A 3-D ULTRASOUND IMAGING ROBOTIC SYSTEM TO DETECT AND QUANTIFY LOWER LIMB ARTERIAL STENOSES: IN VIVO FEASIBILITY

被引:13
作者
Janvier, Marie-Ange [1 ,2 ]
Merouche, Samir [1 ,2 ]
Allard, Louise [1 ]
Soulez, Gilles [2 ,3 ,4 ]
Cloutier, Guy [1 ,2 ,4 ]
机构
[1] Univ Montreal Hosp CRCHUM, Res Ctr, Lab Biorheol & Med Ultrason, Montreal, PQ, Canada
[2] Univ Montreal, Inst Biomed Engn, Montreal, PQ, Canada
[3] Univ Montreal Hosp CHUM, Dept Radiol, Montreal, PQ, Canada
[4] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ, Canada
基金
加拿大健康研究院;
关键词
3-D ultrasound imaging system; 3-D reconstruction; Robotics; Vascular phantom; Lower limb arterial disease; Computerized tomography angiography; Arterial stenosis; 3D ULTRASOUND; 3-DIMENSIONAL ULTRASOUND; CAROTID-ARTERY; FEMORAL-ARTERY; RECONSTRUCTION; VOLUME; QUANTIFICATION; BIFURCATION; GEOMETRY; GRAFTS;
D O I
10.1016/j.ultrasmedbio.2013.08.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The degree of stenosis is the most common criterion used to assess the severity of lower limb peripheral arterial disease. Two-dimensional ultrasound (US) imaging is the first-line diagnostic method for investigating lesions, but it cannot render a 3-D map of the entire lower limb vascular tree required for therapy planning. We propose a prototype 3-D US imaging robotic system that can potentially reconstruct arteries from the iliac in the lower abdomen down to the popliteal behind the knee. A realistic multi-modal vascular phantom was first conceptualized to evaluate the system's performance. Geometric accuracies were assessed in surface reconstruction and cross-sectional area in comparison to computed tomography angiography (CTA). A mean surface map error of 0.55 mm was recorded for 3-D US vessel representations, and cross-sectional lumen areas were congruent with CTA geometry. In the phantom study, stenotic lesions were properly localized and severe stenoses up to 98.3% were evaluated with -3.6 to 11.8% errors. The feasibility of the in vivo system in reconstructing the normal femoral artery segment of a volunteer and detecting stenoses on a femoral segment of a patient was also investigated and compared with that of CTA. Together, these results encourage future developments to increase the robot's potential to adequately represent lower limb vessels and clinically evaluate stenotic lesions for therapy planning and recurrent non-invasive and non-ionizing follow-up examinations. (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:232 / 243
页数:12
相关论文
共 37 条
[1]   Image-guided control of a robot for medical ultrasound [J].
Abolmaesumi, P ;
Salcudean, SE ;
Zhu, WH ;
Sirouspour, MR ;
DiMaio, SP .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 2002, 18 (01) :11-23
[2]   Multimodality vascular imaging phantoms: A new material for the fabrication of realistic 3D vessel geometries [J].
Allard, Louise ;
Soulez, Gilles ;
Chayer, Boris ;
Treyve, Francois ;
Qin, Zhao ;
Cloutier, Guy .
MEDICAL PHYSICS, 2009, 36 (08) :3758-3763
[3]   Volumetric assessment of carotid artery bifurcation using freehand-acquired, compound 3D ultrasound [J].
Allott, CP ;
Barry, CD ;
Pickford, R ;
Waterton, JC .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (855) :289-292
[4]   Echographic examination in isolated sites controlled from an expert center using a 2-D echograph guided by a teleoperated robotic arm [J].
Arbeille, P ;
Poisson, G ;
Vieyres, P ;
Ayoub, J ;
Porcher, M ;
Boulay, JL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (07) :993-1000
[5]   Force feedback controller based on fuzzy-rules emulated networks and Hertzian contact with ultrasound [J].
Armendariz, J. ;
Treesatayapun, C. ;
Baltazar, A. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 27 :534-550
[6]   Reconstruction and quantification of the carotid artery bifurcation from 3D ultrasound images [J].
Barratt, DC ;
Ariff, BB ;
Humphries, KN ;
Thom, SAM ;
Hughes, AD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :567-583
[7]   Three-dimensional freehand ultrasound: Image reconstruction and volume analysis [J].
Barry, CD ;
Allott, CP ;
John, NW ;
Mellor, PM ;
Arundel, PA ;
Thomson, DS ;
Waterton, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1209-1224
[8]   Mechanically assisted 3D ultrasound guided prostate biopsy system [J].
Bax, Jeffrey ;
Cool, Derek ;
Gardi, Lori ;
Knight, Kerry ;
Smith, David ;
Montreuil, Jacques ;
Sherebrin, Shi ;
Romagnoli, Cesare ;
Fenster, Aaron .
MEDICAL PHYSICS, 2008, 35 (12) :5397-5410
[9]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[10]   Systematic distortions in magnetic position digitizers [J].
Birkfellner, W ;
Watzinger, F ;
Wanschitz, F ;
Enislidis, G ;
Kollmann, C ;
Rafolt, D ;
Nowotny, R .
MEDICAL PHYSICS, 1998, 25 (11) :2242-2248