Feasibility study on a simple method of retrospective neutron dosimetry for reactor internals and reactor vessel

被引:0
|
作者
Hayashi, Katsumi [1 ]
Tayanma, Ryuuichi [1 ]
Watanabe, Yoshio [1 ]
Nakamura, Tomomi [1 ]
Kubota, Isamu
Hayashi, Haruhisa
Yamasaki, Tadashi
Yuya, Hideki
机构
[1] Hitachi Ltd, Ibaraki 3178511, Japan
来源
REACTOR DOSIMETRY: 12TH INTERNATIONAL SYMPOSIUM | 2008年 / 1490卷
关键词
retrospective closimetry; nondestructive; reactor internals; reactor vessel; Hgl(2); MCNP;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Nondestructive and simple retrospective dosimetry method was developed. Mercuric iodide or cadmium zinc telluride detector was used as a detector to measure Mn-54, Co-58, and Co-60 that were created in reactor internals and vessels. Detector is surrounded by tungsten collimator which shield background gamma rays and detect gamma rays from desired measuring point. Photopeak count rate of this detector were calculated using the MCNP-4C Code. This response was calculated for each reactor internal geometry that was irradiated by unit neutron flux which energy spectrum was calculated by the TORT code. Neutron fluence is calculated using precalculated response, measuring time, decay time and reactor power history. We can also get Displacement per Atom (DPA), hydrogen and helium production simultaneously using neutron spectrum precalculated in reactor vessel. Because the time and cost of this method are much less than the sampling method, we can measure at many positions and even get a contour map.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 19 条
  • [1] Lifetime analysis of wwer reactor pressure vessel internals concerning material degradation
    Ju. Dudra
    Sz. Szávai
    Strength of Materials, 2010, 42 : 51 - 57
  • [2] LIFETIME ANALYSIS OF WWER REACTOR PRESSURE VESSEL INTERNALS CONCERNING MATERIAL DEGRADATION
    Dudra, Ju.
    Szavai, Sz.
    STRENGTH OF MATERIALS, 2010, 42 (01) : 51 - 57
  • [3] Computational Methods and Representative Cases for Fluid–Structure Interaction in Nuclear Reactor Vessel and Internals
    Pascal Veber
    Fredrik Tornberg
    Afaque Shams
    Osman K. Siddiqui
    Arabian Journal for Science and Engineering, 2025, 50 (5) : 3591 - 3615
  • [4] Reliability Evaluation Method of Bolts of Reactor Internals in High-neutron-fluence-rate Region Based on XGBoost
    Wang W.
    Wan A.
    Deng C.
    Gong Z.
    Zhang H.
    Ye Y.
    Wang P.
    Liu C.
    Li Y.
    Hedongli Gongcheng/Nuclear Power Engineering, 2022, 43 (05): : 154 - 162
  • [5] Numerical study on fluid flow by hydrodynamic loads in reactor internals
    Kim, Da-Hye
    Chang, Yoon-Suk
    Jhung, Myung-Jo
    STRUCTURAL ENGINEERING AND MECHANICS, 2014, 51 (06) : 1005 - 1016
  • [6] Computational Methods and Representative Cases for Fluid-Structure Interaction in Nuclear Reactor Vessel and Internals
    Veber, Pascal
    Tornberg, Fredrik
    Shams, Afaque
    Siddiqui, Osman K.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024,
  • [7] Computational Methods and Representative Cases for Fluid-Structure Interaction in Nuclear Reactor Vessel and Internals
    Veber, Pascal
    Tornberg, Fredrik
    Shams, Afaque
    Siddiqui, Osman K.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2025, 50 (05) : 3591 - 3615
  • [8] Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry
    Rouihem, F.
    Dridi, W.
    Daoudi, M.
    Blaise, P.
    Geslot, B.
    Farah, K.
    Mustapha, B.
    Hosni, F.
    ANNALS OF NUCLEAR ENERGY, 2020, 142 (142)
  • [9] Reactor dosimetry study of the Rhode Island Nuclear Science Center
    Holden, N. E.
    Reciniello, R. N.
    Hu, J. -P
    Leith, J.
    Tehan, T. N.
    REACTOR DOSIMETRY: 12TH INTERNATIONAL SYMPOSIUM, 2008, 1490 : 26 - 33
  • [10] Conceptual study of subcritical assembly with neutron generator for reactor physics experiments and neutron utilization
    Nakagomi, Hiroshi
    Yoshioka, Kenichi
    Sugita, Tsukasa
    Miyadera, Haruo
    ANNALS OF NUCLEAR ENERGY, 2025, 212