3D Features [J].
Hillemann, Markus ;
Weinmann, Martin ;
Mueller, Markus S. ;
Jutzi, Boris .
REMOTE SENSING, 2019, 11 (16)
[50]   Photogrammetric Bundle Adjustment With Self-Calibration of the PrimeSense 3D Camera Technology: Microsoft Kinect [J].
Chow, Jacky C. K. ;
Lichti, Derek D. .
IEEE ACCESS, 2013, 1 :465-474