Quantitative Fluorescence Spectroscopy in Turbid Media: A Practical Solution to the Problem of Scattering and Absorption

被引:25
作者
Chen, Yao [1 ]
Chen, Zeng-Ping [1 ]
Yang, Jing [1 ]
Jin, Jing-Wen [1 ]
Zhang, Juan [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
INTRINSIC FLUORESCENCE; REFLECTANCE SPECTRA; IN-VIVO; TISSUE; AUTOFLUORESCENCE; SAMPLES; SKIN; PIGMENTATION; RECOVERY; CALCIUM;
D O I
10.1021/ac302815e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of practically unavoidable scatterers and background absorbers in turbid media such as biological tissue or cell suspensions can significantly distort the shape and intensity of fluorescence spectra of fluorophores and, hence, greatly hinder the in situ quantitative determination of fluorophores in turbid media. In this contribution, a quantitative fluorescence model (QFM) was proposed to explicitly model the effects of the scattering and absorption on fluorescence measurements. On the basis of the proposed model, a calibration strategy was developed to remove the detrimental effects of scattering and absorption and, hence, realize accurate quantitative analysis of fluorophores in turbid media. A proof-of-concept model system, the determination of free Ca2+ in turbid media using Fura-2, was utilized to evaluate the performance of the proposed method. Experimental results showed that QFM can provide quite precise concentration predictions for free Ca2+ in turbid media with an average relative error of about 7%, probably the best: results ever achieved for turbid media without the use of advanced optical technologies. QFM has not only good performance but also simplicity of implementation. It does not require characterization of the light scattering properties of turbid media, provided that the light scattering and absorption properties of the test samples are reasonably close to those of the calibration samples. QFM can be developed and extended in many application areas such as ratiometric fluorescent sensors for quantitative live cell imaging.
引用
收藏
页码:2015 / 2020
页数:6
相关论文
共 33 条
[1]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[2]   Recovery of turbidity free fluorescence from measured fluorescence: an experimental approach [J].
Biswal, NC ;
Gupta, S ;
Ghosh, N ;
Pradhan, A .
OPTICS EXPRESS, 2003, 11 (24) :3320-3331
[3]   A review of attenuation correction techniques for tissue fluorescence [J].
Bradley, RS ;
Thorniley, MS .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2006, 3 (06) :1-13
[4]   Correction of tissue autofluorescence by reflectance spectrum [J].
Chen, XD ;
Xie, HB ;
Xu, Z ;
Yu, DY .
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 :441-444
[5]   Extracting chemical information from spectral data with multiplicative light scattering effects by optical path-length estimation and correction [J].
Chen, Zeng-Ping ;
Morris, Julian ;
Martin, Elaine .
ANALYTICAL CHEMISTRY, 2006, 78 (22) :7674-7681
[6]   The NADH fluorescence/UV reflectance ratio provides a semi-quantitative measure for NADH fluorometry of blood perfused rat heart [J].
Coremans, JMCC ;
Ince, C ;
Bruining, HA ;
Puppels, GJ .
OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING II, PROCEEDINGS OF, 1996, 2927 :180-191
[7]   RELATION BETWEEN FLUORESCENCE-SPECTRA OF DILUTE AND TURBID SAMPLES [J].
DURKIN, AJ ;
JAIKUMAR, S ;
RAMANUJAM, N ;
RICHARDSKORTUM, R .
APPLIED OPTICS, 1994, 33 (03) :414-423
[8]  
Durkin AJ, 1996, LASER SURG MED, V19, P75, DOI 10.1002/(SICI)1096-9101(1996)19:1<75::AID-LSM9>3.0.CO
[9]  
2-N
[10]  
Finlay JC, 2001, PHOTOCHEM PHOTOBIOL, V73, P54, DOI 10.1562/0031-8655(2001)073<0054:PBAPIS>2.0.CO