Suppression of the cardiopulmonary resuscitation artefacts using the instantaneous chest compression rate extracted from the thoracic impedance

被引:47
作者
Aramendi, E. [1 ]
Ayala, U. [1 ]
Irusta, U. [1 ]
Alonso, E. [1 ]
Eftestol, T. [2 ]
Kramer-Johansen, J. [3 ,4 ]
机构
[1] Univ Basque Country, Elect & Telecommun Dept, Bilbao 48013, Spain
[2] Univ Stavanger, Dept Elect Engn & Comp Sci, N-4036 Stavanger, Norway
[3] Oslo Univ Hosp HF, Expt Med Res Inst, N-0426 Oslo, Norway
[4] Oslo Univ Hosp HF, Dept Anaesthesiol, N-0426 Oslo, Norway
关键词
Transthoracic impedance; Compression rate; CPR artefact suppression; AUTOMATIC EXTERNAL DEFIBRILLATORS; VENTRICULAR-FIBRILLATION ECG; CPR ARTIFACTS; REMOVAL; QUALITY; PERFORMANCE; DEPTH;
D O I
10.1016/j.resuscitation.2011.11.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim: To demonstrate that the instantaneous chest compression rate can be accurately estimated from the transthoracic impedance (TTI), and that this estimated rate can be used in a method to suppress cardiopulmonary resuscitation (CPR) artefacts. Methods: A database of 372 records, 87 shockable and 285 non-shockable, from out-of-hospital cardiac arrest episodes, corrupted by CPR artefacts, was analysed. Each record contained the ECG and TTI obtained from the defibrillation pads and the compression depth (CD) obtained from a sternal CPR pad. The chest compression rates estimated using TTI and CD were compared. The CPR artefacts were then filtered using the instantaneous chest compression rates estimated from the TTI or CD signals. The filtering results were assessed in terms of the sensitivity and specificity of the shock advice algorithm of a commercial automated external defibrillator. Results: The correlation between the mean chest compression rates estimated using TTI or CD was r = 0.98 (95% confidence interval, 0.97-0.98). The sensitivity and specificity after filtering using CD were 95.4% (88.4-98.6%) and 87.0% (82.6-90.5%), respectively. The sensitivity and specificity after filtering using TTI were 95.4% (88.4-98.6%) and 86.3% (81.8-89.9%), respectively. Conclusions: The instantaneous chest compression rate can be accurately estimated from TTI. The sensitivity and specificity after filtering are similar to those obtained using the CD signal. Our CPR suppression method based exclusively on signals acquired through the defibrillation pads is as accurate as methods based on signals obtained from CPR feedback devices. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:692 / 698
页数:7
相关论文
共 32 条
[1]   CPR artifact removal from human ECG using optimal multichannel filtering [J].
Aase, SO ;
Eftestol, T ;
Husoy, JH ;
Sunde, K ;
Steen, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (11) :1440-1449
[2]   Compression depth estimation for CPR quality assessment using DSP on accelerometer signals [J].
Aase, SO ;
Myklebust, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (03) :263-268
[3]  
Aramendi E, 2010, RESUSCITATION, V81, pS52
[4]   Rhythm discrimination during uninterrupted CPR using motion artifact reduction system [J].
Berger, Ronald D. ;
Palazzolo, James ;
Halperin, Henry .
RESUSCITATION, 2007, 75 (01) :145-152
[5]   A method to remove CPR artefacts from human ECG using only the recorded ECG [J].
de Gauna, Sofia Ruiz ;
Ruiz, Jesus ;
Irusta, Unai ;
Aramendi, Elisabete ;
Eftestol, Trygve ;
Kramer-Johansen, Jo .
RESUSCITATION, 2008, 76 (02) :271-278
[6]   European Resuscitation Council Guidelines for Resuscitation 2010 Section 4 Adult advanced life support [J].
Deakin, Charles D. ;
Nolan, Jerry P. ;
Soar, Jasmeet ;
Sunde, Kjetil ;
Koster, Rudolph W. ;
Smith, Gary B. ;
Perkins, Gavin D. .
RESUSCITATION, 2010, 81 (10) :1305-1352
[7]   Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest [J].
Edelson, Dana P. ;
Abella, Benjamin S. ;
Kramer-Johansen, Jo ;
Wik, Lars ;
Myklebust, Helge ;
Barry, Anne M. ;
Merchant, Raina M. ;
Vanden Hoek, Terry L. ;
Steen, Petter A. ;
Becker, Lance B. .
RESUSCITATION, 2006, 71 (02) :137-145
[8]   Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG [J].
Eilevstjonn, J ;
Eftestol, T ;
Aase, SO ;
Myklebust, H ;
Husoy, JH ;
Steen, PA .
RESUSCITATION, 2004, 61 (02) :131-141
[9]  
GEDDES L A, 1971, JAAMI Journal of the Association for the Advancement of Medical Instrumentation, V5, P13
[10]   Development of the probability of return of spontaneous circulation in intervals without chest compressions during out-of-hospital cardiac arrest: an observational study [J].
Gundersen, Kenneth ;
Kvaloy, Jan Terje ;
Kramer-Johansen, Jo ;
Steen, Petter Andreas ;
Eftestol, Trygve .
BMC MEDICINE, 2009, 7