Purpose: To compile a survey of complications during and after Descemet's stripping with automated endothelial keratoplasty (DSAEK) in 118 eyes conducted by cornea subspecialists at a single academic center. Design: Retrospective case series. Participants: One hundred eighteen eyes undergoing DSAEK in 99 patients. Methods: Outcomes of DSAEK performed in 118 eyes by 10 surgeons were reviewed retrospectively. Sixty-four eyes had pseudophakic bullous keratopathy. Forty-one had Fuchs' endothelial dystrophy and cataract. Three had aphakic bullous keratopathy. In 10 eyes, previous DSAEK performed at the same institution failed. Complications of DSAEK were noted from the intraoperative and postoperative periods. Detached DSAEK grafts were repositioned, rebubbled, or both immediately after diagnosis of this complication. Main Outcome Measures: Intraoperative and postoperative complications of DSAEK. Results: Graft detachment was the most common type of complication encountered. In 27 (23%) of 118 eyes, graft detachments were observed. Twenty-five eyes with detached grafts successfully were repositioned or rebubbled after surgery, or both. In 1 eye, a previously detached graft reattached spontaneously. In 1 aphakic eye, the graft detached into the vitreous cavity. In 17 eyes, successful reattachment of the cornea occurred (68%). Twenty-one of the 118 eyes were considered to have failed DSAEK, meaning that persistent edema was present after DSAEK. Seven (6%) demonstrated graft rejection. In 5 eyes (4%), retinal detachment (RD) developed. In 6 (5%), cystoid macular edema developed. In 1 aphakic patient, an air bubble could not be maintained during surgery, and sulfur hexafluoride was injected into the anterior chamber. In 1 eye (1 %), epithelial ingrowth developed. One eye (1 %) demonstrated blood in the graft interface. In 1 eye (1 %), a limited intraoperative suprachoroidal hemorrhage occurred. Two eyes (2%) had pupillary block after surgery that resolved with removal of the air bubble. Conclusions: Descemet's stripping with automated endothelial keratoplasty has become a popular and effective treatment for corneal endothelial dysfunction, but complications resulting from DSAEK do occur. Graft detachment is the most common complication, but postoperative repositioning or rebubbling, or both, allow for graft reattachment in most cases. Other complications found in this series were graft failure, graft rejection, cystoid macular edema, RD, suprachoroidal hemorrhage, and pupillary block. Retained Descemet's membrane and epithelial ingrowth, are potential causes of dislocation.
引用
收藏
页码:1517 / 1524
页数:8
相关论文
共 16 条
  • [1] Corneal transplant rejection rate and severity after endothelial keratoplasty
    Allan, Bruce D. S.
    Terry, Mark A.
    Price, Francis W., Jr.
    Price, Marianne O.
    Griffin, Neil B.
    Claesson, Margareta
    [J]. CORNEA, 2007, 26 (09) : 1039 - 1042
  • [2] New triple procedure: Descemet's stripping and automated endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation
    Covert, Douglas J.
    Koenig, Steven B.
    [J]. OPHTHALMOLOGY, 2007, 114 (07) : 1272 - 1277
  • [3] Descemet-stripping automated endothelial keratoplasty
    Gorovoy, Mark S.
    [J]. CORNEA, 2006, 25 (08) : 886 - 889
  • [4] GROAT B, DESCEMET STRIPPING A
  • [5] Early results of small-incision Descemet's stripping and automated endothelial keratoplasty
    Koenig, Steven B.
    Covert, Douglas J.
    [J]. OPHTHALMOLOGY, 2007, 114 (02) : 221 - 226
  • [6] Diagnosis of residual Descemet's membrane after Descemet's stripping endothelial keratoplasty with anterior segment optical coherence tomography
    Kymionis, George D.
    Suh, Leejee H.
    Dubovy, Sander R.
    Yoo, Sonia H.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) : 1322 - 1324
  • [7] Experience and 12-month results of Descemet-stripping endothelial keratoplasty (DSEK) with a small-incision technique
    Mearza, Ali A.
    Qureshi, Muhammad A.
    Rostron, Chad K.
    [J]. CORNEA, 2007, 26 (03) : 279 - 283
  • [8] A surgical technique for posterior lamellar keratoplasty
    Melles, GRJ
    Eggink, FAGJ
    Lander, F
    Pels, E
    Rietveld, FJR
    Beekhuis, WH
    Binder, PS
    [J]. CORNEA, 1998, 17 (06) : 618 - 626
  • [9] Sutureless, posterior lamellar keratoplasty - A case report of a modified technique
    Melles, GRJ
    Lander, F
    Nieuwendaal, C
    [J]. CORNEA, 2002, 21 (03) : 325 - 327
  • [10] Price FW, 2005, J REFRACT SURG, V21, P339