Factors Associated With Trunnionosis in the Metal-on-Metal Pinnacle Hip

被引:36
作者
Hothi, Harry S. [1 ,2 ]
Eskelinen, Antti P. [3 ]
Berber, Reshid [1 ,2 ]
Lainiala, Olli S. [3 ]
Moilanen, Teemu P. S. [3 ]
Skinner, John A. [1 ,2 ]
Hart, Alister J. [1 ,2 ]
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore, Middx, England
[2] Royal Natl Orthopaed Hosp, Stanmore, Middx, England
[3] Coxa Hosp Joint Replacement, Tampere, Finland
关键词
taper; material loss; corrosion; retrieval; metal-on-metal; SURFACE-TOPOGRAPHY; TAPER JUNCTION; CORROSION; REPLACEMENT; PROSTHESES; RETRIEVAL; WEAR;
D O I
10.1016/j.arth.2016.06.038
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Trunnionosis of the tapered head-stem junction of total hip arthroplasties, either through corrosion or mechanical wear, has been implicated in early implant failure. Retrieval analysis of large numbers of failed implants can help us better understand the factors that influence damage at this interface. Methods: In this study, we examined 120 retrieved total hip arthroplasties of one bearing design, the 36-mm diameter metal-on-metal, DePuy Pinnacle, that had been paired with 3 different stems. We measured material loss of the bearing and head-trunnion taper surfaces and collected clinical and component data for each case. We then used multiple linear regression analysis to determine which factors influenced the rate of taper material loss. Results: We found 4 significant variables: (1) longer time to revision (P = .004), (2) the use of a 12/14 taper for the head-trunnion junction (P < .001), (3) decreased bearing surface wear (P = .003), and (4) vertical femoral offset (P = .05). These together explained 29% of the variability in taper material loss. Conclusion: Our most important finding is the effect of trunnion design. Of the 3 types studied, we found that S-ROM design was the most successful at minimizing trunnionosis. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:286 / 290
页数:5
相关论文
共 50 条
  • [21] Metal-on-metal total hip arthroplasty is not associated with cardiac disease
    Goodnough, L. H.
    Bala, A.
    Huddleston, J. I., III
    Goodman, S. B.
    Maloney, W. J.
    Amanatullah, D. F.
    BONE & JOINT JOURNAL, 2018, 100B (01) : 28 - 32
  • [22] Surface Characterization of Retrieved Metal-on-Metal Total Hip Implants from Patients with Adverse Reaction to Metal Debris
    Burbano, Maria
    Russell, Robert
    Huo, Michael
    Welch, Robert
    Roy, Diana
    Rodrigues, Danieli C.
    MATERIALS, 2014, 7 (03): : 1866 - 1879
  • [23] Factors associated with symptomatic pseudotumors following metal-on-metal total hip arthroplasty
    Masahiro Hasegawa
    Yohei Naito
    Toshio Yamaguchi
    Shinichi Miyazaki
    Hiroki Wakabayashi
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 17
  • [24] Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty - a systematic review
    Sorensen, Sofie-Amalie L. Ras
    Jorgensen, Henrik L.
    Sporing, Sune L.
    Lauritzen, Jes B.
    HIP INTERNATIONAL, 2016, 26 (06) : 515 - 521
  • [25] Taper Design Affects Failure of Large-head Metal-on-metal Total Hip Replacements
    Nassif, Nader A.
    Nawabi, Danyal H.
    Stoner, Kirsten
    Elpers, Marcella
    Wright, Timothy
    Padgett, Douglas E.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (02) : 564 - 571
  • [26] Origins of material loss in highly worn acetabular cups of metal-on-metal total hip replacements
    Lu, Zhen
    Ebramzadeh, Edward
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (01) : 143 - 150
  • [27] Material Loss at the Taper Junction of Retrieved Large Head Metal-on-Metal Total Hip Replacements
    Matthies, Ashley K.
    Racasan, Radu
    Bills, Paul
    Blunt, Liam
    Cro, Suzie
    Panagiotidou, Anna
    Blunn, Gordon
    Skinner, John
    Hart, Alister J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (11) : 1677 - 1685
  • [28] Clinical significance of corrosion of cemented femoral stems in metal-on-metal hips: a retrieval study
    Hothi, Harry S.
    Berber, Reshid
    Panagiotopoulos, Andreas C.
    Whittaker, Robert K.
    Rhead, Camilla
    Skinner, John A.
    Hart, Alister J.
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (11) : 2247 - 2254
  • [29] Management Guidelines for Metal-on-metal Hip Resurfacing Arthroplasty: A Strategy on Followup
    Nakano, Naoki
    Volpin, Andrea
    Bartlett, Jonathan
    Khanduja, Vikas
    INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (04) : 414 - 420
  • [30] Corrosion on the Acetabular Liner Taper from Retrieved Modular Metal-on-Metal Total Hip Replacements
    Gascoyne, Trevor C.
    Dyrkacz, Richard M.
    Turgeon, Thomas R.
    Burnell, Colin D.
    Wyss, Urs P.
    Brandt, Jan-M.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (10) : 2049 - 2052