How reliable are Hounsfield-unit measurements in forensic radiology?

被引:33
|
作者
Ruder, Thomas D. [1 ]
Thali, Yannick [1 ]
Schindera, Sebastian T. [2 ]
Dalla Torre, Simon A. [3 ]
Zech, Wolf-Dieter [4 ]
Thali, Michael J. [1 ,4 ]
Ross, Steffen [1 ]
Hatch, Gary M. [1 ]
机构
[1] Univ Bern, Inst Forens Med, Ctr Forens Imaging & Virtopsy, CH-3012 Bern, Switzerland
[2] Univ Hosp Bern, Inselspital, Inst Radiol, CH-3010 Bern, Switzerland
[3] Swiss Agcy Therapeut Prod, Swissmed, CH-3000 Bern 9, Switzerland
[4] Univ Bern, Inst Forens Med, Dept Forens Pathol, CH-3012 Bern, Switzerland
关键词
Forensic radiology; Computed tomography; HU measurements; Object identification; Reliability; Reference model; MULTISLICE COMPUTED-TOMOGRAPHY; BONE-MINERAL MEASUREMENTS; QUALITY-CONTROL; PHANTOM; CT; STANDARDIZATION; IDENTIFICATION; SPINE; QCT; DXA;
D O I
10.1016/j.forsciint.2012.03.004
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Objective: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. Materials and methods: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. Results: HU values did not change significantly as a function of ROI-shape or -size (p > 0.05). Intra-reader reliability reached ICC values >0.929 (p < 0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p < 0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p < 0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p < 0.05). Conclusion: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 21 条
  • [1] The Forensic Reference Phantom-a new tool for quality assurance of attenuation measurements in forensic radiology
    Ruder, Thomas D.
    Hatch, Gary M.
    Ebert, Lars
    Thali, Yannick
    Allmendinger, Thomas
    Schindera, Sebastian T.
    Torre, Simon A. Dalla
    Gascho, Dominic
    Thali, Michael J.
    Ampanozi, Garyfalia
    JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2013, 1 (02) : 51 - 55
  • [2] Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful?
    Shemesh, Shay
    Luckman, Judith
    Marom, Tal
    Kraus, Oded
    Tamir, Sharon Ovnat
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2022, 26 (03) : E414 - E421
  • [3] How Reliable Are Forensic Evaluations of Legal Sanity?
    Gowensmith, W. Neil
    Murrie, Daniel C.
    Boccaccini, Marcus T.
    LAW AND HUMAN BEHAVIOR, 2013, 37 (02) : 98 - 106
  • [4] How reliable are texture measurements?
    Robins, Marthony
    Solomon, Justin
    Hoye, Jocelyn
    Abadi, Ehsan
    Marin, Daniele
    Samei, Ehsan
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [5] Inter-Rater Reliability and Correlation of L1 Hounsfield Unit Measurements with DXA Scores
    Mooney, James
    Morgan, Sarah
    Brockington, David
    Rehder, Dirk
    Rothenberg, Steven
    Omar, Nidal
    MacLennan, Paul
    Chambers, M. R.
    JOURNAL OF CLINICAL DENSITOMETRY, 2022, 25 (04) : 668 - 673
  • [6] HOW RELIABLE ARE OCCIPITAL ASYMMETRY MEASUREMENTS
    CHU, CC
    TRANEL, D
    DAMASIO, H
    NEUROPSYCHOLOGIA, 1994, 32 (12) : 1503 - +
  • [7] Preliminary X-ray CT investigation to link Hounsfield unit measurements with the International System of Units (SI)
    Levine, Zachary H.
    Peskin, Adele P.
    Holmgren, Andrew D.
    Garboczi, Edward J.
    PLOS ONE, 2018, 13 (12):
  • [8] How reliable are the risk estimates for X-ray examinations in forensic age estimations? A safety update
    Ramsthaler, F.
    Proschek, P.
    Betz, W.
    Verhoff, M. A.
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2009, 123 (03) : 199 - 204
  • [9] CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion
    Yao, Yu-Cheng
    Chao, Hsien
    Kao, Kun-Yu
    Lin, Hsi-Hsien
    Wang, Shih-Tien
    Chang, Ming-Chau
    Liu, Chien-Lin
    Chou, Po-Hsin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [10] Relation of computerized tomography Hounsfield unit measurements and internal components of fresh chestnuts (Castanea spp.)
    Donis-Gonzalez, Irwin R.
    Guyer, Daniel E.
    Pease, Anthony
    Fulbright, Dennis W.
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2012, 64 (01) : 74 - 82