Factors Associated With Trunnionosis in the Metal-on-Metal Pinnacle Hip

被引:36
作者
Hothi, Harry S. [1 ,2 ]
Eskelinen, Antti P. [3 ]
Berber, Reshid [1 ,2 ]
Lainiala, Olli S. [3 ]
Moilanen, Teemu P. S. [3 ]
Skinner, John A. [1 ,2 ]
Hart, Alister J. [1 ,2 ]
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore, Middx, England
[2] Royal Natl Orthopaed Hosp, Stanmore, Middx, England
[3] Coxa Hosp Joint Replacement, Tampere, Finland
关键词
taper; material loss; corrosion; retrieval; metal-on-metal; SURFACE-TOPOGRAPHY; TAPER JUNCTION; CORROSION; REPLACEMENT; PROSTHESES; RETRIEVAL; WEAR;
D O I
10.1016/j.arth.2016.06.038
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Trunnionosis of the tapered head-stem junction of total hip arthroplasties, either through corrosion or mechanical wear, has been implicated in early implant failure. Retrieval analysis of large numbers of failed implants can help us better understand the factors that influence damage at this interface. Methods: In this study, we examined 120 retrieved total hip arthroplasties of one bearing design, the 36-mm diameter metal-on-metal, DePuy Pinnacle, that had been paired with 3 different stems. We measured material loss of the bearing and head-trunnion taper surfaces and collected clinical and component data for each case. We then used multiple linear regression analysis to determine which factors influenced the rate of taper material loss. Results: We found 4 significant variables: (1) longer time to revision (P = .004), (2) the use of a 12/14 taper for the head-trunnion junction (P < .001), (3) decreased bearing surface wear (P = .003), and (4) vertical femoral offset (P = .05). These together explained 29% of the variability in taper material loss. Conclusion: Our most important finding is the effect of trunnion design. Of the 3 types studied, we found that S-ROM design was the most successful at minimizing trunnionosis. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:286 / 290
页数:5
相关论文
共 50 条
  • [31] Retrieval Analysis of Large-Head Modular Metal-on-Metal Hip Replacements of a Single Design
    Gascoyne, Trevor C.
    Turgeon, Thomas R.
    Burnell, Colin D.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (06) : 1945 - 1952
  • [32] Metal-on-Metal Local Tissue Reaction Is Associated With Corrosion of the Head Taper Junction
    Fricka, Kevin B.
    Ho, Henry
    Peace, William J.
    Engh, Charles A., Jr.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 26 - 31
  • [33] Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty
    Lanting, Brent A.
    Teeter, Matthew G.
    Howard, James L.
    MacDonald, Steven J.
    Van Citters, Douglas W.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08) : 2574 - 2579
  • [34] Cobalt and Chromium Ion Release After Large-Diameter Metal-on-Metal Total Hip Arthroplasty
    Hasegawa, Masahiro
    Yoshida, Kakunoshin
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 990 - 996
  • [35] The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations
    Hjorth, Mette Holm
    Mechlenburg, Inger
    Soballe, Kjeld
    Roemer, Lone
    Stilling, Maiken
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2019, 18 : 74 - 83
  • [36] Does modularity of metal-on-metal hip implants increase cobalt: chromium ratio?
    Ilo, Kevin C.
    Aboelmagd, Karim
    Hothi, Harry S.
    Asaad, Asaad
    Skinner, John A.
    Hart, Alister J.
    HIP INTERNATIONAL, 2021, 31 (01) : 109 - 114
  • [37] Association Between Pseudotumor Formation and Patient Factors in Metal-on-Metal Total Hip Arthroplasty Population
    Kleeman, Lindsay T.
    Goltz, Daniel
    Seyler, Thorsten M.
    Mammarappallil, Joseph G.
    Attarian, David E.
    Wellman, Samuel S.
    Bolognesi, Michael P.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07) : S259 - S264
  • [38] Lessons learnt from metal-on-metal hip arthroplasties will lead to safer innovation for all medical devices
    Hart, Alister J.
    Sabah, Shiraz A.
    Henckel, Johann
    Lloyd, Gwynneth
    Skinner, John A.
    HIP INTERNATIONAL, 2015, 25 (04) : 347 - 354
  • [39] Electrochemical instrumentation of a hip simulator: a new tool for assessing the role of corrosion in metal-on-metal hip joints
    Yan, Y.
    Neville, A.
    Dowson, D.
    Williams, S.
    Fisher, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H11) : 1267 - 1273
  • [40] Metal-on-Metal Hip Resurfacing
    Quesada, Mario J.
    Marker, David R.
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07) : 69 - 73