Correction for the effect of soil moisture on in situ XRF analysis using low-energy background

被引:51
作者
Bastos, R. O. [1 ]
Melquiades, F. L. [1 ]
Biasi, G. E. V. [1 ]
机构
[1] Univ Estadual Centro Oeste, Dept Phys, BR-85015430 Guarapuava, PR, Brazil
关键词
in situ XRF; soil; moisture; background; RAY-FLUORESCENCE ANALYSIS;
D O I
10.1002/xrs.2397
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
X-ray fluorescence (XRF) analyses are affected by many matrix and geometrical factors that, generally, are possible to handle in laboratory conditions. However, when in situ analyses are considered, constraints in the measurement conditions make more difficult to handle some factors, such as moisture, affecting the measurement accuracy. Efforts have been made to correct some of the effects by inserting some steps in the sample preparation process. The problem is that each step added in this process, aiming a better precision and accuracy, makes the in situ measurement harder and longer to accomplish, influencing negatively the intrinsic advantages of the in situ measurement. In this work, we propose a method to correct the effect of soil moisture on in situ XRF analysis using low-energy background. The method demands a simple calibration, after which a long drying procedure is not necessary before measuring the samples. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 12 条
[1]   X-ray fluorescence analysis of geological samples: exploring the ellect ot sample thickness on the accuracy of results [J].
Al-Merey, R ;
Karajou, J ;
Issa, H .
APPLIED RADIATION AND ISOTOPES, 2005, 62 (03) :501-508
[2]  
[Anonymous], 2007, METHOD 6200 FIELD PO
[3]   The influence of scattering processes in quantitative X-ray fluorescence analysis [J].
Bos, M ;
Vrielink, JAM .
ANALYTICA CHIMICA ACTA, 2005, 545 (01) :92-98
[4]   Influence of and correction for moisture in rocks, soils and sediments on in situ XRF analysis [J].
Ge, LQ ;
Lai, WC ;
Lin, YC .
X-RAY SPECTROMETRY, 2005, 34 (01) :28-34
[5]   WinXCom - a program for calculating X-ray attenuation coefficients [J].
Gerward, L ;
Guilbert, N ;
Jensen, KB ;
Levring, H .
RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) :653-654
[6]   X-ray absorption in matter. reengineering XCOM [J].
Gerward, L ;
Guilbert, N ;
Jensen, KB ;
Levring, H .
RADIATION PHYSICS AND CHEMISTRY, 2001, 60 (1-2) :23-24
[7]   Recent advances in portable X-ray fluorescence spectrometry [J].
Hou, XD ;
He, YH ;
Jones, BT .
APPLIED SPECTROSCOPY REVIEWS, 2004, 39 (01) :1-25
[8]  
Hubbell J.H., 1987, XCOM PHOTON CROSS SE
[9]   Comparison of XRF and FAAS methods in analysing CCA contaminated soils [J].
Mäkinen, E ;
Korhonen, M ;
Viskari, EL ;
Haapamäki, S ;
Järvinen, M ;
Lu, L .
WATER AIR AND SOIL POLLUTION, 2006, 171 (1-4) :95-110
[10]  
Melquiades F. L., 2011, AIP C P, V1352, P317