Application of miniaturized near-infrared spectroscopy for quality control of extemporaneous orodispersible films

被引:16
作者
Foo, Wen Chin [1 ]
Widjaja, Effendi [2 ,3 ]
Khong, Yuet Mei [2 ,4 ]
Gokhale, Rajeev [2 ,5 ]
Chan, Sui Yung [1 ]
机构
[1] Natl Univ Singapore, Dept Pharm, Fac Sci, Singapore 117543, Singapore
[2] AbbVie Singapore Pte Ltd, Singapore 138588, Singapore
[3] MSD Int GmbH, 50 Tuas West Dr, Singapore 638408, Singapore
[4] AbbVie Inc, N Chicago, IL 60064 USA
[5] Roquette Singapore Pte Ltd, Singapore 138667, Singapore
关键词
Near-infrared spectroscopy; Quality control; Orodispersible film; Pharmacy compounding; Identification; Quantification; QUANTIFICATION; IDENTIFICATION; FORMULATIONS; DRUG;
D O I
10.1016/j.jpba.2017.11.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Extemporaneous oral preparations are routinely compounded in the pharmacy due to a lack of suitable formulations for special populations. Such small-scale pharmacy preparations also present an avenue for individualized pharmacotherapy. Orodispersible films (ODF) have increasingly been evaluated as a suitable dosage form for extemporaneous oral preparations. Nevertheless, as with all other extemporaneous preparations, safety and quality remain a concern. Although the United States Pharmacopeia (USP) recommends analytical testing of compounded preparations for quality assurance, pharmaceutical assays are typically not routinely performed for such non-sterile pharmacy preparations, due to the complexity and high cost of conventional assay methods such as high performance liquid chromatography (HPLC). Spectroscopic methods including Raman, infrared and near-infrared spectroscopy have been successfully applied as quality control tools in the industry. The state-of-art benchtop spectrometers used in those studies have the advantage of superior resolution and performance, but are not suitable for use in a small-scale pharmacy setting. In this study, we investigated the application of a miniaturized near infrared (NIR) spectrometer as a quality control tool for identification and quantification of drug content in extemporaneous ODFs. Miniaturized near infrared (NIR) spectroscopy is suitable for small-scale pharmacy applications in view of its small size, portability, simple user interface, rapid measurement and real-time prediction results. Nevertheless, the challenge with miniaturized NIR spectroscopy is its lower resolution compared to state-of-art benchtop equipment. We have successfully developed NIR spectroscopy calibration models for identification of ODFs containing five different drugs, and quantification of drug content in ODFs containing 2-10 mg ondansetron (OND). The qualitative model for drug identification produced 100% prediction accuracy. The quantitative model to predict OND drug content in ODFs was divided into two calibrations for improved accuracy: Calibration I and II covered the 2-4 mg and 4-10 mg ranges respectively. Validation was performed for method accuracy, linearity and precision. In conclusion, this study demonstrates the feasibility of miniaturized NIR spectroscopy as a quality control tool for small-scale, pharmacy preparations. Due to its non-destructive nature, every dosage unit can be tested thus affording positive impact on patient safety. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
[41]   Recent Advances in the Application of Near-Infrared Spectroscopy in Quality Detection of Sweet Potato [J].
He H. ;
Wang J. ;
Liu H. ;
Chen Y. ;
Wang Y. ;
Ou X. ;
Zhang M. ;
Liu H. ;
Guo J. .
Shipin Kexue/Food Science, 2023, 44 (21) :341-358
[42]   Short-wave near infrared spectroscopy for the quality control of milk [J].
Asaduzzaman, Mohammad ;
Kerschbaumer, Martin ;
Bodner, Martina ;
Haman, Nabil ;
Scampicchio, Matteo .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2020, 28 (01) :3-9
[43]   IN-LINE QUALITY CONTROL OF POLYMER NANOCOMPOSITES USING NEAR-INFRARED SPECTROSCOPY [J].
Laske, Stephan ;
Witschnig, Andreas ;
Kracalik, Milan ;
Feuchter, Michael ;
Pinter, Gerald ;
Maier, Gunther ;
Langecker, Gunter Rudiger ;
Holzer, Clemens .
NANOCON 2009, CONFERENCE PROCEEDINGS, 2009, :120-+
[44]   Tablet identification using near-infrared spectroscopy (NIRS) for pharmaceutical quality control [J].
Alvarenga, L. ;
Ferreira, D. ;
Altekruse, D. ;
Menezes, J. C. ;
Lochmann, D. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (01) :62-69
[45]   Detection of Organic Acids and pH of Fruit Vinegars Using Near-Infrared Spectroscopy and Multivariate Calibration [J].
Liu, Fei ;
He, Yong ;
Wang, Li ;
Sun, Guangming .
FOOD AND BIOPROCESS TECHNOLOGY, 2011, 4 (08) :1331-1340
[46]   Near-Infrared Spectroscopy with Machine Learning for Classifying and Quantifying Nutmeg Adulteration [J].
Sitorus, Agustami ;
Pambudi, Suluh ;
Boodnon, Wutthiphong ;
Lapcharoensuk, Ravipat .
ANALYTICAL LETTERS, 2024, 57 (02) :285-306
[47]   Qualitative and Quantitative Detection of Acacia Honey Adulteration with Glucose Syrup Using Near-Infrared Spectroscopy [J].
Benkovic, Maja ;
Jurina, Tamara ;
Longin, Lucija ;
Grbes, Franjo ;
Valinger, Davor ;
Tusek, Ana Jurinjak ;
Kljusuric, Jasenka Gajdos .
SEPARATIONS, 2022, 9 (10)
[48]   Comparison and application of near-infrared (NIR) and mid-infrared (MIR) spectroscopy for determination of quality parameters in soybean samples [J].
Ferreira, D. S. ;
Galao, O. F. ;
Pallone, J. A. L. ;
Poppi, R. J. .
FOOD CONTROL, 2014, 35 (01) :227-232
[49]   Application of Near-Infrared Spectroscopy to statistical control in freeze-drying processes [J].
Bobba, Serena ;
Zinfollino, Nunzio ;
Fissore, Davide .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2021, 168 :26-37
[50]   Comparative analysis of rapid quality evaluation of Salvia miltiorrhiza (Danshen) with Fourier transform near-infrared spectrometer and portable near-infrared spectrometer [J].
Sun, Yue ;
Yuan, Meng ;
Liu, Xiaoyan ;
Su, Mei ;
Wang, Linlin ;
Zeng, Yingzi ;
Zang, Hengchang ;
Nie, Lei .
MICROCHEMICAL JOURNAL, 2020, 159