Direct detection of phoxim in water by two-dimensional correlation near-infrared spectroscopy combined with partial least squares discriminant analysis

被引:17
作者
Gu, Congying [1 ,2 ]
Xiang, Bingren [1 ]
Xu, Jianping [3 ]
机构
[1] China Pharmaceut Univ, Ctr Instrumental Anal, Key Lab Drug Qual Control & Pharmacovigilance, Minist Educ, Nanjing 210009, Jiangsu, Peoples R China
[2] China Pharmaceut Univ, Dept Organ Chem, Nanjing 210009, Jiangsu, Peoples R China
[3] Zhongjian Pharmaceut Co Ltd, Zhongshan, Guangdong, Peoples R China
关键词
Phoxim; Water; Two-dimensional correlation; Near-infrared spectroscopy; Partial least squares discriminant analysis; PERFORMANCE LIQUID-CHROMATOGRAPHY; PATTERN-RECOGNITION; MASS-SPECTROMETRY; CHEMOMETRICS; MICROEXTRACTION; RESIDUES; SAMPLES; METHYL; RAMAN; EGGS;
D O I
10.1016/j.saa.2012.06.046
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This paper has established a simple method to detect directly phoxim in water. In the light of two-dimensional correlation analysis, the band of wavenumber for near-infrared spectroscopy of the model is between 5364.8 and 7552.9 cm(-1), the rate of accuracy for partial least squares discriminant analysis to calibration set (n = 149) is 100%, prediction set (n = 75) is 93.3% and the overall rate of accuracy for all the samples is 97.8% under the limit of detection 1 mu g ml(-1) owing to the spectra preprocessing by standard normal variate transformation and multiplicative scatter correction. It is made clear that this method (two-dimensional correlation analysis combined with partial least squares discriminant analysis) is effective to detect directly phoxim in water. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:594 / 599
页数:6
相关论文
共 25 条
[1]  
Agnat H., 2001, CHEMOM INTELL LAB SY, V55, P23
[2]   Biodiesel classification by base stock type (vegetable oil) using near infrared spectroscopy data [J].
Balabin, Roman M. ;
Safieva, Ravilya Z. .
ANALYTICA CHIMICA ACTA, 2011, 689 (02) :190-197
[3]   Calibration in non-linear near infrared reflectance spectroscopy:: a comparison of several methods [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pagès, J .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :207-214
[4]   SOME CONSIDERATIONS ON APPARENT DEVIATIONS FROM LAMBERT-BEERS LAW [J].
BUIJS, K ;
MAURICE, MJ .
ANALYTICA CHIMICA ACTA, 1969, 47 (03) :469-&
[5]   Pattern recognition of gas chromatography mass spectrometry of human volatiles in sweat to distinguish the sex of subjects and determine potential discriminatory marker peaks [J].
Dixon, Sarah J. ;
Xu, Yun ;
Brereton, Richard G. ;
Soini, Helena A. ;
Novotny, Milos V. ;
Oberzaucher, Elisabeth ;
Grammer, Karl ;
Penn, Dustin J. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2007, 87 (02) :161-172
[6]  
Fernando C., 2006, ENVIRON SCI POLICY, V9, P685
[7]   Differential mutagenic response of Salmonella typhimurium to the plant-metabolized organophosphorus insecticides, phoxim and azinphos methyl [J].
Gomez-Arroyo, Sandra ;
Cortes-Eslava, Josefina ;
Villalobos-Pletrini, Rafael ;
Calderon-Segura, Maria Elena ;
Flores-Marquez, Ana Rosa ;
Espinosa-Aguirre, Jesus Javier .
TOXICOLOGY IN VITRO, 2007, 21 (05) :950-955
[8]   Use of continuous-flow microextraction and liquid chromatography for determination of phoxim in water samples [J].
Guo, L ;
Liang, P ;
Zhang, TZ ;
Liu, Y ;
Liu, S .
CHROMATOGRAPHIA, 2005, 61 (9-10) :523-526
[9]   The robust normal variate transform for pattern recognition with near-infrared data [J].
Guo, Q ;
Wu, W ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :87-103
[10]   Determination of phoxim residues in eggs by using high-performance liquid chromatography diode array detection after treatment of stocked housing facilities for the poultry red mite (Dermanyssus gallinae) [J].
Hamscher, G. ;
Priess, B. ;
Nau, H. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :330-335