Direct profiling of endogenous metabolites in rat brain microdialysis samples by capillary electrophoresis-mass spectrometry with on-line preconcentration

被引:20
作者
van Mever, Marlien [1 ]
Segers, Karen [1 ,2 ,3 ]
Drouin, Nicolas [1 ]
Guled, Faisa [1 ]
Vander Heyden, Yvan [2 ]
Van Eeckhaut, Ann [3 ]
Hankemeier, Thomas [1 ]
Ramautar, Rawi [1 ]
机构
[1] Leiden Univ, Leiden Acad Ctr Drug Res, Biomed Microscale Analyt, Leiden, Netherlands
[2] Vrije Univ Brussel, Dept Analyt Chem Appl Chemometr & Mol Modelling, Brussels, Belgium
[3] Vrije Univ Brussel, Ctr Neurosci, Dept Pharmaceut Chem Drug Anal & Drug Informat, Brussels, Belgium
关键词
Capillary electrophoresis; Direct analysis; Mass spectrometry; Metabolic profiling; Rat brain microdialysate; AMINO-ACIDS; OPTIMIZATION; METABOLOMICS; URINE;
D O I
10.1016/j.microc.2020.104949
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metabolic profiling of body fluids from small animal models is often used in (translational) biological studies in order to obtain insight into the underlying molecular mechanisms of (complex) diseases. An example is the use of brain microdialysis samples from rats to study neurological disorders by means of a metabolomics approach. From an analytical point of view, the profiling of (endogenous) metabolites in rat brain microdialysates is challenging because of the limited sample volume for both sample preparation and injection, notably in longitudinal studies. In this work, we have assessed the analytical performance of capillary electrophoresis-mass spectrometry (CE-MS) for the direct profiling of endogenous metabolites in rat brain microdialysates, i.e. without using any sample preparation or derivatization. An on-line preconcentration procedure with sample stacking, which was fully compatible with the high-salt concentration in microdialysates, was used to significantly improve the detection sensitivity of the CE-MS method for metabolic profiling. A response surface methodology, applying a Box-Behnken design, was considered to determine the optimal conditions for preconcentration. A linear response (R-2 > 0.99) for selected metabolites in the concentration range from 0.05 to 10 mu M was obtained in perfusate samples. Interday RSD values for peak area and migration time were 2.6-19% and below 3.8%, respectively. Limits of detection ranged from 11 to 284 nM when employing an injection volume of about 291 nL, corresponding to 17% of the total capillary volume. The utility of the CE-MS approach was demonstrated by the direct profiling of endogenous metabolites in rat brain microdialysates. At least 48 compounds could be analyzed of which 25 were provisionally identified and quantified.
引用
收藏
页数:10
相关论文
共 42 条
  • [1] [Anonymous], 2001, CURR PROTOC NEUROSCI
  • [2] Analysis of serotonin in brain microdialysates using capillary electrophoresis and native laser-induced fluorescence detection
    Benturquia, N
    Couderc, F
    Sauvinet, V
    Orset, C
    Parrot, S
    Bayle, C
    Renaud, B
    Denoroy, L
    [J]. ELECTROPHORESIS, 2005, 26 (06) : 1071 - 1079
  • [3] Response surface methodology (RSM) as a tool for optimization in analytical chemistry
    Bezerra, Marcos Almeida
    Santelli, Ricardo Erthal
    Oliveira, Eliane Padua
    Villar, Leonardo Silveira
    Escaleira, Luciane Amlia
    [J]. TALANTA, 2008, 76 (05) : 965 - 977
  • [4] Sensitive targeted methods for brain metabolomic studies in microdialysis samples
    Bongaerts, Jana
    De Bundel, Dimitri
    Mangelings, Debby
    Smolders, Ilse
    Heyden, Yvan Vander
    Van Eeckhaut, Ann
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 161 : 192 - 205
  • [5] Metabolomic analysis of mouse prefrontal cortex reveals upregulated analytes during wakefulness compared to sleep
    Bourdon, Allen K.
    Spano, Giovanna Maria
    Marshall, William
    Bellesi, Michele
    Tononi, Giulio
    Serra, Pier Andrea
    Baghdoyan, Helen A.
    Lydic, Ralph
    Campagna, Shawn R.
    Cirelli, Chiara
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [6] Bowser MT, 2001, ELECTROPHORESIS, V22, P3668, DOI 10.1002/1522-2683(200109)22:17<3668::AID-ELPS3668>3.0.CO
  • [7] 2-M
  • [8] Chefer Vladimir I, 2009, Curr Protoc Neurosci, VChapter 7, DOI 10.1002/0471142301.ns0701s47
  • [9] The application of Box-Behnken-Design in the optimization of HPLC separation of fluoroquinolones
    Czyrski, Andrzej
    Sznura, Justyna
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] DERRINGER G, 1980, J QUAL TECHNOL, V12, P214, DOI 10.1080/00224065.1980.11980968