Study on the performance of different types of three-dimensional chromatographic systems

被引:27
作者
Davydova, Ekaterina [1 ]
Schoenmakers, Peter J. [1 ]
Vivo-Truyols, Gabriel [1 ]
机构
[1] Univ Amsterdam, Analyt Chem Grp, Vant Hoff Inst Mol Sci, NL-1090 GD Amsterdam, Netherlands
关键词
Three-dimensional liquid chromatography; Spatial chromatography; LC x LC x LC; Peak capacity; 2-DIMENSIONAL LIQUID-CHROMATOGRAPHY; PARETO-OPTIMALITY; PEAK-CAPACITY; SEPARATION; COLUMN;
D O I
10.1016/j.chroma.2012.11.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The maximum achievable performance of possible types of three-dimensional chromatographic systems (LC x LC x LC) has been investigated. The Pareto-optimization approach was applied to establish a trade-off between three main objectives (total peak capacity, analysis time and dilution of the sample) and Pareto-front values were obtained. The performances of (LC)-L-x x (LC)-L-x x (LC)-L-x (three-dimensional separation in space), (LC)-L-t x (LC)-L-t x (LC)-L-t (three-dimensional separation in time) and the hybrid (LC)-L-x x (LC)-L-x x (LC)-L-t system were compared mutually and with two-dimensional chromatographic systems. It was found that (LC)-L-x x (LC)-L-x x (LC)-L-x performs best in terms of maximum achievable peak capacity in shortest analysis time. Based on current thin-layer-chromatography performance it should be possible to obtain a peak capacity of 50,000 within 20 min. If contemporary column-packing standards can be upheld the achievable limit is approximately 50% higher. However, in an (LC)-L-x x (LC)-L-x x (LC)-L-x chromatographic system analytes remain in the separation domain after the analysis, which complicates the detection. Use of an (LC)-L-x x (LC)-L-x x (LC)-L-t system with elution in the last dimension alleviates the detection problem. The maximum achievable peak capacity in the same analysis time is lower for (LC)-L-x x (LC)-L-x x (LC)-L-t than for (LC)-L-x x (LC)-L-x x (LC)-L-x. Using the same (reasonable) length of the separation domain (e.g. a cube 200 x 200 x 200 mm) for both systems, it is possible to achieve peak capacities of 78,000 for (LC)-L-x x (LC)-L-x x (LC)-L-t operated in the gradient mode, which is twice higher than for an (LC)-L-x x (LC)-L-x x (LC)-L-x system. A three-dimensional (three-column) time-based (LC)-L-t x (LC)-L-t x (LC)-L-t system does not greatly improve the performance of (LC)-L-t x (LC)-L-t in terms of (maximum) peak capacity and (minimum) analysis time. Dilution factors in (LC)-L-t x (LC)-L-t x (LC)-L-t are very high. Decreasing the dilution has a detrimental influence on the peak capacity. The trade-off between these objectives is of crucial importance. The influence of several parameters (length of the separation domain, particle size, etc.) on the performance of chromatographic systems was investigated, optimal ranges were found. (C) 2012 Published by Elsevier B.V.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [41] Retention Study of Flavonoids Under Different Chromatographic Modes
    Sentkowska, Aleksandra
    Biesaga, Magdalena
    Pyrzynska, Krystyna
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (04) : 516 - 522
  • [42] Three-dimensional simulation of wind tunnel diffuser to study the effects of different divergence angles on speed uniform distribution, pressure in outlet, and eddy flows formation in the corners
    Li, Zhixiong
    Moradi, Iman
    Nguyen, Quyen
    Karimipour, Arash
    Afrand, Masoud
    Tlili, Iskander
    Incecik, Atilla
    PHYSICS OF FLUIDS, 2020, 32 (05)
  • [43] Application of three-dimensional printing technology in environmental analysis: A review
    Zhang, Junpeng
    Wang, Dingyi
    Li, Yingying
    Liu, Lihong
    Liang, Yong
    He, Bin
    Hu, Ligang
    Jiang, Guibin
    ANALYTICA CHIMICA ACTA, 2023, 1281
  • [44] Visualizing three-dimensional effects of synthetic jet flow control
    Machado, Adnan
    Xu, Kecheng
    Sullivan, Pierre E.
    JOURNAL OF VISUALIZATION, 2024, 27 (05) : 765 - 774
  • [45] Coherent structures and dominant frequencies in a turbulent three-dimensional diffuser
    Malm, Johan
    Schlatter, Philipp
    Henningson, Dan S.
    JOURNAL OF FLUID MECHANICS, 2012, 699 : 320 - 351
  • [46] Three-dimensional diamagnetic particle deflection in ferrofluid microchannel flows
    Liang, Litao
    Zhu, Junjie
    Xuan, Xiangchun
    BIOMICROFLUIDICS, 2011, 5 (03):
  • [47] Three-Dimensional Polymer Nanofiber Structures for Liquid Contamination Adsorption
    Liu, Yunjie
    Li, Yanting
    Liu, Yonglei
    Gong, Pengjian
    Niu, Yanhua
    Park, Chul B.
    Li, Guangxian
    ACS APPLIED NANO MATERIALS, 2022, 5 (04) : 5640 - 5651
  • [48] Carborane-Based Three-Dimensional Covalent Organic Frameworks
    Xu, Xiaoyi
    Cui, Qirui
    Chen, Hongzheng
    Huang, Ning
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2023, 145 (44) : 24202 - 24209
  • [49] Three-dimensional microtissues as an in vitro model for personalized radiation therapy
    Qiu, Yuting
    Ning, Dandan
    Zhang, Peipei
    Curly, Stephanie
    Qiao, Yong
    Ma, Liyuan
    Su, Ming
    ANALYST, 2017, 142 (19) : 3605 - 3612
  • [50] High sensitivity three-dimensional insulator-based dielectrophoresis
    Braff, William A.
    Pignier, Alexandre
    Buie, Cullen R.
    LAB ON A CHIP, 2012, 12 (07) : 1327 - 1331