A Spartan 6 FPGA-based data acquisition system for dedicated imagers in nuclear medicine

被引:14
作者
Fysikopoulos, E. [1 ,2 ]
Loudos, G. [2 ]
Georgiou, M. [2 ,3 ]
David, S. [2 ]
Matsopoulos, G. [1 ]
机构
[1] Natl Tech Univ Athens, Sch Elect & Comp Engn, Athens, Greece
[2] Technol Educ Inst Athens, Dept Med Instruments Technol, Athens, Greece
[3] Univ Thessaly, Sch Med, Dept Nucl Med, Larisa, Greece
关键词
field programmable gate array (FPGA); position-sensitive photomultiplier tube (PSPMT); silicon photomultiplier (SiPM); embedded development kit (EDK); data acquisition (DAQ);
D O I
10.1088/0957-0233/23/12/125403
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We present the development of a four-channel low-cost hardware system for data acquisition, with application in dedicated nuclear medicine imagers. A 12 bit octal channel high-speed analogue to digital converter, with up to 65 Msps sampling rate, was used for the digitization of analogue signals. The digitized data are fed into a field programmable gate array (FPGA), which contains an interface to a bank of double data rate 2 (DDR2)-type memory. The FPGA processes the digitized data and stores the results into the DDR2. An ethernet link was used for data transmission to a personal computer. The embedded system was designed using Xilinx's embedded development kit (EDK) and was based on Xilinx's Microblaze soft-core processor. The system has been evaluated using two different discrete optical detector arrays (a position-sensitive photomultiplier tube and a silicon photomultiplier) with two different pixelated scintillator arrays (BGO, LSO:Ce). The energy resolution for both detectors was approximately 25%. A clear identification of all crystal elements was achieved in all cases. The data rate of the system with this implementation can reach 60 Mbits s(-1). The results have shown that this FPGA data acquisition system is a compact and flexible solution for single-photon-detection applications.
引用
收藏
页数:5
相关论文
共 18 条
  • [1] [Anonymous], MICR PROC REF GUID U
  • [2] [Anonymous], 2008, 12 BIT OCT CHANN ADC
  • [3] Bousselham A, 2007, THESIS STOCKHOLM U S
  • [4] David S, 2011, IEEE NUCL SCI CONF R, P1886, DOI 10.1109/NSSMIC.2011.6154380
  • [5] Dunkels A., 2001, DESIGN IMPLEMENTATIO
  • [6] Georgiou M, 2011, IEEE NUCL SCI CONF R, P4020, DOI 10.1109/NSSMIC.2011.6153764
  • [7] Development of an FPGA-based data acquisition module for small animal PET
    Imrek, J.
    Novak, D.
    Hegyesi, Gy.
    Kalinka, G.
    Molnar, J.
    Vegh, J.
    Balkay, L.
    Emri, M.
    Molnar, G.
    Tron, L.
    Bagamery, I.
    Bukki, T.
    Rozsa, S.
    Szabo, Zs.
    Kerek, A.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2698 - 2703
  • [8] Compact readout electronics for position sensitive photomultiplier tubes
    Olcott, PD
    Talcott, JA
    Levin, CS
    Habte, F
    Foudray, AMK
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 21 - 27
  • [9] Popov V., 2003, NUCL SCI S C RECORD, V3, P2156, DOI DOI 10.1109/NSSMIC.2003.1352307
  • [10] Proffitt J, 2005, IEEE NUCL SCI CONF R, P2971