Successful surgical treatment of an infected right coronary artery aneurysm-to-right ventricle fistula after sirolimus-eluting stent implantation

被引:12
作者
Kishida, Ken [1 ,2 ]
Nakaoka, Hajime [1 ]
Sumitsuji, Satoru [1 ]
Nakatsuji, Hideaki [1 ]
Ihara, Madoka [1 ]
Nojima, Yuhei [1 ]
Shimomura, Iichiro [2 ]
Nagai, Yoshiyuki [1 ]
机构
[1] Rinku Gen Med Ctr, Dept Cardiol, Suita, Osaka, Japan
[2] Osaka Univ, Grad Sch Med, Dept Metab Med, Suita, Osaka, Japan
关键词
sirolimus-eluting stent; infected aneurysm; fistula; local immunosuppression;
D O I
10.2169/internalmedicine.46.6459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The development of infected coronary aneurismal fistula following stenting seems exceedingly rare. A sirolimus-eluting stent (SES) was implanted in a 70-year-old male patient for acute coronary syndrome. His fever persisted despite treatment with adapted antibiotics. Coronary angiography and 16-multidetector row computed tomography demonstrated the huge right coronary aneurysm forming a fistula to the right ventricle. The aneurysm was excised by surgical treatment. Histopathological examination of the resected mass revealed leucocyte infiltration at the stent site, which lead to the diagnosis of mycotic aneurysm. SESs may play a potential role in locally blunting the innate response to bacterial agents.
引用
收藏
页码:865 / 871
页数:7
相关论文
共 35 条
[31]   5-Year Clinical Outcomes of the ARTS II (Arterial Revascularization Therapies Study II) of the Sirolimus-Eluting Stent in the Treatment of Patients With Multivessel De Novo Coronary Artery Lesions [J].
Serruys, Patrick W. ;
Onuma, Yoshinobu ;
Garg, Scot ;
Vranckx, Pascal ;
De Bruyne, Bernard ;
Morice, Marie-Claude ;
Colombo, Antonio ;
Macaya, Carlos ;
Richardt, Gert ;
Fajadet, Jean ;
Hamm, Christian ;
Schuijer, Monique ;
Rademaker, Tessa ;
Wittebols, Kristel ;
Stoll, Hans Peter .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (11) :1093-1101
[32]   Stent Thrombosis and Bleeding Complications After Implantation of Sirolimus-Eluting Coronary Stents in an Unselected Worldwide Population A Report From the e-SELECT (Multi-Center Post-Market Surveillance) Registry [J].
Urban, Philip ;
Abizaid, Alexandre ;
Banning, Adrian ;
Bartorelli, Antonio L. ;
Baux, Ana Cebrian ;
Dzavik, Vladimir ;
Ellis, Stephen ;
Gao, Runlin ;
Holmes, David ;
Jeong, Myung Ho ;
Legrand, Victor ;
Neumann, Franz-Josef ;
Nyakern, Maria ;
Spaulding, Christian ;
Worthley, Stephen .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (13) :1445-1454
[33]   Three-year clinical outcome of percutaneous treatment of bifurcation lesions in multivessel coronary artery disease with the sirolimus-eluting stent: insights from the Arterial Revascularisation Therapies Study, part II (ARTS II) [J].
Routledge, Helen C. ;
Lefevre, Thierry ;
Colombo, Antonio ;
Oldroyd, Keith G. ;
Hamm, Christian W. ;
Guagliumi, Giulio ;
von Scheidt, Wolfgang ;
Guetta, Victor ;
Ruzyllo, Witold ;
Wittebols, Kristel ;
Goedhart, Dick M. ;
Serruys, Patrick W. .
EUROINTERVENTION, 2009, 5 (02) :190-196
[34]   Comparison of 5-Year Outcomes in Patients With and Without Unprotected Left Main Coronary Artery Disease After Treatment With Sirolimus-Eluting Stents Insights From the j-Cypher Registry [J].
Toyofuku, Mamoru ;
Kimura, Takeshi ;
Morimoto, Takeshi ;
Hayashi, Yasuhiko ;
Shiode, Nobuo ;
Nishikawa, Hideo ;
Nakao, Koichi ;
Shirota, Kinya ;
Kawai, Kazuya ;
Hiasa, Yoshikazu ;
Kadota, Kazushige ;
Nozaki, Yoichi ;
Isshiki, Takaaki ;
Sone, Takahito ;
Mitsudo, Kazuaki .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (07) :654-663
[35]   A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results [J].
Xu Bo ;
Dou Ke-fei ;
Han Ya-ling ;
Lue Shu-zheng ;
Yang Yue-jin ;
Huo Yong ;
Wang Le-feng ;
Chen Yun-dai ;
Wang Hai-chang ;
Li Wei-min ;
Chen Ji-yan ;
Wang Lei ;
Wang Yong ;
Ge Jun-bo ;
Li Wei ;
Gao Run-lin .
CHINESE MEDICAL JOURNAL, 2011, 124 (06) :811-816