Study on the performance of different types of three-dimensional chromatographic systems

被引:27
|
作者
Davydova, Ekaterina [1 ]
Schoenmakers, Peter J. [1 ]
Vivo-Truyols, Gabriel [1 ]
机构
[1] Univ Amsterdam, Analyt Chem Grp, Vant Hoff Inst Mol Sci, NL-1090 GD Amsterdam, Netherlands
关键词
Three-dimensional liquid chromatography; Spatial chromatography; LC x LC x LC; Peak capacity; 2-DIMENSIONAL LIQUID-CHROMATOGRAPHY; PARETO-OPTIMALITY; PEAK-CAPACITY; SEPARATION; COLUMN;
D O I
10.1016/j.chroma.2012.11.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The maximum achievable performance of possible types of three-dimensional chromatographic systems (LC x LC x LC) has been investigated. The Pareto-optimization approach was applied to establish a trade-off between three main objectives (total peak capacity, analysis time and dilution of the sample) and Pareto-front values were obtained. The performances of (LC)-L-x x (LC)-L-x x (LC)-L-x (three-dimensional separation in space), (LC)-L-t x (LC)-L-t x (LC)-L-t (three-dimensional separation in time) and the hybrid (LC)-L-x x (LC)-L-x x (LC)-L-t system were compared mutually and with two-dimensional chromatographic systems. It was found that (LC)-L-x x (LC)-L-x x (LC)-L-x performs best in terms of maximum achievable peak capacity in shortest analysis time. Based on current thin-layer-chromatography performance it should be possible to obtain a peak capacity of 50,000 within 20 min. If contemporary column-packing standards can be upheld the achievable limit is approximately 50% higher. However, in an (LC)-L-x x (LC)-L-x x (LC)-L-x chromatographic system analytes remain in the separation domain after the analysis, which complicates the detection. Use of an (LC)-L-x x (LC)-L-x x (LC)-L-t system with elution in the last dimension alleviates the detection problem. The maximum achievable peak capacity in the same analysis time is lower for (LC)-L-x x (LC)-L-x x (LC)-L-t than for (LC)-L-x x (LC)-L-x x (LC)-L-x. Using the same (reasonable) length of the separation domain (e.g. a cube 200 x 200 x 200 mm) for both systems, it is possible to achieve peak capacities of 78,000 for (LC)-L-x x (LC)-L-x x (LC)-L-t operated in the gradient mode, which is twice higher than for an (LC)-L-x x (LC)-L-x x (LC)-L-x system. A three-dimensional (three-column) time-based (LC)-L-t x (LC)-L-t x (LC)-L-t system does not greatly improve the performance of (LC)-L-t x (LC)-L-t in terms of (maximum) peak capacity and (minimum) analysis time. Dilution factors in (LC)-L-t x (LC)-L-t x (LC)-L-t are very high. Decreasing the dilution has a detrimental influence on the peak capacity. The trade-off between these objectives is of crucial importance. The influence of several parameters (length of the separation domain, particle size, etc.) on the performance of chromatographic systems was investigated, optimal ranges were found. (C) 2012 Published by Elsevier B.V.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [1] Toward Unrivaled Chromatographic Resolving Power in Proteomics: Design and Development of Comprehensive Spatial Three-Dimensional Liquid-Phase Separation Technology
    Eeltink, Sebastiaan
    De Vos, Jelle
    Desmet, Gert
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2024, 17 : 475 - 493
  • [2] Design Guidelines and Kinetic Performance Limits for Spatial Comprehensive Three-Dimensional Chromatography for the Analysis of Intact Proteins
    Themelis, Thomas
    De Vos, Jelle
    Eeltink, Sebastiaan
    ANALYTICAL CHEMISTRY, 2022, 94 (40) : 13737 - 13744
  • [3] Phase behaviour and dynamics of three-dimensional active dumbbell systems
    Caporusso, C. B.
    Negro, G.
    Suma, A.
    Digregorio, P.
    Carenza, L. N.
    Gonnella, G.
    Cugliandolo, L. F.
    SOFT MATTER, 2024, 20 (04) : 923 - 939
  • [4] THREE-DIMENSIONAL SIMULATION OF LIQUID FLOW ON A SIEVE TRAY UNDER DIFFERENT INCLINATIONS
    Zhang Ping
    Jin Dan
    Meng Huibo
    Wu Jianhua
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2014, 31 (04) : 905 - 912
  • [5] Bubble-Assisted Three-Dimensional Ensemble of Nanomotors for Improved Catalytic Performance
    Wang, Ben
    Ji, Fengtong
    Yu, Jiangfan
    Yang, Lidong
    Wang, Qianqian
    Zhang, Li
    ISCIENCE, 2019, 19 : 760 - +
  • [6] Assessment of chemical equivalence in herbal materials using chromatographic fingerprints by combination of three similarity indices and three-dimensional kernel density estimation
    Lee, Gwang Jin
    Lee, Jeong Hee
    Park, Jeong Hill
    Kwon, Sung Won
    Lim, Johan
    Lee, Sungim
    Lee, Jeongmi
    ANALYTICA CHIMICA ACTA, 2018, 1037 : 220 - 229
  • [7] STUDY OF THREE-DIMENSIONAL SEPARATION OF BOUNDARY LAYER OVER BLUNT BODIES
    ATMANI R.
    BRIMA A.
    ASKOVIC R.
    JournalofHydrodynamics, 2009, 21 (01) : 100 - 107
  • [8] Study of Three-Dimensional Separation of Boundary Layer Over Blunt Bodies
    R. Atmani
    A. Brima
    R. Askovic
    Journal of Hydrodynamics, 2009, 21 : 100 - 107
  • [9] STUDY OF THREE-DIMENSIONAL SEPARATION OF BOUNDARY LAYER OVER BLUNT BODIES
    Atmani, R.
    Brima, A.
    Askovic, R.
    JOURNAL OF HYDRODYNAMICS, 2009, 21 (01) : 100 - 107
  • [10] Modeling of multicomponent three-dimensional vesicles
    Gera, Prerna
    Salac, David
    COMPUTERS & FLUIDS, 2018, 172 : 362 - 383