Functional CT of squamous cell carcinoma in the head and neck: repeatability of tumor and muscle quantitative measurements, inter- and intra-observer agreement

被引:21
作者
Bisdas, Sotirios [1 ]
Surlan-Popovic, Katarina [2 ]
Didanovic, Vojko [3 ]
Vogl, Thomas J. [1 ]
机构
[1] Johann Wolfgang Goethe Univ Hosp, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Ctr Ljubljana, Dept Clin Radiol, Ljubljana, Slovenia
[3] Clin Ctr Ljubljana, Dept Head Neck & Maxillofacial Surg, Ljubljana, Slovenia
关键词
functional CT; squamous cell carcinoma; repeatability; inter- and intra-observer agreement;
D O I
10.1007/s00330-008-0990-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our purpose was to determine the repeatability of squamous cell cancer in head and neck (SCCHN) and muscle tissue vascularity measurements as well as the inter- and intra- observer agreement using dynamic contrast-enhanced (DCE) multi-detector CT (MDCT). Twelve patients with histologically proven SCCHN were twice examined within 46 h. Measurement error and repeatability were assessed for each of the four functional parameters using the Bland-Altman plots. Two independent observers recorded the vascularity values of the tumor tissue; inter- and intra- observer agreement was assessed using the Bland-Altman plot analysis and intraclass correlation coefficients. For the tumor, the mean difference (95% limits of agreement) was 0.40 ml/min/100 g tissue (-6.80, 9.60); 0.01 (-0.96, 0.97) ml/100 g tissue; 0.20 (-1.80, 2.30) s; and 0.40 (-2.00, 2.80) ml/min/100 g tissue for BF, BV, MTT, and PS, respectively. For the muscle, the mean difference (95% limits of agreement) was -0.18 (-1.70, 1.35), 0.04 (-1.17, 1.35), -0.10 (-5.80, 5.60), and -0.10 (-2.20, 2.00), respectively. Measurement changes of at least +/- 8%, 30%, 36%, and 13% were found to be significant for BF, BV, MTT, and PS, respectively. There was better intra-than inter-observer agreement.
引用
收藏
页码:2241 / 2250
页数:10
相关论文
共 24 条
  • [1] Quantitative measurements of perfusion and permeability of oropharyngeal and oral cavity cancer, recurrent disease, and associated lymph nodes using first-pass contrast-enhanced computed tomography studies
    Bisdas, Sotirios
    Baghi, Mehran
    Smolarz, Agnieszka
    Pihno, Nicole Chambron
    Lehnert, Thomas
    Knecht, Rainald
    Mack, Martin G.
    Vogl, Thomas J.
    Tuerkay, Sehib
    Koh, Tong San
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (03) : 172 - 179
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] LIVER PERFUSION STUDIED WITH ULTRAFAST CT
    BLOMLEY, MJK
    COULDEN, R
    DAWSON, P
    KORMANO, M
    DONLAN, P
    BUFKIN, C
    LIPTON, MJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) : 424 - 433
  • [4] Cenic A, 1999, AM J NEURORADIOL, V20, P63
  • [5] Cenic A, 2000, AM J NEURORADIOL, V21, P462
  • [6] Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
    Erasmus, JJ
    Gladish, GW
    Broemeling, L
    Sabloff, BS
    Truong, MT
    Herbst, RS
    Munden, RF
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (13) : 2574 - 2582
  • [7] Fiorella D, 2004, AM J NEURORADIOL, V25, P97
  • [8] Computed tomography perfusion of squamous cell carcinoma of the upper aerodigestive tract -: Initial results
    Gandhi, D
    Hoeffner, EG
    Carlos, RC
    Case, I
    Mukherji, SK
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (05) : 687 - 693
  • [9] Quantitative assessment of colorectal cancer perfusion using MDCT: inter- and intraobserver agreement
    Goh, V
    Halligan, S
    Hugill, JA
    Bassett, P
    Bartram, CI
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) : 225 - 231
  • [10] Quantitative assessment of tissue perfusion using MDCT: Comparison of colorectal cancer and skeletal muscle measurement reproducibility
    Goh, Vicky
    Halligan, Steve
    Hugill, Jo-Ann
    Bartram, Clive I.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) : 164 - 169